General AOH12RSJC Скачать руководство пользователя страница 3

Все каталоги и инструкции здесь:

 http

:

//splitoff.ru/tehn-doc.html

En-2

FEATURES AND FUNCTIONS

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched au-
tomatically to maintain the set temperature, and the tem-
perature is kept constant at all times.

SLEEP TIMER

When  the  SLEEP  button  is  pressed  during  Heating  mode,
the air conditioner’s thermostat setting is gradually lowered
during  the  period  of  operation;  during  cooling  mode,  the
thermostat setting is gradually raised during the period of
operation. When the set time is reached, the unit automati-
cally turns off.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient con-
trol of air conditioner operation.

SWING OPERATION

The Air Flow Direction Louvers swings automatically up and
down  so  that  the  air  speeds  to  every  nook  and  corner  of
your room.

REMOVABLE INTAKE GRILLE

The indoor unit’s Intake Grille can be removed for easy clean-
ing and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When  the  FAN  CONTROL  button  is  used  to  select  QUIET,
the unit begins super-quiet operation; the indoor unit’s air-
flow is reduced to produce quieter operation.

AIR CLEANING FILTER (Optional)

The  optional  Air  Cleaning  Filter  (Model  APS-03B)  uses  an
electrostatic  principle  to  clean  the  air  of  fine  particulate
matter such as tobacco smoke and plant pollen.

9312175024-01_en.pm6.5

2004.2.5, 8:58 AM

2

Содержание AOH12RSJC

Страница 1: ...här nedan Os seguintes produtos referenciados na lista abaixo estão em conformidade com as normas Соответствуя указанным стандартам данные изделия отвечают требованиям ниже перечисленных директив a EC Council Directive 73 23 EEC b EC Council Directive 89 336 EEC Place of Issue F R Germany Title of Authority General Manager Date of Issue 1 NOVEMBER 2002 Declaration Reference FUJITSU GENERAL EURO Gm...

Страница 2: ...NIDAD EXTERIOR Altura anchura profundidad 535 650 250 mm Peso 26 kg NETO PRESSIONE MASSIMA ASPIRAZIONE 800 kPa EMISSIONE 2 700 kPa REFRIGERANTE R22 650 g DIMENSIONI E PESO APPARECCHIO INTERNO Altezza Larghezza Profondità 257 808 187 mm Peso 8 0 kg netti APPARECCHIO ESTERNO Altezza Larghezza Profondità 535 650 250 mm Peso 26 kg netti ΜΕΓΙΣΤΗ ΠΙΕΣΗ ΑΝΑΡΡΟΦΗΣΗ 800 kPa ΕΚΤΟΝΩΣΗ 2 700 kPa ΨΥΚΤΙΚΟ R22 6...

Страница 3: ...llows convenient con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing clea...

Страница 4: ...EL TIMER button R FAN CONTROL button S START STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switch to test...

Страница 5: ... If the remote control unit s operating range becomes appre ciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid o...

Страница 6: ...al room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issue...

Страница 7: ...ditioner will operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defr...

Страница 8: ...rder Set the time while the ON TIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ON Timer mark will be shown on the remote control unit s dis play The Indoor Unit Timer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANC...

Страница 9: ...ically modifies the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapse...

Страница 10: ... Direction Louvers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 T Each time the button is pressed the air dir...

Страница 11: ...west downward range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control pan...

Страница 12: ...erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is all...

Страница 13: ...air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor u...

Страница 14: ...the OPERATION indicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with...

Страница 15: ...may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods un...

Отзывы: