Owner’s Manual for Generac PWRcell Inverter

General Information

Internet LED

Internet  LED  (G)  is  illuminated  when  the  inverter  is

connected  to  a  router  and  has  an  IP  address.  See

Ethernet Configuration

.

NOTE: 

A  blue  Internet  LED  does  not  mean  that  the

inverter has a connection to with the Generac server.

Shutdown Mode

NOTE: 

A loss of grid power will not de-energize REbus

in  a  PWRcell  system  configured  to  island  with  enabled

energy storage.
Shutdown button  (E)  activates  a  transition  to  shutdown

system mode. Use of the shutdown system mode is only

intended for servicing and troubleshooting equipment. It

is not intended to be utilized to meet NEC rapid shutdown

requirements. 

Shutdown  mode  signals  all  communicating  PWRcell

equipment on REbus, including the PWRcell inverter, to

disable.  Disabled  PWRcell  equipment  will  drop  their

output voltages to safe levels. 
To enter shutdown, press and hold shutdown button (E). 
In shutdown mode:

PWRcell  inverter  will  stop  sourcing  power  to

REbus, and immediately disable all communicating

power  sources  on  REbus  by  sending  a  system-

wide system mode change signal.

NOTE: 

  Successful  signal  transmission  relies  upon

proper  configuration  of  PLM  channels  across  REbus

devices (PV Links and Batteries).

Shutdown LED (F) will illuminate.

Disabled PWRcell batteries will open their REbus

contacts.

Inverter screen (A) will display REbus DC bus volt

-

age  and  text  indicting  shutdown  mode  has  been

initiated.

NOTE: 

The  AC  section  of  the  inverter  will  still  be

energized  unless  the  building  AC  disconnect  or  main

service breaker is shut off.

System Modes Overview

Generac  PWRcell  offers  several  system  modes  for  various  installation  configurations,  markets,  and  applications.

Connected REbus devices work together to manage the distribution of power based on the selected system mode. 
Some modes interact with PWRcell batteries to store power and/or balance production and consumption. 
See 

Table 2-1

 and 

Table 2-2

 for an overview of available system modes.

Grid Tie

In  Grid  Tie  mode,  the  PWRcell  inverter  functions  as  a

conventional  grid-tied  inverter  system.  The  system

powers  local  loads  and  when  generation  exceeds  load

demand,  excess power is  exported  to the  utility for net

metering and other credits.

NOTE: 

Grid Tie is intended for use with systems that do

not  include  a  PWRcell  battery.  For  systems  where  a

PWRcell battery will be connected at a later date, operate

in Grid Tie mode until the battery is installed.

(000600)

DANGER

Electrocution. Initiate a system-wide shutdown and turn the 
PWRcell DC Disconnect Switch OFF on all connected 
batteries before performing service. Failure to do so will 
result in death, serious injury, or equipment and property 
damage.

Table 2-1. Most Common System Inverter Modes

Priority

Grid Tie

Clean Backup

Priority Backup

Self Supply

   1

Support local loads

Charge batteries from bus

Charge batteries from bus

Support local loads

   2

Export to grid

Support local loads

Charge batteries from grid

Charge batteries from bus

   3

-

Export to grid

Support local loads

Export to grid

   4

-

-

Export to grid

-

Table 2-2. Optimal Configuration for Goal

Goal

Optimal Inverter Configuration

Keep batteries charged as much as possible

Priority Backup

Keep batteries charged using only solar power

Clean Backup

Net-metering solar energy without a battery

Grid Tie

Use grid as little as possible

Self Supply

Содержание PWRcell XVT076A03

Страница 1: ...life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at https pwrfleet generac com 1 888 GENERAC 888 436 3722 Para español visita http www generac com service support product support lookup Pour le français visiter http www generac com service support product suppo...

Страница 2: ...ge See Serial Number Locations When contacting an Independent Authorized Service Dealer IASD or Generac Customer Service always supply the complete model number and serial number of the unit Table 1 Generac PWRcell Inverter Important Information Unit Model Number Unit Serial Number Date Purchased Commissioning Date 000393a WARNING CANCER AND REPRODUCTIVE HARM www P65Warnings ca gov ...

Страница 3: ...ter LED 7 Internet LED 8 Shutdown Mode 8 System Modes Overview 8 Grid Tie 8 Clean Backup 9 Priority Backup 9 Self Supply 9 Self Supply Setpoints 10 Section 3 Operation 13 Operation and User Interface 13 Home Screen 13 Selecting System Modes 13 Device Pages 14 Enabling and Disabling Devices 14 Mod Settings Menu 15 Ethernet Configuration 17 Ethernet Setup 17 Serial Number and Registration 17 Other E...

Страница 4: ...iv Owner s Manual for Generac PWRcell Inverter This page intentionally left blank ...

Страница 5: ...on tags and decals affixed to the unit are not all inclusive If using a procedure work method or operating technique that the manufacturer does not spe cifically recommend verify that it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special inst...

Страница 6: ...matic start up Disconnect utility power and render unit inoperable before working on unit Failure to do so will result in death or serious injury WARNING Risk of injury Do not operate or service this machine if not fully alert Fatigue can impair the ability to service this equipment and could result in death or serious injury 000215 000209b WARNING Loss of life This product is not intended to be u...

Страница 7: ...irst aid and get medical help Failure to do so will result in death or serious injury 000599 Electrocution Turn battery disconnect OFF and de energize REbus before touching terminals Failure to do so will result in death serious injury equipment and property damage DANGER 000152 DANGER Electrocution Verify electrical system is properly grounded before applying power Failure to do so will result in...

Страница 8: ...Introduction and Safety 4 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...

Страница 9: ...ating AC 1 Operating voltage range AC XVT076A03 L N V rms 108 120 130 Operating voltage range AC XVT076A03 L L V rms 216 240 260 Operating voltage range AC XVT114G03 L N V rms 108 120 130 Operating output voltage range AC XVT114G03 L L V rms 184 208 228 Continuous output current AC grid tied A rms 32 PCS controlled current grid tied Arms 32 Continuous output current AC islanded A rms 42 Output fau...

Страница 10: ...wer PWRcell inverters disconnect from the grid and provide AC power to support protected loads when configured to do so All PWRcell products use the REbus 380 VDC nanogrid to connect to each other The REbus nanogrid automates the flow of power to enable plug and play setup and operation of PWRcell equipment For more information about REbus visit www generac com In Figure 2 3 PWRcell inverter E is ...

Страница 11: ...ific fault detected Inverter LED Inverter LED D communicates the status of the utility grid and or inverter through LED color and state Green utility is connected and within normal operational voltage and frequency Yellow utility grid is not within normal conditions and the inverter is in a waiting state User intervention typically is not required The inverter will restart as soon as the utility g...

Страница 12: ...Modes Overview Generac PWRcell offers several system modes for various installation configurations markets and applications Connected REbus devices work together to manage the distribution of power based on the selected system mode Some modes interact with PWRcell batteries to store power and or balance production and consumption See Table 2 1 and Table 2 2 for an overview of available system mode...

Страница 13: ...ar power is used to charge the battery When the available solar power is lower than the battery input power rating the inverter uses grid power to expedite battery charging See Figure 2 8 If solar and grid power are available both can charge the battery The system displays the amount of power being drawn from the grid and the amount of power being consumed by local loads before reaching the batter...

Страница 14: ... Self Supply mode only and are only used for specific applications See Table 2 3 Self Supply Setpoints 009962 009963 011241 Table 2 3 Self Supply Setpoints Setpoint Description Default Units TargMaxImprtP Target Maximum Import Power Maximum power imported from the grid at any point When the overall building load exceeds this setpoint the inverter will supply additional power from the battery and s...

Страница 15: ...information on CT calibration see the PWRcell Inverter Installation Manual NOTE This feature is NOT intended to serve as a means of achieving compliance to Utility interconnection requirements For information on export limiting settings related to Utility compliance see the PWRcell Inverter Installation Manual When enabled Export Override allows the user to restrict inverter export such that exces...

Страница 16: ...12 Owner s Manual for Generac PWRcell Inverter General Information This page intentionally left blank ...

Страница 17: ...he current system mode is displayed at the top of the screen Figure 3 2 Home Screen Selecting System Modes Once a system is installed a system mode that best suits the user s needs must be set Once set the system remains in that mode without needing to be changed NOTE A system mode can be changed at any time To select a system mode 1 See Figure 3 3 While viewing the home screen press the center bu...

Страница 18: ... enabled by the user before the device will operate If a device is disabled the device will remain in a disabled state and will not resume operation until enabled by the user Once enabled if grid power is present the inverter will create DC voltage establishing the REbus nanogrid All devices connected to REbus will wake up and begin communications To enable a device 1 Use the right arrow key to sc...

Страница 19: ...r button to select Figure 3 11 Internet Device Page NOTE After selecting Mod Settings it may take a moment for the settings to load 3 See Figure 3 12 Use the up and down arrows to scroll through available settings 4 Highlight the desired setting and press the center button to select 5 Use the up and down arrow keys to adjust the value of the setting NOTE Press the center button to deselect a setti...

Страница 20: ...ding backup power during a grid outage EnaExtTransfer on or off off Turn on if an external automatic transfer switch ATS has been installed to operate with the Inverter ExtTransVolt 50 0 200 0 95 Minimum voltage from the utility that must be present for the inverter to reconnect an ATS back to the grid ExtTransTime 1 360 Seconds 15 Length of time the inverter will wait to trigger an ATS to reconne...

Страница 21: ...e can be monitored from the PWRview online monitoring system and mobile app To register a system for PWRview monitoring 1 See Figure 3 13 Locate the serial number and registration code on the registration decal on the front of the inverter This information will be required for registration 2 Navigate to https pwrfleet generac com or if using a mobile device scan the registration label QR code 3 Fo...

Страница 22: ...Operation 18 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...

Страница 23: ...vent B are clear at all times Cleaning Intake Filter See Figure 4 1 Clean intake filter A with a soft brush or vacuum cleaner If air filter is damaged or becomes difficult to clean contact the nearest Independent Authorized Service Dealer IASD or Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www generac com for a replacement filter Figure 4 1 Intake Vent and Exhaust Vent Recove...

Страница 24: ...rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290 Hwy 59 Waukesha WI 53189 1 888 GENERAC 1 888 436 3722 www generac com ...

Отзывы: