millivolt value respectively. If differences among these values are obvious, please adjust
weighing mechanism.
3. Linearity Test for Load Cell
Load same weight for several times, and record displayed value every time. If one or
two values are obviously much larger or smaller than any others, it means that the linearity
of load cell is bad.
*NOTE: You must use
to zero display data before weight is loaded
for each time.
3.4 Calibration with Weights
During calibration with weight
,
please record the zero millivolt value, gain millivolt
value and the loaded weight value in the blank table below. If it is not convenient to load a
weight to calibrate, these values can be used for calibration without weights.
Zero millivolt
value(mV)
Gain millivolt
value(mV)
Loaded Weight
Date
Remarks
1
2
3
4
5
3.5 Calibration without Weights
When it is not convenient to load a weight to calibrate, calibration can be done without
weights using recorded data in the table in section 3.4. However, this method is just used for
some emergencies, it will make calibration result incorrect if load cells, or indicator has
been replaced.
3.5.1 Calibration without Weights for Tuxon-A
Содержание Tuxon-A
Страница 1: ...Tuxon A User s Manual Ver 1 2012 10...
Страница 4: ......
Страница 7: ...3 1 5 Technical Specifications...
Страница 8: ...4 1 6 Dimensions of Indicator...
Страница 9: ...5 2 Installation and Wiring 2 1 How to Install Indicator...
Страница 13: ...9 3 2 Flow Chart of Calibration 3 2 1 Flow Chart of Calibration for Tuxon A...
Страница 14: ...10...
Страница 20: ...16 4 2 Parameter Setting Method 4 2 1 Data Input Method 4 2 2 Option Selecting Method...