OPERATING MANUAL

 

WARNING

In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical 
breaker or disconnect the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.

• Unit smells of something burning or emits smoke
• Water leaks from the unit

Following symptoms do not indicate the product malfunction, but they are normal functions or characteristics of this product.

Symptom

Cause

See page

Operation is delayed after 
restart.

To prevent blowout of the fuse, the compressor will not operate during the protection circuit is working 
for about 3 minutes after sudden OFF

ON operation of the power supply.

Noise is heard.

• During the operation or immediately after stopping the air conditioner, refrigerant 

fl

 owing sound 

may be heard. And it is particularly noticeable for 2–3 minutes after starting operation.

• During the operation, a slight squeaking sound produced by the minute expansion and contraction 

of the front panel caused by temperature change may be heard.

During heating operation, a sizzling sound produced by the automatic defrosting operation may be 
heard.

5

Smell coming from the unit.

Absorbed room smell generated from interior textile, furniture, or cigarette smoke into the air condi-
tioner may be emitted.

Mist or steam is emitted from 
the unit.

In COOL or DRY mode, a thin mist generated by condensation formed with sudden cooling process 
may be emitted.

During heating operation, the fan built-in the outdoor unit may stops and rising steam generated by 
the automatic defrosting operation may be seen.

5

Air

fl

 ow is weak or stops.

• Immediately after the heating operation is started, the fan speed stays temporarily very low to warm 

up the internal parts of the unit.

• In HEAT mode, the outdoor unit stops and the indoor unit operates at very low fan speed if the 

room temperature rises above the set temperature.

In HEAT mode, the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic 
defrosting operation while the OPERATION indicator is 

fl

 ashing.

5

In DRY mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop 
from time to time.

When the fan speed is set to “QUIET”, the fan rotates at very low speed and the air

fl

 ow is reduced.

In COOL mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped.

3

When monitoring operation is performed in AUTO mode, the fan rotates at very low speed.

When multiple units are operated in following combination of different operation modes in a multi-
type air conditioning system, the indoor unit operated afterward stops and the OPERATION indicator 

fl

 ashes.

• HEAT mode and COOL mode (or DRY mode)
• HEAT mode and FAN mode

5

Outdoor unit emits water.

During heating operation, the outdoor unit may emit water generated by the automatic defrosting 
operation.

When the 

fi

 lter sign is set, the LED lamp may 

fl

 ash. In this case, please refer to “Filter Indicator Reset (Special setting)”.

Before you call for or request servicing, troubleshoot a problem by performing following checks:

Symptom

Diagnostic

See page

Does not operate at all.

 Has the circuit breaker been turned off?

 Has there been a power outage?

 Has a fuse blown out or the circuit breaker been tripped?

 Is the timer operating? 

5

Poor cooling or heating perfor-
mance.

 Is the air 

fi

 lter dirty? 

6

 Is the intake grille or outlet port of indoor unit blocked?

 Is the room temperature adjusted appropriately?

3

 Is a window or door left opened?

 Is direct or strong sunlight shinning into the room in cooling operation?

  Are there other heating apparatus or computers operating, or too many people in the room in cool-

ing operation?

  Is the fan speed set to “QUIET”?

When the fan speed setting is set to “QUIET”, noise reduction is prioritized and the air-conditioning 
performance may become lower. If the volume of provided air

fl

 ow is not agreeable to your prefer-

ence, set the fan speed to “LOW” or higher fan speed.

4

The unit operates differently 
from the remote controller 
setting.

 Are the batteries used in the remote controller exhausted?

 Are the batteries used in the remote controller loaded properly?

3

Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.

• The problem persists even if you perform these checks or diagnostics.
• The OPERATION indicator and TIMER indicator blink while the ECONOMY indicator is blinking fast.

Troubleshooting

9333003047-04_OM.indb   8

9333003047-04_OM.indb   8

12/19/2017   5:10:41 PM

12/19/2017   5:10:41 PM

Содержание ASG7MI-LM

Страница 1: ...ling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m 40 in away from either the indoor unit or outdoor unit Disconnect all the power supply when...

Страница 2: ...Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in ver...

Страница 3: ... control range noticeably shortens replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 Start Stop button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minut...

Страница 4: ...topping In FAN mode either of swing direction 1 3 or 4 7 is performed in accordance with the vertical airflow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control...

Страница 5: ...the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the heating operation the outdoor unit will stop...

Страница 6: ...ft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise C...

Страница 7: ... have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts thoroughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In...

Страница 8: ...rates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation is performed in AUTO mode the fan rotates at very low speed When multiple units are operated in follo...

Отзывы: