General ASG7MI-LM Скачать руководство пользователя страница 2

En-2

OPERATING MANUAL

1 Intake 

grille

Before starting operation, make sure that the intake grille has been 
shut completely. Incomplete closing might have an effect on the 
proper working or performance of the product.

2  MANUAL AUTO button

Use when you lost the remote controller or remote control malfunction 
occurs.

Status

Action

Mode or operation

In operation

Press more than 3 seconds.

Stop

Stopping

Press more than 3 seconds and 

less than 10 seconds.

AUTO

Press more than 10 seconds.

(Only for servicing.*)

Forced cooling

After cleaning

Press less than 3 seconds.

Filter indicator reset

*:To stop forced cooling, press this button or Start/Stop button on the 

remote controller.

3 Front 

panel

4 Vertical 

air

fl

 ow direction louver

Each time you press “SET” button on the remote controller, the angle 
of the vertical air

fl

 ow direction louver moves as follows:

1

2

3

4

5

6 7

COOL or DRY mode

HEAT mode

1

2

3

7

6

5

*

*

4

*: Default setting in each mode.

• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay position 1 

for a while for adjustment.

• If you set the angle to position 4–7 for more than 30 minutes in 

COOL or DRY mode, they automatically return to position 3.

  In COOL or DRY mode, if the angle is set to position 4–7 for many hours, 

condensation may be formed, and the drips may wet your property.

5 Power 

diffuser

In conjunction with movement of the vertical air

fl

 ow direction louver, 

the angle of the power diffuser moves as follows:

Vertical air

fl

 ow 

direction louver

Power diffuser

3

7

6

5

4

2

1

3

2

1

4

• In SWING operation, power diffuser does not move.

6 Drain 

hose

7  Remote control signal receiver

 

CAUTION

For appropriate signal transmission between remote controller and 
the indoor unit, keep the signal receiver away from following items:

 

- Direct sunlight or other strong light

 

- Flat-panel television screen

In rooms with instantaneous 

fl

 uorescent lights, such as in-

verter type ones, the signal may not be transmitted properly. In 
such a case, consult the store that you purchased the product.

8  ECONOMY indicator (green)

Lights in ECONOMY operation and in 10 °C HEAT operation.

9  TIMER indicator (orange)

Lights in TIMER operation, and blinks slowly when the timer setting 
error is detected.
As for the timer setting error, refer to “Auto-restart function” on page 5.

10  OPERATION indicator (green)

Lights in normal operation, and blinks slowly in automatic defrosting 
operation.

6

1

3

4

5

8

9

10

11

13

2

12

7

11  Horizontal air

fl

 ow direction louvers

 

CAUTION

Before you adjust the horizontal air

fl

 ow direction, make sure that 

the vertical air

fl

 ow direction louver has been stopped completely.

Adjust two knobs by hand.

See page 6

12  Air 

fi

 lter

See page 7

13  Air cleaning 

fi

 lters

Purify or deodorize the air, and provide fresh air

fl

 ow.

 Indoor unit accessories

Remote 
controller

Batteries

Air cleaning 

fi

 lters

Filter holders

Remote controller 
holder

Tapping screws

 

WARNING

Take care to prevent infants and young children from acciden-
tally swallowing the batteries.

Remote controller holder installation

3

2

1

Screws

Insert

Slide up

Indoor Unit Overview and Operations

9333003047-04_OM.indb   2

9333003047-04_OM.indb   2

12/19/2017   5:10:39 PM

12/19/2017   5:10:39 PM

Содержание ASG7MI-LM

Страница 1: ...ling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate this product with air filters installed Ensure that any electronic equipment is at least 1 m 40 in away from either the indoor unit or outdoor unit Disconnect all the power supply when...

Страница 2: ...Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in ver...

Страница 3: ... control range noticeably shortens replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 Start Stop button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minut...

Страница 4: ...topping In FAN mode either of swing direction 1 3 or 4 7 is performed in accordance with the vertical airflow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control...

Страница 5: ...the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the heating operation the outdoor unit will stop...

Страница 6: ...ft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise C...

Страница 7: ... have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts thoroughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In...

Страница 8: ...rates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation is performed in AUTO mode the fan rotates at very low speed When multiple units are operated in follo...