2. 

To lift and carry the RIP-R-STRIPPER grab operator handle shaft, using 

one hand, just above where handle attaches to main frame portion of unit.  

FIGURE 1 

                

                 FIGURE 1 

 

3. 

As unit is lifted, using proper lifting procedures, use other hand to place 

down-pressure on opposite end of operator handle.  This will balance unit 

on first hand in STEP 2. Operator handle will be fairly level to ground with 

blade attachment clamp pointing upward.

 

FIGURE 2 

 

                FIGURE 2 

 

4. 

To reduce storage area and minimize damage, transport                     

RIP-R-STRIPPER in normal upright position with operator handle 

assembly removed from main frame. Refer to STEP 7 of INSTALLING & 

REMOVING OPERATOR HANDLE of MACHINE SET-UP section in this 

manual to remove handle assembly. 

 

a) 

DO NOT allow operator handle and main frame to make direct 

contact with each other while transporting. Provide proper 

protection between RIP-R-STRIPPER components and 

vehicle.  

 

b) 

DO NOT drop unit directly against exciter plate. Provide 

support block under main frame to prevent direct contact 

and/or damage to exciter plate and related components.  

 

5. 

All equipment must be secured in/on vehicles with suitable strapping or 

tie downs. Personnel should not be transported in same compartment as 

equipment and supplies. Consult applicable OSHA regulations for specific 

information. 

 

DETERMINATION OF POTENTIAL SUBSURFACE HAZARDS IN 

PROPOSED FLOORING REMOVAL LOCATION(S) 

 

RIP-R-STRIPPER operator handle grips are constructed of non-metallic 

composite material and do not guarantee operators will be properly insulated 

from contact with charged electrical cables. RIP-R-STRIPPER and related 

accessories are not classified as insulated.  

RIP-R-STRIPPER is not sealed or insulated.  DO NOT operate                     

RIP-R- STRIPPER in an explosive atmosphere or near combustible materials.  

Refer to OSHA rules and regulations. 

 

DETERMINATION OF POTENTIAL ABOVE SURFACE HAZARDS IN 

PROPOSED FLOORING REMOVAL LOCATION(S)

 

 

 

Normal RIP-R-STRIPPER use is on level surfaces. Avoid other surface 

conditions which can be dangerous. Special care must be exercised on 

slippery, and/or difficult/uneven surfaces. Watch for cracks, high spots/other 

surface irregularities or drop offs to lower floor levels. Operate only when/where 

visibility and light are adequate for job at hand. Remove any trip/fall hazard 

BEFORE operating RIP-R-STRIPPER. Keep proper footing and balance at all 

times.  

 

 

 

 

 

 

 

  DANGER      

 

 

DO NOT attempt carrying/lifting/lowering RIP-R-STRIPPER 

and/or doing so into/from transportation vehicle if person 

is not in proper physical/mental condition or unfamiliar in 

proper lifting procedures. 

 

Such actions can result in property damage and/or 

personal injury.  

 

  WARNING        

 

 

Disconnect extension cord from RIP-R-STRIPPER when 

traversing up and down stairs. 

 

Store RIP-R-STRIPPER power cord on operator handle 

retention device when traversing up and down stairs. 

 

Improperly stored/connected cord can entrap and/or 

entangle personnel. 

 

Such occurrence can result in property damage and/or 

personal injury. 

 

  DANGER      

 

 

Always assume floor covering removal location contains 

buried underground obstructions. 

 

BEFORE attempting to operate RIP-R-STRIPPER in 

proposed location(s), call 811 and/or visit 

www.Call811.com

 .  

 

Contact all appropriate agencies to determine exact 

location(s) of all buried pipelines, powerlines and material 

debris.  

 

Many utilities and other agencies will perform these tasks 

at minimal charge or at no cost. Have all subsurface 

hazards marked for easy recognition.  

 

Direct contact with these and other subsurface hazards 

can result in property damage and/or personal injury 

through such things as electrocution and/or explosion. 

 

  WARNING      

 

BEFORE attempting to operate RIP-R-STRIPPER, identify/mark all 

potential subsurface hazards in proposed floor covering removal 

location(s). Potential subsurface hazards may include, but may not 

be limited to the following: 

 

1. 

Buried debris, rotted timbers or wood planking. 

2. 

Buried pressurized pipelines (e.g. natural gas, propane, 

etc.) 

3. 

Buried electrical cables. 

 

  CAUTION 

 

An improperly secured RIP-R-STRIPPER and related 

accessories can fall from moving vehicle and result in property 

damage and/or personal injury. 

 

Содержание RIP-R-STRIPPER FCS10GEN2

Страница 1: ...ation or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Cus...

Страница 2: ...10 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution to many types of...

Страница 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Страница 4: ...RIP R STRIPPER operation by owner s and or operator s Program will include but is not limited to instructional operation requirements applicable OSHA requirements local laws and regulations job site...

Страница 5: ...e by BACK CARE PROPER LIFTING PROCEDURES Operators will be required to lift the RIP R STRIPPER as demanded by specific job applications When lifting one person is required Utilize proper lifting techn...

Страница 6: ...al RIP R STRIPPER use is on level surfaces Avoid other surface conditions which can be dangerous Special care must be exercised on slippery and or difficult uneven surfaces Watch for cracks high spots...

Страница 7: ...level floors to prevent loss of control allowing machine and or operator to fall down to lower levels When moving backwards during floor covering removal process be aware of potential drop offs and ob...

Страница 8: ...irable damage to electric motor and related controls 7 STANDARD PRODUCT ACCESSORIES Refer to FIGURE 3 for overview description of standard components included in machine Included in shipment for FSC10...

Страница 9: ...s in OFF position and unit is not connected to power source 6 Connect power head power cord to power cord located at switch end of operator handle assembly Twist to lock to prevent separation FIGURE 6...

Страница 10: ...ound cap screw shanks located toward left right sides of unit NOTE Blades are provided with a protective finish When not in use protect and store blades appropriately to prevent rust damage 7 Tighten...

Страница 11: ...vel direction is important for floor removal performance and preventing damage to flooring substrates NOTE On cement surfaces blade beveled cutting edge is positioned facing up FIGURE 11 FIGURE 11 NOT...

Страница 12: ...lower shear force is required to remove and increases floor covering removal rates The accepted procedure is to decrease effective blade width plus determine optimal blade angle relative to work surfa...

Страница 13: ...t potential fault WARNING If operating RIP R STRIPPER in outside environment use only extension cords marked W A or W Such cords are rated for outside usage and reduce risk of electric shock DANGER DO...

Страница 14: ...to determine proper material removal depths and extent of work completed Lack of proper dust collection system and or broom use can increase problem IMPORTANT Properly dispose of all accumulated floo...

Страница 15: ...ps as needed IMPORTANT Electric motor is an enclosed fan cooled design Keep power head housing air vents clear of material accumulations for proper air flow cooling IMPORTANT DO NOT use thinner benzen...

Страница 16: ...dry film lubricant DO NOT use other type lubricants that can attract foreign materials reducing service life 2 Exciter flywheel support bearing is sealed and will not normally require lubrication dur...

Страница 17: ...for correct voltage and amperage ACCELERATED EXCITER FLYWHEEL BEARING WEAR AND OR FAILURE Possible Cause Correction Misaligned and or improperly tensioned transmission mount and exciter plate Check e...

Страница 18: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 18...

Страница 20: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 19...

Страница 21: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 20...

Страница 22: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 21...

Страница 23: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 22...

Страница 24: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 23...

Страница 25: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 24...

Страница 26: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 25...

Страница 27: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 26...

Отзывы: