68
Parameter
Para. No.
(Hex)
Parameter value & option
Factory
default
Factory
default
Supp.
0x06: Data+Suf2
0x07: Data + Suf1 + Suf2
Serial interface
Baud Rate
0x9C
0x03: 1200
0x04: 2400
0x05: 4800
0x06: 9600
0x07: 19200
0x08: 38400
0x09: 57600
0x0A: 115200
0x06
(9600)
Same as left
Yes
Parity 0x9E
0x00: Odd
0x01: Even
0x04: None
0x04 (None)
Same as left
Yes
Software Handshaking
0x9F
0: Disable
1: Enable
1 (Enable)
Same as left
Yes
Decode Data Packet
Format
0xEE
0: Raw
1: Packeted
0 (Raw)
Same as left
Yes
Host Serial Response
Time-out
0x9B
0x00~0x63 (unit 100ms)
0x14 (2 sec)
Same as left
Yes
Stop Bit
0x9D
1: One
2: Two
1 (One)
Same as left
Yes
Inter-character Delay
0x6E
00~99 (unit 1ms)
[1]
0 (0 ms)
Same as left
Yes
Host Character Time-out 0xEF
00~99(unit 10ms)
[1]
0x14 (200
ms)
Same as left
Yes
Event reporting
Decode Event
0xF0
0x00
0: Disable
1: Enable
0 (Disable)
Same as left
No
Boot Up Event
0xF0
0x02
0: Disable
1: Enable
0 (Disable)
Same as left
Yes
Parameter Event
0xF0
0x03
0: Disable
1: Enable
0 (Disable)
Same as left
No
Note 1: If Trioptic Code 39 read is set Enable, Code 39 read is forced Enable.
Note 2: If Code 39 read is set Disable, Trioptic Code 39 read is forced Disable.
Reserved
FS01 & MS3391-L