47
6-20 Code 11
Read:
Format
Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)
Check digit verification: The check digit is presented as the sum module 11 of all data digits.
Check digit transmission: By setting Enable, check digit 1 and check digit 2 will be transmitted upon your
selected check digit verification method.
Max./Min. code length: Refer to Max./Min. code length of Code 39.
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Parameter name
Para. code Para. option
Para. value
Parameter (Para. No.)
Para.
value
Read
0x08 0x99
Disable
Enable
00*
01
Code 11 (0x0A)
00*
01
Check digit verification
0x08 0x9A
Disable
One digit
Two digit
00
01*
02
Code 11 Check Digit Verification
(0x34)
00*
01
02
Check digit transmission
0x08 0x9B
Disable
Enable
00*
01
Transmit Code 11 Check Digit
(0x2F)
00*
01
Max. code length
0x08 0x9C
00-99
00-99
99*
Min. code length
0x08 0x9D
00-99
00-99
04*
Set Lengths for Code 11
L1: (0x1C)
L2: (0x1D)
Note1
04*
55*
Code ID setting
0x08 0x9E
00-FF
16
(ASCII)
00-FF
16
<V>*
Code11_CodeIDSetting
(0xF2 0x80)
<H>*
Insert group selection
0x08 0x9F
00-44
00-44
00*
Code11_InsertGroupSelection
(0xF2 0x81)
00-44
00*
Reserved
0x08 0xA0
-
-
Reserved
FS01 & MS3391-L