4.4.4 L-Band Status
{aaS3}
Returns: {S3bbCddTReeN}
Where:
bb = 2 Chars., LNB current Detection
Range: 00 to 99 ( 0 - 990 mA)
C = 1 Character, SSPB Band Control
Range: 0 = low band, 1 = high band
dd
=
2
Characters,
SSPB
Gain
Range: –8 to –0 or ++ (dB) ++ = Full On
T
=
1
Character,
Up/Converter
enable
Range:
0
=
disable,
1
=
enable
R
=
1
Character,
Down/Converter
enable
Range:
0
=
disable,
1
=
enable
ee = 2 Character, SSPB current detection
Range: 00 to 30 (0 – 3.0 A)
N = 0 for SSPB Disable, 1 SSPB Enable
4.4.5 Set Cable Slope Factor
{aaFx}
Where:
x
=
numeric
character
Range:
0
to
5
(dB/500
MHz)
4.4.6 Query Cable Slope Factor
{aaF}
Returns:
{F = x}
Where:
x
=
numeric
character
Range:
0
to
5
(dB/500
MHz)
4.4.7 Serial Number Read
{aaID}
Returns: {aaIDyymmddxxxx}
Where
:
yy = last 2 digits of year
mm = month
dd
=
day
xxxx
=
4
digit
sequence
number
4.4.8 Query Software Version
{aaV}
Returns: {aaVr.ii}
Where:
r = Software Release number (1 – 9)
ii = Software Issue number (00 – 99)