General Equipment EP8HL Скачать руководство пользователя страница 30

EP8HL HAZARDOUS BLOWER
FORM GOM7069501, VERSION 1.2

28

FIGURE 10

6) Continuous atmospheric testing with the appropriate
equipment  is  recommended.  Contact  the  nearest
OSHA office for more specific and current information
regarding  confined  space  procedures  in  hazardous
type  locations,  policies  and  requirements.  Such
information is regularly subject to change and revision.

THE FINAL WORKING PROCEDURE FOR ANY JOB
APPLICATION  INVOLVING  THE  USE  OF  THE
BLOWER  MUST  BE  INDIVIDUALLY  DETERMINED
AFTER  CAREFUL  ANALYSIS  OF  ALL  FACTORS
AND/OR  CONDITIONS  PRESENT.  THE  NEAREST
OSHA  OFFICE  IS  A  VALUABLE  SOURCE  FOR
APPLICABLE  INFORMATION  REGARDING  THE
SAFE OPERATION OF THE BLOWER.

STOPPING THE MODEL EP8HL BLOWER.

1)  Stopping  the  EP8HL  Blower  is  accomplished  by
pushing the ON/OFF switch to the OFF position.

Do  not  disconnect  the  cord  plug  from  the
receptacle  by  pulling  on  the  power  cord.  Such
action  can  result  in  property  damage  and/or
personal  injury.  Grasping  the  plug  and  receptacle
firmly  in  hand,  twist  the  assembly  to  disconnect
and remove the plug from the receptacle.

Service

ALWAYS  STOP  THE  MOTOR  AND  DISCONNECT
THE  POWER  SOURCE  TO  PREVENT  THE
ACCIDENTAL 

STARTING 

AND/OR 

THE

POSSIBILITY  OF  RECEIVING  AN  ELECTRICAL
SHOCK  BEFORE  WORKING  ON  THE  BLOWER.
SUCH  AN  OCCURRENCE  CAN  RESULT  IN
PROPERTY DAMAGE AND/OR PERSONAL INJURY.

DO  NOT ATTEMPT ANY  SERVICE  WORK  ON  THE
BLOWER WITHIN A HAZARDOUS LOCATION TYPE
ATMOSPHERE. SERVICE WORK CAN PRODUCE A
RANDOM  SPARK  WHICH  CAN  BE  THE  IGNITION
SOURCE  OF  AN  EXPLOSION.  SUCH  AN
OCCURRENCE  CAN  RESULT  IN  PROPERTY
DAMAGE AND/OR PERSONAL INJURY.

BLOWER HOUSING MAINTENANCE.

Do not operate the Blower with a large accumulation of
dirt  and  other  debris  within  the  blower  housing
assembly.  Such  a  collection  of  foreign  material  can
affect  air  flow  delivery  performance  and  should  be
removed  periodically.  Keep  the  ground  strap  clamp
location, as indicated by the information plates on the
Blower housing, clean and free of dirt and/or corrosion.

REMOVING  THE  BLOWER  WHEEL  FROM  THE
MOTOR SHAFT.

Tools Required:

2 each, 7/16 inch wrenches
1 each, wheel puller (if required)
1 each, 5/32 inch Allen wrench

1) Remove the front housing casting with the 7/16 inch
wrenches. The exhaust screen is held in place by four
depressions  in  the  casting.  The  exhaust  screen  can
only be removed when the front casting is removed.

Содержание EP8HL

Страница 1: ...when performing any service related function When ordering replacement parts please supply the following information model number serial number and part number For customer service assistance telephon...

Страница 2: ......

Страница 3: ...able to ensure that each General product delivers the intended performance value and investment return Our personnel can readily answer your concerns or questions regarding proper applications service...

Страница 4: ...R HAZARDOUS LOCATIONS TYPE CONFINED SPACE VENTILATION STATIC ELECTRICITY CONSIDERATIONS FOR HAZARDOUS LOCATION TYPE CONFINED SPACE VENTILATION EXPLOSIVE CHEMICAL PROPERTIES CONSIDERATIONS FOR HAZARDOU...

Страница 5: ...not perceived and or anticipated by the manufacturer Such misuse and or misapplication of the Blower can lead to the possibility of serious damage injury or even death It is the responsibility of the...

Страница 6: ...re is no absolute guarantee that an operator of any given experience level physical size and or physical condition will be immune to the possibility of and or probable physical side effects of the nor...

Страница 7: ...AND DEEMED APPLICABLE TO THE SAFE AND PROPER USE AND OR OPERATION OF THE BLOWER FOR ANY SPECIFIC JOB APPLICATION 4 LOCAL LAWS REGULATIONS AND CUSTOMS RESEARCHED FOR AND OR BY THE OWNER OF THE BLOWER...

Страница 8: ...ational information video tape supplied by the manufacturer to familiarize each operator with its correct operating procedures When you are going to utilize this Blower DO IT RIGHT avoid the urge not...

Страница 9: ...wer motor securely Determine that any grounding wire and or device is in fact properly grounding the motor Failure to properly ground the motor may cause an electrical shock and or electrocution resul...

Страница 10: ...lower Determine that eyeglasses and or hearing aid devices are properly secured Use of the Blower is strenuous and causes fatigue Help prevent the cause of an accident Plan to take work breaks as requ...

Страница 11: ...ed by others can result in property damage and or personal injury 3 Follow the SERVICE instructions as outlined in the appropriate section of the Operator s Manual 4 Always properly maintain the Blowe...

Страница 12: ...ATE A RANDOM SPARK WHICH CAN BE THE IGNITION SOURCE OF AN EXPLOSION SUCH AN OCCURRENCE CAN RESULT IN PROPERTY DAMAGE AND OR PERSONAL INJURY 1 Using the wrenches remove the steel fasteners from the fra...

Страница 13: ...r loose or damaged parts Determine that all controls work freely all safety devices are operative and that information plates are readable It is essential that the Blower and all related accessories a...

Страница 14: ...ork activities within a hazardous location type atmosphere Because of the wide number of job applications for the EP8HL Blower it is impossible to develop a written Operator s Manual that is all inclu...

Страница 15: ...ard ducts intended for use in nonhazardous location type atmospheres usually orange or yellow in color can not be made to directly attach to the EP8HL Blower without major modifications to the Blower...

Страница 16: ...IS A HAZARDOUS LOCATION AND OR A PERMIT REQUIRED ACCESS A HAZARDOUS LOCATION MAY REQUIRE ADDITIONAL CONSIDERATIONS INCLUDING BUT NOT LIMITED TO PROPER ELECTRICAL WIRING DEVICES FOR THE BLOWER STATICAL...

Страница 17: ...estricted means for entry or exit 3 The space is not designed for continuous worker occupancy 29 CFR 1910 146 d The term non permit required confined work space is defined in the standard as follows a...

Страница 18: ...rtain areas Consult the current National Electric Code for specific information Typical Class I Locations Include Petroleum refining facilities Dip tanks containing flammable or combustible liquids Dr...

Страница 19: ...important consideration during the operation of an air ventilation blower in a hazardous location type atmosphere A static discharge can be the ignition source for an explosion Only proper product de...

Страница 20: ...FM 20 7 CMM TWO 90 BENDS 578 8 CFM 16 2 CMM Flow rates for the EP8HL Blower were calibrated by the Colorado Engineering Experiment Station Inc Blower components were tested per AT T standard EL2723 PL...

Страница 21: ...ELECTRICAL POWER SOURCE WILL NOT AFFORD MAXIMUM PROTECTION AGAINST A POTENTIAL FAULT National Electric Code limits flexible power cords to connections between portable utilization equipment such as th...

Страница 22: ...meeting hazardous location requirements can be fabricated in the field utilizing a 10 3 AWG CSA certified extra hard usage cord material and an Appleton ECCL2023 or equivalent receptacle certified fo...

Страница 23: ...E IN USE IN HAZARDOUS TYPE ATMOSPHERES STATICALLY CONDUCTIVE DUCTS MUST BE STORED IN DEVICES MEETING A SPARK PROOF CLASSIFICATION USE OF STORAGE DEVICES NOT MEETING A SPARK PROOF CLASSIFICATION CAN CR...

Страница 24: ...are aluminum location on the Blower housing as depicted by the information plates The procedure is similar to that utilized to secure clamps to a storage battery Determine that a proper ground connect...

Страница 25: ...antly reduce the air flow delivery performance of the Blower However field experience indicates that there can be an occasion where statically conductive ducts are required to be coupled together for...

Страница 26: ...IT IS THE RESPONSIBILITY OF THE OWNER S AND OR OPERATOR S TO DETERMINE THAT THE DUCT MATERIAL IN USE FOR THE JOB APPLICATION MEETS ALL APPLICABLE FIRE CODE AND OSHA REQUIREMENTS 6 When storing a stati...

Страница 27: ...uch as rusting or bacterial action such as fermentation can also decrease the oxygen level The oxygen level can also be decreased if it is displaced by another gas such as carbon dioxide or nitrogen T...

Страница 28: ...ype of work to be accomplished the expected hazards the types of personal safety equipment required and the types of support equipment required A permit will have a section to document atmospheric gas...

Страница 29: ...irected at an end wall FIGURE 9 and FIGURE 10 This arrangement will provide for more even air distribution and will more effectively eliminate air spaces in corners where harmful gases may accumulate...

Страница 30: ...Service ALWAYS STOP THE MOTOR AND DISCONNECT THE POWER SOURCE TO PREVENT THE ACCIDENTAL STARTING AND OR THE POSSIBILITY OF RECEIVING AN ELECTRICAL SHOCK BEFORE WORKING ON THE BLOWER SUCH AN OCCURRENC...

Страница 31: ...nstructed of aluminum Do not over torque the fasteners REPLACE ANY DAMAGED FASTENER WITH A FACTORY APPROVED REPLACEMENT PART ONLY USE OF STEEL FASTENERS CAN RESULT IN A DIRECT BLOW CREATING A RANDOM S...

Страница 32: ...ation STATICALLY CONDUCTIVE DUCT MAINTENANCE Special air ducts are fabricated from a statically conductive material to dissipate static electrical charges through the ground wire of the power source c...

Страница 33: ...of the amount of usage A typical scheduled maintenance program for a statically conductive duct would include but not be limited to the following 1 Clean and visually inspect each component of the duc...

Страница 34: ...nst the effects of corrosion and damage If the Blower is not to be operated for a period of 30 days or more proceed to store as follows 1 Clean all accumulated dirt and grease from the Blower utilizin...

Страница 35: ...been made to provide data questions inevitably arise In these circumstances contact the Customer Service Department of General Equipment Company for technical assistance Our staff of technical personn...

Страница 36: ...r vapors that may travel at low levels for a considerable distance to sources of ignition CAUTION certain substances while perhaps not extremely hazardous in pure states react violently with other mat...

Страница 37: ...on sources of ignition such as welding sparks open flame and hot filaments of light bulbs Definition of Combustible Dust NFPA defines a combustible dust as one with an Ignition Sensitivity equal to or...

Страница 38: ...dust Moisture content of dusts affects electrical conductivity Minimum Explosion Concentration As with gases there are limiting concentrations of dusts within which an explosion can or can not occur N...

Страница 39: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 37...

Страница 40: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 38...

Страница 41: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 39...

Страница 42: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 40...

Страница 43: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 41...

Страница 44: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 42...

Страница 45: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 43...

Страница 46: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 44...

Страница 47: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 45...

Страница 48: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 46 Service Parts Section EP8HL Hazardous Location Ventilation Blower...

Страница 49: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 47 EP8HL Series Portable Ventilating Blower...

Страница 50: ...inum Nut Hexagon 10 24 UNC Aluminum Screw Machine C S 10 24 UNC x 5 8 Aluminum Screw Cap 1 4 20 UNC x 1 Aluminum Pin Cotter 3 32 x 3 4 Stainless Screw Allen Special Stainless Washer Flat Number 10 Alu...

Страница 51: ...1051000 30050400 SG24 5072 999 7 Nut Tinnerman 10 24 Plate Switch ON OFF Plate Serial Number Flow Rate Plate Danger French Plate Danger English Plate Electrical Information Decal General Washer Flat 1...

Страница 52: ...EP8HL HAZARDOUS BLOWER FORM GOM7069501 VERSION 1 2 50 EP8HL Series Portable Ventilating Blowers Hose Storage Cannisters...

Страница 53: ...D 5010W Cannister Blower Duct For Use On SCHL815 Cannister Cannister Blower Duct For Use On SCHL825 Cannister Handle Hose Latch Cannister With Keeper Screw Cap Button Socket Head 10 24 x 1 2 Plated Sc...

Отзывы: