GM8802C-D Weighing Transmitter
GM8802C-D110101 89
1
character
2
characters
2
characters
4
characters
4
characters
2
characters
2
characters
Received data sequence is correct:
Query command
:
3A 30 31 30 33 30 30 30 37 30 30 30 32 46 33 0D 0A
Received data sequence is correct
:
3A 30 31 30 33 30 34 30 30 30 30 30 30 30 35 46 33 0D 0A
The data for Register
0007
and Register
0008
:
:
0
(
Hex
:
0000H
)、
5
(
Hex
:
0005H
)
05 Force single coil
Query:
Query information assigns the address of the coil that need to be forced
;
A constant in
query data district the
ON/OFF
status for the requested coil:
FF00
value for
ON
status,
0000H
value for
OFF
status. Other value is ineffective to the coils.
Response:
The coil being force status returns to normal response.
Start
Transmitter
address
Function
code
Counting
byte
Register
0007
Register
0008
LRC
Check
End
1
character
2
characters
2
characters
4
characters
4
characters
2
characters
2
characters
2
characters