9.2 Understanding the general operation
The generator GUARDIAN SC6 is an equipment designed to support photovoltaic
installations. The generator will provide power when the solar energy is not
enough.
Our generator has been designed for an automatic startup and stop commanded
by a inverter/charger.
The inverter / charger of the installation is the responsible equipment for detecting
the battery charge low level and sends a startup signal to the generator. Similarly,
the inverter / charger detects when the batteries are recharged and sends a stop
signal to the generator.
Not all inverter / chargers are prepared to work with generators, consult the
manufacturer of the inverter, if you have any doubts.
230V power input connection:
The automatic mode of the generator consumes
very little power just for being active. This consumption is fed from the generator's
battery, it is essential to connect the 230V power input since otherwise the battery
would be discharged within a few hours.
This connection comes from the 230 V inverter output and connects to the “input
power 230V
” on the generator's control panel. Thanks to this power a battery
charger located in the generator control panel is active; if the battery of the
generator has low charge it will be recharged through this energy.
Note: Not feeding the 230 V power input means the discharge of the battery in
a few hours, and soon it will become a severe discharge resulting in a damaged
and unusable battery.
INVERTER
CHARGER