General Equipment RIP-R-STRIPPER FCS10GEN2 Скачать руководство пользователя страница 13

FCS10GEN2 RIP-R-STRIPPER

®

 FLOOR COVERING STRIPPER 

FORM GOM03042001US, VERSION 1.2 

 

 

 

 

 

       

English-EN

 

 

12

 

 

 

            FIGURE 17 

 

3. 

Install operator handle assembly to main frame per STEPS 1 thru 6 in 

INSTALLING & REMOVING OPERATOR HANDLE section within 

MACHINE SET-UP section of this manual. 

 

4. 

Install accessory blade per procedures in INSTALLING & REMOVING 

ACCESSORY BLADES in MACHINE SET-UP section of this manual. 

 

5. 

Lock power head ON/OFF switch into ON position by placing index finger 

on bottom side, front portion, of switch then rock up and toward bottom of 

operator handle until it locks in place. FIGURE 18 

 

               FIGURE 18 

NOTE:

 To release power head switch to OFF position, simply press upward on 

back portion of switch and release.  Front portion of switch will unlock and 

become fully exposed. 

 

6. 

Connect extension cord to main power cord of RIP-R-STRIPPER. 

FIGURE 19 

                                  

             FIGURE 19 

   

 

 

 

 

7. 

Connect additional extension cord to remaining end of first extension cord 

(if applicable). 

 

IMPORTANT:

 If additional extension cords are required, each cord must be of 

proper structural integrity and size (AWG) to meet applicable National Electric 

Code and OSHA requirements.  An additional extension cord with integral GFI 

can be used in conjunction with RIP-R-STRIPPER which also has an integral 

GFI. 

  

 

  WARNING 

 

For maximum protection against a fault, if used, always 

configure GFI to be plugged into power source 

receptacle.   

 

Configurations with GFI placed between RIP-R-STRIPPER 

and power source will not provide maximum protection 

against potential fault. 

 

 

  WARNING

      

 

 

If operating RIP-R-STRIPPER in outside environment, use 

only extension cords marked “W-A” or “W”.  

 

Such cords are rated for outside usage and reduce risk of 

electric shock. 

 

  DANGER

      

 

 

DO NOT operate RIP-R-STRIPPER without extension 

cords/GFI in proper operating condition.  The GFI is 

intended as a safety device in event power source has a 

fault. 

 

Always assume electrical wiring on every jobsite can 

contain a fault. 

 

A fault can generate a dangerous operating configuration 

that can result in property damage and/or personal injury. 

  WARNING 

 

Unexpected machine start-up can result in property 

damage and/or personal injury. 

  WARNING

      

 

 

DO NOT modify or replace any extension cord component 

without utilizing a factory approved component only. 

  WARNING

      

 

 

All electrical wiring including extension cord gauge and/or 

length must be installed and/or approved in accordance 

with local electrical codes and practices.   

 

An improper wiring installation can result in property 

damage and/or personal injury. 

 

 

  WARNING

      

 

 

Keep power and extension cords free and clear of 

machine and blade. 

 

In event extension cord becomes entangled about RIP-R-

STRIPPER and/or operator turn machine OFF 

immediately. 

 

Determine extension cords/GFI are in proper condition to 

continue operation. 

 

In event of damage, replace with factory approved 

component only and/or products meeting applicable 

National Electric Code and OSHA requirements. 

 

  WARNING

      

 

 

DO NOT abuse the power cord. Never use power cord to 

move RIP-R-STRIPPER or pull plug from receptacle. 

Damage to cord can result.  

 

Keep cord away from heat, oil, sharp edges (including 

accessory tool) or moving parts.  

 

A damaged cord increases the risk of an electric shock. 

 

Содержание RIP-R-STRIPPER FCS10GEN2

Страница 1: ...ation or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Cus...

Страница 2: ...10 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution to many types of...

Страница 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Страница 4: ...RIP R STRIPPER operation by owner s and or operator s Program will include but is not limited to instructional operation requirements applicable OSHA requirements local laws and regulations job site...

Страница 5: ...e by BACK CARE PROPER LIFTING PROCEDURES Operators will be required to lift the RIP R STRIPPER as demanded by specific job applications When lifting one person is required Utilize proper lifting techn...

Страница 6: ...al RIP R STRIPPER use is on level surfaces Avoid other surface conditions which can be dangerous Special care must be exercised on slippery and or difficult uneven surfaces Watch for cracks high spots...

Страница 7: ...level floors to prevent loss of control allowing machine and or operator to fall down to lower levels When moving backwards during floor covering removal process be aware of potential drop offs and ob...

Страница 8: ...irable damage to electric motor and related controls 7 STANDARD PRODUCT ACCESSORIES Refer to FIGURE 3 for overview description of standard components included in machine Included in shipment for FSC10...

Страница 9: ...s in OFF position and unit is not connected to power source 6 Connect power head power cord to power cord located at switch end of operator handle assembly Twist to lock to prevent separation FIGURE 6...

Страница 10: ...ound cap screw shanks located toward left right sides of unit NOTE Blades are provided with a protective finish When not in use protect and store blades appropriately to prevent rust damage 7 Tighten...

Страница 11: ...vel direction is important for floor removal performance and preventing damage to flooring substrates NOTE On cement surfaces blade beveled cutting edge is positioned facing up FIGURE 11 FIGURE 11 NOT...

Страница 12: ...lower shear force is required to remove and increases floor covering removal rates The accepted procedure is to decrease effective blade width plus determine optimal blade angle relative to work surfa...

Страница 13: ...t potential fault WARNING If operating RIP R STRIPPER in outside environment use only extension cords marked W A or W Such cords are rated for outside usage and reduce risk of electric shock DANGER DO...

Страница 14: ...to determine proper material removal depths and extent of work completed Lack of proper dust collection system and or broom use can increase problem IMPORTANT Properly dispose of all accumulated floo...

Страница 15: ...ps as needed IMPORTANT Electric motor is an enclosed fan cooled design Keep power head housing air vents clear of material accumulations for proper air flow cooling IMPORTANT DO NOT use thinner benzen...

Страница 16: ...dry film lubricant DO NOT use other type lubricants that can attract foreign materials reducing service life 2 Exciter flywheel support bearing is sealed and will not normally require lubrication dur...

Страница 17: ...for correct voltage and amperage ACCELERATED EXCITER FLYWHEEL BEARING WEAR AND OR FAILURE Possible Cause Correction Misaligned and or improperly tensioned transmission mount and exciter plate Check e...

Страница 18: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 18...

Страница 20: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 19...

Страница 21: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 20...

Страница 22: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 21...

Страница 23: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 22...

Страница 24: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 23...

Страница 25: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 24...

Страница 26: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 25...

Страница 27: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 26...

Отзывы: