Thank you very much for choosing a General International product!

For future reference, please complete the owner’s record below:
Serial Number/Lot Date Code: 
Purchase Date: 
Save the receipt, warranty, and this manual. It is important that you read the entire manual to become 

familiar with this product before you begin using it.
This air compressor is designed for certain applications only. General International is not responsible for 

issues arising from modification or improper use of this product such as an application for which it was not 

designed. We strongly recommend that this product not be modified and/or used for any application other 

than that for which it was designed.

THANK YOU

for choosing this General International machine. This tool has been carefully tested and inspected before 

shipment and if properly used and maintained, will provide you with years of reliable service. To ensure 

optimum performance and trouble-free operation, and to get the most from your investment, please take the 

time to read this manual before assembling, installing and operating the unit.
The manual’s purpose is to familiarize you with the safe operation, basic function, and features of this 

tool as well as the set-up, maintenance and identification of its parts and components. This manual is not 

intended as a substitute for formal woodworking instruction, nor to offer the user instruction in the craft of 

woodworking. If you are not sure about the safety of performing a certain operation or procedure, do not 

proceed until you can confirm, from knowledgeable and qualified sources, that it is safe to do so.

Once you’ve read through these instructions, keep this manual handy for future reference.

GENERAL

®

 INTERNATIONAL WARRANTY

All component parts of General

®

 International products are carefully inspected during all stages of production 

and each unit is thoroughly inspected upon completion of assembly.

2-Year Limited Warranty

All products are warranted for a period of 2 years (24 months) from the date of purchase. General

®

 

International agrees to repair or replace any part or component which upon examination, proves to be 

defective in either workmanship or material to the original purchaser during this 2-year warranty period, 

subject to the “conditions and exceptions” as listed below. Repairs made without the written consent of 

General International will void the warranty.

Disclaimer

The information and specifications in this manual pertain to the unit as it was supplied from the factory at 

the time of printing. Because we are committed to making constant improvements, General International 

reserves the right to make changes to components, parts or features of this unit as deemed necessary, 

without prior notice and without obligation to install any such changes on previously delivered units. 

Reasonable care is taken at the factory to ensure that the specifications and information in this manual 

corresponds with that of the unit with which it was supplied. However, special orders and “after factory” 

modifications may render some or all information in this manual inapplicable to your machine. Further, as 

several generations of this tool model and several versions of this manual may be in circulation, if you own 

an earlier or later version of this unit, this manual may not depict your machine exactly. If you have any 

doubts or questions contact your retailer or our support line with the model and serial number of your unit for 

clarification.

To file a Claim

To file a claim under our Standard 2-year Limited Warranty, all defective parts, components or machinery 

must be returned freight or postage prepaid to General

®

 International, or to a nearby distributor, repair center 

or other location designated by General

®

 International. For further details contact our service department: 

USA toll-free (844) 877-5234 or (419) 877-5234 or through our websites: www.gipowerproducts.com and 

www.general.ca. Along with the return of the product being claimed for warranty, a copy of the original proof 

of purchase and a “letter of claim” must be included (a warranty claim form can also be used and can be 

obtained, upon request,  from General

®

 International or an authorized distributor) clearly stating the model 

and serial number of the unit (if applicable) and including an explanation of the complaint or presumed defect 

in material or workmanship.

Conditions and exceptions

This coverage is extended to the original purchaser only. Prior warranty registration is not required but 

documented proof of purchase, i.e. a copy of original sales invoice or receipt showing the date and location 

of the purchase as well as the purchase price paid, must be provided at the time of claim.
Warranty does not include failures, breakage or defects deemed after inspection by General

®

 International 

to have been directly or indirectly caused by or resulting from; improper use, or lack of or improper 

maintenance, misuse or abuse, negligence, accidents, damage in handling or transport, or normal wear and 

tear of any generally considered consumable parts or components.
Repairs made without the written consent of General

®

 International will void all warranty.

Содержание AC1220

Страница 1: ... Owner s Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Model AC1220 READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ... unit as it was supplied from the factory at the time of printing Because we are committed to making constant improvements General International reserves the right to make changes to components parts or features of this unit as deemed necessary without prior notice and without obligation to install any such changes on previously delivered units Reasonable care is taken at the factory to ensure tha...

Страница 3: ...ounding 8 Grounded Tools Tools with 3 Prong Plugs 8 Extension Cords 8 Main Parts of Air Compressor 11 Getting Started 12 Assembly 12 Pre Operation 12 Before operating your air compressor 12 General Overview 12 Installation and Location 12 Before Each Use 13 Accessories 13 Accessories for this unit are sold separately 13 Operating Instructions 13 Drain Valve 14 Pressure Switch 14 Adjusting the air ...

Страница 4: ...m Branch Circuit Requirement 15 Amps Fuse Type Time Delay Air Tank Capacity Vertical 20 gallons 75 7 liters Motor Speed 3 400 RPM Maximum Operating Air Pressure 125 psi Maximum Tank Air Pressure 150 psi CFM 40 psi 4 18 CFM 90 psi 2 31 Fill Time 0 psi To 40 psi 1 Minute 47 Seconds Fill Time 0 psi To 90 psi 6 Minutes 47 Seconds Fill Time 0 psi To 125 psi 10 Minutes 35 Seconds Recovery Time 90 125 ps...

Страница 5: ...t in injury Using the product in confined work areas may put you dangerously close to cutting tools and rotating parts Do not use the product where there is a risk of causing a fire or an explosion e g in the presence of flammable liquids gases or dust The product can create sparks which may ignite the flammable liquids gases or dust Do not allow the product to come into contact with an electrical...

Страница 6: ...or animals CAUTION Air Compressor Use And Care Do not force the air compressor Products are safer and do a better job when used in the manner for which they are designed Plan your work and use the correct product for the job Check for damaged parts before each use Carefully check that the product will operate properly and perform its intended function Replace damaged or worn parts immediately Neve...

Страница 7: ...ngs accordingly DO NOT exceed manufacturer s rated safe operating pressures for these items Make sure all hose connections are adequately secured to prevent tools or hose ends from being accidentally disconnected Remove adjusting keys or wrenches before turning the tool on A wrench or key that is left attached to a moving part of the tool may result in personal injury Keep work area clean and well...

Страница 8: ...reak down grounding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See Figure 1 The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to an electrically live...

Страница 9: ...g Select a properly grounded extension cord which will mate directly with the power source receptacle and the air compressor power cord without the use of adapters Make certain that the extension cord is properly wired and in good electrical condition When using more than one extension cord to make up the total length make sure each cord contains at least the minimum wire size required If you are ...

Страница 10: ...r pump to the tank K Handle For transportability L Handle Bolts Allows attachment of handle removal for storage M Wheels Allow easy portability N Rubber Foot Provides anti vibration and stability O Air Tank 20 gallons 75 7 liters Further Functional Information TANK SAFETY VALVE The safety valve automatically relieves pressure from the air tank in the event of excessive pressure build up Safety Val...

Страница 11: ...11 AC1220 man v 190926 Air Compressor 11 MAIN PARTS OF AIR COMPRESSOR N G A M M K L L B C D E F H I O fig 2 J ...

Страница 12: ...on the CFM draw of the tools being operated your new air compressor can be used for operating paint sprayers air tools grease guns airbrushes caulking guns abrasive blasters tire plastic toy inflation spraying weed killer and insecticides etc Proper adjustment of the air pressure regulator is necessary for all of these operations Refer to the air pressure specifications provided with the tool you ...

Страница 13: ...n air hose Your air compressor is supplied with a 1 4 push connect air coupler fig 3 With a factory installed air coupler your compressor is ready to accept air hoses equipped with 1 4 male air connectors fig 4 Use only air hoses rated for use with 150 psi air pressure or higher To install any air hose equipped with a 1 4 male connector fig 4 1 Simply push the connector or plug into the fitting an...

Страница 14: ... sure it is within the safety standards required to perform the task If using a pneumatic tool the manufacturer should have recommendations in the manual for that particular tool on operating psi settings Drain Valve Make sure the tank drainage valve fig 5 is closed and not in the open position Pressure Switch 1 Check that the red pressure switch button is pushed down to the OFF position fig 6 2 E...

Страница 15: ...er follow these tips 1 Try to keep the air compressor stored in temperatures above 32 F 0 C 2 Open the air tank drain valve and release all air pressure from the air tank before attempting to start in cold weather After air is released from air tank close drain valve 3 Pull the ring on the safety valve before each use to make sure the valve is functional 4 Plug the air compressor directly into a 1...

Страница 16: ...utomatic reset thermal overload protector which will shut off the motor if it becomes overheated If the thermal overload protector is actuated the motor must be allowed to cool down before start up is possible NOTE To reset the motor overload turn the power switch to the OFF position and unplug the unit from the power outlet Allow 10 minutes minimum for motor overload cut out to cool and reset Uni...

Страница 17: ...lve 3 Check valve by pulling on ring If condition persists replace valve Safety valve releases Defective pressure switch Replace pressure switch Pressure in tank falls 1 Air leaks at joints 1 Allow the compressor to build pres sure in the tank to the max pressure if possible Spray or brush soapy water on all air connections and look for bub bles Tighten leaky connections Do not over tighten 2 If t...

Страница 18: ...lve dam aged Stop the compressor and contact cus tomer support Compressor doesn t provide as much air as when new and or cuts off after a much shorter time period 1 Tank has reduced capacity due to water retention 2 Pressure switch is out of adjust ment 1 Open drain valve to release water 2 Contact customer support Pump unit does not stop when the tank reaches maxi mum working pressure Defective o...

Страница 19: ...19 AC1220 man v 190926 Air Compressor This page intentionally left blank ...

Страница 20: ...20 General International ...