Thank  you  for  purchasing  a  Generac  PWR

-

cell

®

 product.

This manual provides instructions for installing

PV  Link  and  SnapsRS  devices.  Consult  the

installation  and  operation  manuals  for  other

Generac  PWRcell  system  components,  as

applicable.

The  information  in  this  manual  is  accurate

based  on  products  produced  at  the  time  of

publication.  The  manufacturer  reserves  the

right  to  make  technical  updates,  corrections,

and  product  revisions  at  any  time  without

notice.

If any section of this manual is not understood,

contact  the  nearest  Independent  Authorized

Service  Dealer  (IASD)  or  Generac  Customer

Service  at  1-888-436-3722  (1-888-GEN

-

ERAC), or visit 

www.generac.com

 for assis

-

tance.  The  owner  is  responsible  for  correct

maintenance and safe use of the unit.

This manual must be used in conjunction with

all  other  supporting  product  documentation

supplied with the product.

SAVE THESE INSTRUCTIONS for future ref

-

erence.  This  manual  contains  important

instructions  that  must  be  followed  during

placement, operation, and maintenance of the

unit  and  its  components. Always  supply  this

manual to any individual that will use this unit,

and  instruct  them  on  how  to  correctly  start,

operate,  and  stop  the  unit  in  case  of  emer

-

gency.

Safety Rules

The  manufacturer  cannot  anticipate  every

possible  circumstance  that  might  involve  a

hazard. The alerts in this manual, and on tags

and decals affixed to the unit, are not all inclu

-

sive.  If  using  a  procedure,  work  method,  or

operating  technique  that  the  manufacturer

does not specifically recommend, verify that it

is  safe  for  others  and  does  not  render  the

equipment unsafe.

Throughout  this publication,  and on tags and

decals  affixed  to  the  unit,  DANGER,  WARN

-

ING, CAUTION, and NOTE blocks are used to

alert personnel to special instructions about a

particular operation that may be hazardous if

performed  incorrectly  or  carelessly.  Observe

them carefully. Alert definitions are as follows:

NOTE: 

Notes  contain  additional  information

important  to  a  procedure  and  will  be  found

within the regular text of this manual.
These safety alerts cannot eliminate the haz

-

ards  that  they  indicate.  Common  sense  and

strict compliance with the special instructions

while  performing  the  action  or  service  are

essential to preventing accidents.

How to Obtain Service

For  assistance,  contact  the  nearest  Indepen

-

dent  Authorized  Service  Dealer  (IASD)  or

Generac  Customer  Service  at  1-888-GEN

-

ERAC (1-888-436-3722), or visit 

www.generac.com

.

 

When contacting Generac Customer Service,

always supply the complete model and serial

number of the unit as given on its data decal

located  on  the  unit.  Record  the  model  and

serial numbers in the spaces provided on the

front cover of this manual.

(000100a)

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product 
could result in death or serious injury.

WARNING

(000001)

DANGER

Indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

(000002)

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.

(000003)

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

Содержание PV Link 010023

Страница 1: ...d in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at https pwrfleet generac com 1 888 GENERAC 888 436 372...

Страница 2: ...ty to perform all safety checks to verify that all maintenance for safe operation is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacem...

Страница 3: ...ormation 7 Component Locations 7 Section 3 Installation Design 9 Installation Design Worksheet 9 Section 4 PVRSS Compliance Guidelines 11 Section 5 Mounting and Connecting 13 Installation Guidelines 1...

Страница 4: ...This page intentionally left blank...

Страница 5: ...erating technique that the manufacturer does not specifically recommend verify that it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals af...

Страница 6: ...o ensure the completed PV system meets the rapid shutdown functional requirements This equip ment must be installed according to the manu facturer s installation instructions 000191 DANGER Automatic s...

Страница 7: ...s injury equipment and property damage DANGER 000152 DANGER Electrocution Verify electrical system is properly grounded before applying power Failure to do so will result in death or serious injury 00...

Страница 8: ...4 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 9: ...voltage VDC 420 open circuit Nominal output REbus DC nanogrid 380 VDC data Maximum output current continuous A 8 Standby power W 1 Topology Boost converter Protections Ground fault protection arc fau...

Страница 10: ...nk is intended for use with 60 cell 72 cell or 96 cell residential DC solar modules Solar modules must not require positive or negative grounding as this would interfere with PLC communications NOTE O...

Страница 11: ...NEC requires rapid shutdown only on the conductors leaving the PV array The 2017 and 2020 NEC require rapid shutdown at the PV module level and on the conductors leaving array PV Link is a PV rapid sh...

Страница 12: ...8 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 13: ...e limit 3 Divide the PV Link Vmp Voltage at Maxi mum Power by the panel Vmp and round down to determine the number of panels that can be connected in series to the PV Link without exceeding maximum po...

Страница 14: ...10 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 15: ...cation of the PVRSS initiator and its labeling To meet 2017 and 2020 compliance 1 The 2017 and 2020 NEC requires the PVRSS initiator be located at a readily accessible location outside the building Th...

Страница 16: ...12 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 17: ...G ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OFTHIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRIC SHOCK HAZARD DC OUTPUT CONDUCTORS MAY BE ENERGIZED REGARDLESS OF SUN EXPOSURE CAUTION...

Страница 18: ...lation or flagging Mark negative REbus field wiring leads with blue insulation or flagging Connect multiple optimizers in parallel using MC4 branch connectors or a com biner box Connecting PV Modules...

Страница 19: ...he input of the PV Link NOTE Install SnapRS devices prior to secur ing PV modules to the racking To install SnapRS devices 1 See Figure 5 5 For each PV module in the PV string connect the positive end...

Страница 20: ...st be one SnapRS device for each module in the array Additionally the String Count set ting on the PV Link device page must be set to 2 Figure 5 6 Single PV Substring with Parallel Series Inputs and S...

Страница 21: ...s Manual for more information on sys tem modes and commissioning To enable and commission PV Link Ensure REbus are connected with correct polarity to each PV Link Ensure each PV Link has a low resis t...

Страница 22: ...cription PLM Channel 1 12 1 Channel for REbus communications All devices in a sys tem must use the same channel except REbus Beacon Vin Strartup 60 135 Volts 135V Minimum input voltage from the PV sub...

Страница 23: ...orking properly When an arc fault is detected the status message reads Arc Fault To conduct an AFD test 1 On the PWRcell Inverter control panel use the left or right arrows to scroll to the page for t...

Страница 24: ...20 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 25: ...ce If the PV Link is not operating as expected or if a PV Link error message appears on the Generac PWRcell Inverter control panel LCD display contact the nearest Independent Authorized Service Dealer...

Страница 26: ...22 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 27: ...Polarity Check REbus Wiring Ground May Need to Check REbus Fuses Known PV Link Offline A PV Link that has communicated with the inverter previously shows offline at its device page when it s connecti...

Страница 28: ...performed on SnapRS devices in the field However some simple digital multimeter DMM checks can confirm the general health of a SnapRS device DMM Red to SnapRS DMM Black to SnapRS Resistance reads 300...

Страница 29: ...Installation Manual for PV Link and SnapRS 25 This page intentionally left blank...

Страница 30: ...26 Installation Manual for PV Link and SnapRS This page intentionally left blank...

Страница 31: ......

Страница 32: ...ights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Отзывы: