General Equipment RIP-R-STRIPPER FCS10GEN2 Скачать руководство пользователя страница 7

FCS10GEN2 RIP-R-STRIPPER

®

 FLOOR COVERING STRIPPER 

FORM GOM03042001US, VERSION 1.2 

 

 

 

 

 

       

English-EN

 

 

6

 

 

 

OPERATIONAL HAZARDS 

 

1. 

RIP-R-STRIPPER is designed to substantially enhance machine control 

and reduce operator fatigue provided accessory tool does not directly 

contact larger, protruding obstructions (anchor bolts, pipes, nail heads, 

columns, openings, large cracks, utility outlets, material variances, etc., or 

any objects protruding from work surface).  Such contact can result in 

rapid and jerky movement of machine and/or loss of machine control.  

 

2. 

The floor covering material removal process can produce sparks, dusts 

and other foreign particle contamination that can result in fire and/or 

explosion depending on existing jobsite conditions.  

 

3. 

Many covering materials, adhesives or mastics can contain asbestos and 

other chemicals that are known to cause physical harm and/or affect the 

environment.  

 

4. 

Excessive water, and/or other conductive materials on work surface can 

result in electrocution of operator and/or other personnel.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preventive Measures: 

 

Operator must maintain physical and mental alertness. Be prepared for 

unexpected blade contact with protruding anchor bolts, etc. and be 

capable to sense level of machine control they have.  

 

 

DO NOT operate RIP-R-STRIPPER on jobsite where kickback forces can 

allow body parts to come in direct contact with vertical wall, foundation or 

other support type structures. Maintain a safe and reasonable distance 

from these structures.  

 

Maintain proper operating stance for better control of machine plus, 

reducing operator error and fatigue. Refer to PROPER OPERATOR 

STANCE in OPERATING INSTRUCTIONS section of this manual for 

more information. 

 

 

Remove water and/or conductive materials by industry-approved and/or 

accepted practice BEFORE removing floor covering. Determine RIP-R-

STRIPPER is properly grounded and extension cords are free of cuts, 

abrasions and/or exposed cable strands. 

 

 

Dust and other particle contamination can be controlled by use of 

appropriate industrial-type dust collection system to remove/control dust 

and other particle contamination from work surface. 

  CAUTION

         

 

 

Exercise extreme caution when operating RIP-R-STRIPPER 

in vicinity of anchor bolts, pipes, columns, openings, large 

cracks, utility outlets or any object protruding from work 

surface.  

 

Contact with such objects can lead to loss of machine control, 

resulting in property damage and/or personal injury. 

 

  WARNING

      

 

 

Exercise extreme caution when operating RIP-R-

STRIPPER on above ground level floors to prevent loss of 

control allowing machine and/or operator to fall down to 

lower levels. 

 

When moving backwards during floor covering removal 

process, be aware of potential drop-offs and obstructions 

on job site. 

 

  WARNING

     

 

 

Sparks produced by action of accessory cutting blade 

against work surface (e.g.- striking anchor bolts) can 

result in fire and/or explosion depending on existing 

environmental conditions. 

 

This occurrence can result in property damage and/or 

personal injury. 

 

  WARNING

      

 

 

Creation of dust and other foreign particle contamination 

from floor covering removal process can result in 

property damage and/or personal injury. 

 

For such operating conditions, always wear NIOSH/MSHA 

approved dust/mist respirator and appropriate safety 

related apparel. 

 

Consult applicable OSHA regulations for specific 

information. 

 

  WARNING

      

 

 

Always use dust collection system that meets specific job 

site requirements. 

 

Dust materials can meet Class II and Class III National 

Electric Code specifications for hazardous materials. 

 

Consideration must be given to creation of hazardous 

materials requiring specific disposal procedures. 

 

Determine dust collection system is properly designed to 

operate within these atmospheres.  

 

Consult current National Electric Code, OSHA and EPA 

regulations for specific information. 

 

  WARNING

      

 

 

Water and other conductive materials on work surface 

increases electrocution hazard potential for operator and 

other personnel. 

 

Determine RIP-R-STRIPPER is properly grounded (no 

faults), power cords are free of cuts, abrasions and/or 

exposed cable strands. 

 

Improper grounding and use of damaged power cords 

and/or GFI can result in property damage and/or personal 

injury. 

 

DO NOT expose RIP-R-STRIPPER to rain or wet operating 

conditions. 

 

Water entering machine can increase risk of electric 

shock. 

 

  WARNING

      

 

 

Always utilize water mist spray system to operate within 

specific job site requirement. 

 

Dust materials can meet Class II or Class III National 

Electric Code specifications for hazardous materials. 

 

Consideration must be given to creation of hazardous 

materials requiring specific disposal procedures. 

 

Determine water mist spray system is properly designed 

to operate within these atmospheres. 

 

Consult current National Electric Code, OSHA and EPA 

regulations for specific information. 

 

  WARNING

      

 

 

DO NOT operate RIP-R-STRIPPER on jobsite location 

where forces generated during floor covering removal 

process can allow body parts to come in direct contact 

with vertical wall, foundation or other support type 

structures in close proximity.  

 

Such occurrence can result in property damage and/or 

personal injury. Always maintain a safe and reasonable 

distance from these type structures.  

 

Содержание RIP-R-STRIPPER FCS10GEN2

Страница 1: ...ation or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Cus...

Страница 2: ...10 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution to many types of...

Страница 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Страница 4: ...RIP R STRIPPER operation by owner s and or operator s Program will include but is not limited to instructional operation requirements applicable OSHA requirements local laws and regulations job site...

Страница 5: ...e by BACK CARE PROPER LIFTING PROCEDURES Operators will be required to lift the RIP R STRIPPER as demanded by specific job applications When lifting one person is required Utilize proper lifting techn...

Страница 6: ...al RIP R STRIPPER use is on level surfaces Avoid other surface conditions which can be dangerous Special care must be exercised on slippery and or difficult uneven surfaces Watch for cracks high spots...

Страница 7: ...level floors to prevent loss of control allowing machine and or operator to fall down to lower levels When moving backwards during floor covering removal process be aware of potential drop offs and ob...

Страница 8: ...irable damage to electric motor and related controls 7 STANDARD PRODUCT ACCESSORIES Refer to FIGURE 3 for overview description of standard components included in machine Included in shipment for FSC10...

Страница 9: ...s in OFF position and unit is not connected to power source 6 Connect power head power cord to power cord located at switch end of operator handle assembly Twist to lock to prevent separation FIGURE 6...

Страница 10: ...ound cap screw shanks located toward left right sides of unit NOTE Blades are provided with a protective finish When not in use protect and store blades appropriately to prevent rust damage 7 Tighten...

Страница 11: ...vel direction is important for floor removal performance and preventing damage to flooring substrates NOTE On cement surfaces blade beveled cutting edge is positioned facing up FIGURE 11 FIGURE 11 NOT...

Страница 12: ...lower shear force is required to remove and increases floor covering removal rates The accepted procedure is to decrease effective blade width plus determine optimal blade angle relative to work surfa...

Страница 13: ...t potential fault WARNING If operating RIP R STRIPPER in outside environment use only extension cords marked W A or W Such cords are rated for outside usage and reduce risk of electric shock DANGER DO...

Страница 14: ...to determine proper material removal depths and extent of work completed Lack of proper dust collection system and or broom use can increase problem IMPORTANT Properly dispose of all accumulated floo...

Страница 15: ...ps as needed IMPORTANT Electric motor is an enclosed fan cooled design Keep power head housing air vents clear of material accumulations for proper air flow cooling IMPORTANT DO NOT use thinner benzen...

Страница 16: ...dry film lubricant DO NOT use other type lubricants that can attract foreign materials reducing service life 2 Exciter flywheel support bearing is sealed and will not normally require lubrication dur...

Страница 17: ...for correct voltage and amperage ACCELERATED EXCITER FLYWHEEL BEARING WEAR AND OR FAILURE Possible Cause Correction Misaligned and or improperly tensioned transmission mount and exciter plate Check e...

Страница 18: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 18...

Страница 20: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 19...

Страница 21: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 20...

Страница 22: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 21...

Страница 23: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 22...

Страница 24: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 23...

Страница 25: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 24...

Страница 26: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 25...

Страница 27: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 26...

Отзывы: