2

Never use the generator or any of its parts as a step. Stepping 

• 

on the unit can stress and break parts, and may result in 

dangerous operating conditions from leaking exhaust gases, 

fuel leakage, oil leakage, etc.

On electric start models, disconnect the POSITIVE (+) battery 

• 

cable from the engine starter OR the NEGATIVE (-) battery 

cable from the battery terminal, whichever is easier, before 

transporting the generator. 

NOTE:

This generator is equipped with a spark arrestor muffler. The 

spark arrestor must be maintained in effective working order 

by the owner/ operator. In the State of California, a spark 

arrestor is required by law (Section 4442 of the California 

Public Resources Code). Other states may have similar laws. 

Federal laws apply on federal lands. 

EXHAUST & LOCATION HAZARDS

Never operate in an enclosed area or indoors! 

• 

NEVER use in 

the home, or in partly enclosed areas such as garages, even 

if doors and windows are open! ONLY use outdoors and far 

from open windows, doors, vents, and in an area that will not 

accumulate deadly exhaust.

The engine exhaust fumes contain carbon monoxide, which 

• 

can you cannot see or smell. This poisonous gas, if breathed 
in sufficient concentrations, can cause unconsciousness or 
even death.

Adequate, unobstructed flow of cooling and ventilating air 

• 

is critical to correct generator operation. Do not alter the 
installation or permit even partial blockage of ventilation 
provisions, as this can seriously affect safe operation of the 
generator. The generator MUST be operated outdoors. 

This exhaust system must be properly maintained. Do nothing 

• 

that might render the exhaust system unsafe or in noncompliance 

with any local codes and/or standards.

Always use a battery operated carbon monoxide alarm indoors, 

• 

installed according to the manufacturers instructions.

If you start to feel sick, dizzy, or weak after the generator has 

• 

been running, move to fresh air IMMEDIATELY. See a doctor, as 
you could have carbon monoxide poisoning.

ELECTRICAL HAZARDS

The 

• 

generator produces dangerously high voltage when in 

operation. Avoid contact with bare wires, terminals, connections, 

etc., while the unit is running, even on equipment connected 

to the generator. Ensure all appropriate covers, guards and 

barriers are in place before operating the generator. 

Never handle any kind of electrical cord or device while 

• 

standing in water, while barefoot or while hands or feet are wet. 

DANGEROUS ELECTRICAL SHOCK MAY RESULT.

The National Electric Code (NEC) requires the frame and external 

• 

electrically conductive parts of the generator be properly 

connected to an approved earth ground. Local electrical codes 

may also require proper grounding of the generator. Consult 

with a local electrician for grounding requirements in the area.

Use a ground fault circuit interrupter in any damp or highly 

• 

conductive area (such as metal decking or steel work).

Do not use worn, bare, frayed or otherwise damaged electrical 

• 

cord sets with the generator.

Before performing any maintenance on the generator, disconnect  

• 

the engine starting battery (if equipped) to prevent accidental 

start up. Disconnect the cable from the battery post indicated 

by a NEGATIVE, NEG or (–) first. Reconnect that cable last.

In case of accident caused by electric shock, immediately shut 

• 

down the source of electrical power. If  this is not possible, 
attempt to free the victim from the live conductor. 

AVOID 

DIRECT CONTACT WITH THE VICTIM. 

Use a non-conducting 

implement, such as a rope or board, to free the victim from the 
live conductor. If the victim is unconscious, apply first aid and 
get immediate medical help.

FIRE HAZARDS

Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE

• . 

Do not permit smoking, open flames, sparks or heat in the 
vicinity while handling gasoline. 

Never add fuel while unit is running or hot. Allow engine to cool 

• 

completely before adding fuel.

Never fill fuel tank indoors. 

• 

Comply with all laws regulating 

storage and handling of gasoline.

Do not overfill the fuel tank. Always allow room for fuel 

• 

expansion. 

If tank is over-filled, fuel can overflow onto a hot 

engine and cause FIRE or an EXPLOSION. Never store generator 

with fuel in tank where gasoline vapors might reach an open 

flame, spark or pilot light (as on a furnace, water heater or 

clothes dryer). FIRE or EXPLOSION may result. Allow unit to 

cool entirely before storage.

Wipe up any fuel or oil spills immediately. Ensure that no 

• 

combustible materials are left on or near the generator. Keep the 
area surrounding the generator clean and free from debris and 
keep a clearance of five (5) feet on all side to allow for proper 
ventilation of the generator.

Safety Rules

Содержание XG Professional Series

Страница 1: ...www generac com or 1 888 436 3722 Owner s Manual XG Professional Series 6 500 8 000 Watt Portable Generator MODELS 005796 0 XG6500 005797 0 XG7000 005798 0 XG7000E 005800 0 XG800 005747 0 XG8000E...

Страница 2: ...Adding Gasoline 9 2 8 To Start the Engine 10 2 8 1 Manual Recoil Starting 10 2 8 2 Electric Starting XG7000E XG8000E 11 2 9 Stopping the Engine 11 2 10 Low Oil Pressure Shutdown System 11 2 10 1 Resta...

Страница 3: ...US SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY Indicates a hazardous situation or action which if not avoided could result in death or serious injury Indicates a ha...

Страница 4: ...ds and barriers are in place before operating the generator Never handle any kind of electrical cord or device while standing in water while barefoot or while hands or feet are wet DANGEROUS ELECTRICA...

Страница 5: ...NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 University Ave...

Страница 6: ...ne at 1 888 775 6937 1 2 1 ASSEMBLING THE WHEEL KIT AND FRAME FOOT The wheel kit is designed to greatly improve the portability of the generator You will need the following tools to install the wheel...

Страница 7: ...o reset circuit breaker to protect the generator against electrical overload 8 Circuit Breakers AC The 30 Amp receptacle is protected with a pair of push to reset circuit breakers to protect the gener...

Страница 8: ...interval providing a two hour window to perform service When the hour meter is in the Flash Alert mode the maintenance message will always alternate with elapsed time in hours and tenths The hours wil...

Страница 9: ...y and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency h...

Страница 10: ...ading the unit Add up the total wattage of all electrical devices to be connected at one time This total should NOT be greater than the generator s wattage capacity The rated wattage of lights can be...

Страница 11: ...minimum American Petroleum Institute API Service Class SJ SL or better Use no special additives Select the oil s viscosity grade according to the expected operating temperature also see chart Above 40...

Страница 12: ...r use engine or carburetor cleaner products in the fuel tank as permanent damage may occur 2 8 TO START THE ENGINE Never start or stop engine with electrical devices plugged into the receptacles AND d...

Страница 13: ...Y XG7000E XG8000E n Do not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery el...

Страница 14: ...the following Fuel System Air Induction System Fuel Tank Intake pipe manifold Fuel Cap Air cleaner Carburetor Ignition System Fuel Lines Spark plug Evaporative Control System Ignition module Carbon C...

Страница 15: ...hose and oil fill plug to drain oil completely into a suitable container When oil has completely drained install oil drain cap and tighten securely Place a suitable container beneath the oil filter an...

Страница 16: ...it for storage NEVER store engine with fuel in tank indoors or in enclosed poorly ventilated areas where fumes may reach an open flame spark or pilot light as on a furnace water heater clothes dryer o...

Страница 17: ...charger included in the accessory box see the Charging a Battery section RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY The battery shipped with the generator has been provided fully charged To rep...

Страница 18: ...tuck open or closed 12 Engine has lost compression 1 Turn Fuel shut off ON 2 Clean or replace air cleaner 3 Fill fuel tank 4 Drain fuel tank and fill with fresh fuel 5 Connect wire to spark plug 6 Rep...

Страница 19: ...17 Notes...

Страница 20: ...market parts not made supplied or approved by Generac You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs The warranty repairs should be completed in a...

Страница 21: ...t repaired or replaced under the ECS warranty shall be warranted for the remainder of the period prior to the first scheduled replacement point for that part 4 Repair or replacement of any warranted e...

Страница 22: ...nostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Systems Failures due but not limited to normal wear and tear accident misuse...

Страница 23: ...or 1 888 436 3722 Manual del propietario XG Professional Series Generador port til de 6 500 8 000 vatios MODELO 005796 0 XG6500 005797 0 XG7000 005798 0 XG7000E 005800 0 XG800 005747 0 XG8000E 2A OS G...

Страница 24: ...11 Mantenimiento 11 3 1 Cronograma de mantenimiento 11 3 2 Especificaciones del producto 11 3 2 1 Especificaciones del generador 11 3 2 2 Especificaciones del motor 12 3 2 3 Informaci n sobre emision...

Страница 25: ...ca una situaci n peligrosa o acci n que si no se evita podr a traer como resultado la muerte o un da o serio CUIDADO Indica una situaci n peligrosa o acci n que si no se evita puede traer como resulta...

Страница 26: ...nerador Aseg rese que todas las cubiertas protecciones y barreras apropiadas se encuentren en su lugar antes de operar el generador No manipule ningun tipo de dispositivo el ctrico mientras est de pie...

Страница 27: ...res c digos regulaciones o leyes pertinentes la informaci n publicada listada abajo puede usarse como gu a para la operaci n de este equipo Siempre consulte la revisi n m s reciente aplicable para el...

Страница 28: ...888 775 6937 1 2 1 ENSAMBLAJE DE LA RUEDA El kit de la rueda est dise ado para mejorar en gran medida la portabilidad del generador Usted necesitar las siguientes herramientas para instalar el kit de...

Страница 29: ...provisto con un interruptor de circuito de presionar para reiniciar con el fin de proteger al generador contra sobrecargas el ctricas 8 Interruptores de circuito AC El recept culo de 30 amps est prote...

Страница 30: ...as est en el modo de alerta de destello Flash Alert el mensaje de mantenimiento siempre alternara con el tiempo transcurrido en horas y d cimos Las horas destellar n cuatro veces luego alternar con lo...

Страница 31: ...o de CA en el panel de control del generador a trav s de un cable jumper Requerimientos especiales Puede haber regulaciones federales o estatales respecto a la salud y seguridad ocupacional OSHA c dig...

Страница 32: ...del generador La potencia nominal de las luces puede leerse en las mismas bombillas La potencia nominal de las herramientas aparatos y motores normalmente se puede encontrar en la etiqueta de datos o...

Страница 33: ...de la toma de aceite y retire la tapa Llene lentamente el motor con aceite a trav s de la abertura hasta que llege a su marca de lleno Deje de llenar ocasionalmente para revisar el nivel de aceite El...

Страница 34: ...siga la misma secuencia de choke listada arriba NOTA Si el motor dispara pero no sigue funcionando tire la palanca de choke a Full Choke y repita las instrucciones de arranque IMPORTANTE No sobrecarg...

Страница 35: ...panel de control cuando el generador vaya a usarse NOTA No use el cargador dem bater as por m s de 48 horas en una carga 3 1 CRONOGRAMA DE MANTENIMIENTO Siga los intervalos del calendario Se requiere...

Страница 36: ...o negligencia del operador Para recibir el valor total de la garant a el operador debe hacer el mantenimiento del generador tal como se instruye en este manual Se necesitar hacer algunos ajustes perio...

Страница 37: ...ado 3 3 6 REEMPLAZO DE LA BUJ A Use buj as Champion RC14YC o equivalentes Reemplace la buj a una vez al a o Esto ayudar a que el motor arranque con mayor facilidad y funcione mejor 1 Detenga el motor...

Страница 38: ...de cidos durante el almacenamiento Los gases cidos pueden da ar el sistema de combustible de un motor durante el almacenamiento Para evitar problemas con el motor el sistema de combustible deber vacia...

Страница 39: ...apropiados en exteriores lejos de las flamas abiertas Aseg rese de que el motor est fr o No fume en la cercan a ni encienda cigarro alguno Presione la v lvula de combustible del panel de control y ret...

Страница 40: ...de combustible a ON 2 Limpie o reemplace el limpiador de aire 3 Llene el tanque de combustible 4 Drene y llene el tanque de combustible con gasolina fresca 5 Conecte el cable a la buj a 6 Reemplace l...

Страница 41: ...17 Notas...

Страница 42: ...epuestos falsos o del mercado negro no fabricados suministrados o aprobados por Generac Usted es responsable de contactar a un concesionario autorizado de garant a de Generac tan pronto se presente el...

Страница 43: ...mer punto de reemplazo programado para aquella parte 4 La reparaci n o reemplazo de cualquier parte garantizada relacionada a las emisiones bajo esta garant a ECS deber realizarse sin costo alguno par...

Страница 44: ...ferentes a los concesionarios autorizados por Guardian Generac que no est n autorizados por escrito por Generac Power Systems Fallas debido a pero no limit ndose a el uso y desgaste normal accidente m...

Отзывы: