Generac Power Systems MLTS Скачать руководство пользователя страница 2

ii

Use this page to record important information about your light tower

Record the information found on your unit data label on
this  page.  See  unit  serial  number  location  (

Unit Serial

Number Locations

).  The  label  plate  is  affixed  to  the

inside partition, to the left of the control panel console. 
Engine  and  generator  serial  numbers  are  located  on
separate data plates affixed to the engine and generator.
When  contacting  a  Generac  Mobile Authorized  Service
Dealer  (GMASD)  about  parts  and  service,  supply  the
complete model number and serial number of the unit.

Operation and Maintenance:

 Proper maintenance and

care  of  the  light  tower  ensures  a  minimum  number  of
problems and keeps operating expenses at a minimum. It
is  the  operator’s  responsibility  to  perform  all  safety
checks, to verify that all maintenance for safe operation is
performed promptly, and to have the equipment checked
periodically by a GMASD. Normal maintenance, service
and  replacement  of  parts  are  the  responsibility  of  the
owner  or  operator  and,  as  such,  are  not  considered
defects  in  materials  or workmanship  within the terms of
the warranty. Individual operating habits and usage may
contribute  to  the  need  for  additional  maintenance  or
service.

Unit Model No.

Unit Serial No.

Engine Model No.

Engine Serial No.

Generator Model No.

Generator Serial No.

(000394)

WARNING

Breathing diesel engine exhaust exposes you 
to chemicals known to the State of California
to cause cancer and birth defects or other 
reproductive harm.
• Always start and operate the engine in a 
  well-ventilated area.
• If in an enclosed area, vent the exhaust to 
  the outside.
• Do not modify or tamper with the exhaust 
  system.
• Do not idle the engine except as necessary.
For more information go to 

www.P65Warnings.ca.gov/diesel.

(000393a)

WARNING

CANCER AND REPRODUCTIVE HARM

www.P65Warnings.ca.gov.

Содержание MLTS

Страница 1: ...SAVE THIS MANUAL FOR FUTURE REFERENCE For technical assistance contact www generacmobileproducts com Technical Service 1 800 926 9768 Owner s Manual Light Tower MLTS 008615 ...

Страница 2: ...for safe operation is performed promptly and to have the equipment checked periodically by a GMASD Normal maintenance service and replacement of parts are the responsibility of the owner or operator and as such are not considered defects in materials or workmanship within the terms of the warranty Individual operating habits and usage may contribute to the need for additional maintenance or servic...

Страница 3: ...ns 15 Component Locations 16 Control Panel 18 Section 3 Operation Light Tower Setup 19 Raising Mast Manual Winch 20 Raising Mast Electric Winch If Equipped 21 Prestart Checklist 22 Starting the Unit 22 Operating the Lights 23 Engine Derating 23 Customer Convenience Receptacles If Equipped 23 Load Limit and Overload 23 Shutting Down the Unit 23 Removing Loads from Receptacles If Equipped 23 Shuttin...

Страница 4: ...on 31 Maintenance 31 Electric Winch If Equipped Use Operation and Maintenance 31 Winch Mechanical Brake 31 Trailer Wheel Bearings 32 Jack Maintenance 32 Section 5 Troubleshooting General Troubleshooting 33 Troubleshooting the Lights 34 Section 6 Wiring Diagrams Mast Junction Box Wiring and Light Connec tions 35 AC Analog 1 of 2 36 AC Analog 2 of 2 37 DC Analog 38 ...

Страница 5: ...od or oper ating technique that the manufacturer does not specifically recommend verify that it is safe for others and does not render the equipment unsafe Throughout this publication and on tags and decals affixed to the unit DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or car...

Страница 6: ...Failure to do so could result in death or serious injury 000105 DANGER Explosion and Fire Fuel and vapors are extremely flammable and explosive Add fuel in a well ventilated area Keep fire and spark away Failure to do so will result in death or serious injury 000147 WARNING Risk of Fire Unit must be positioned in a manner that prevents combustible material accumulation underneath Failure to do so ...

Страница 7: ...188 DANGER Electrocution Do not wear jewelry while working on this equipment Doing so will result in death or serious injury DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or serious injury 000263a 000188 DANGER Electrocution Do not wear jewelry while working on this equipment Doing so will result in death or serious injury 000137a ...

Страница 8: ...ng Ambient air temperature is above 120 F 49 C Operating Safety Positioning the Unit The area immediately surrounding the unit should be dry clean and free of debris Position and operate the unit on a firm level surface If the unit is equipped with a frame grounding stud follow any local state and National Electrical Code NEC guidelines when connecting Starting the Unit 000192 DANGER Explosion and...

Страница 9: ...s Towing Safety Towing a trailer requires care Both the trailer and vehicle must be in good condition and securely fastened to each other to reduce the possibility of an accident Some states require that large trailers be registered and licensed Contact your local Department of Transportation office to check on license requirements for your particular unit Hitch and Coupling Verify the hitch and c...

Страница 10: ... speed is 10 mph 16 km h or less depending on terrain When towing maintain extra space between vehi cles and avoid soft shoulders curbs and sudden lane changes Reporting Trailer Safety Defects If you believe your trailer has a defect which could cause a crash or could cause injury or death you should immediately inform the National Highway Traffic Safety Administration NHTSA in addition to notifyi...

Страница 11: ...l not shown 2 Setup and Take Down Instructions Manual 17 Neutral Bonded to Frame 3 Danger Overhead Power Lines 18 Not A Step 4 Warning Electrical Storms and High Wind 19 Warning High Temperature Do Not Remove Guard 5 Owner s Manual Location 20 Mast Junction Box Wiring inside 6 Electric Shock Hazard 21 Warning Do Not Retract Outriggers With Tower Up 7 Warning Hot Surface 22 Stowed Position 8 Warnin...

Страница 12: ...8 Owner s Manual for Mobile Light Tower Introduction and Safety Figure 1 1 Decal Locations 1 of 3 1 Inch 25 mm 10000035325 0 5 0 5 1 Inch 25 mm 10000035402 008626 1 2 ...

Страница 13: ...PEMENT 4 NE PAS LAISSER LE MOTEUR TOURNER À VIDE PLUS QUE NÉCESSAIRE 5 POUR PLUS D INFORMATION ALLER À WWW P65WARNINGS CA GOV DIESEL 10000038540 WARNUNG ADVERTENCIA AVERTISSEMENT WARNING NEUTRAL BONDED TO FRAME NULLLEITER AM RAHMEN ANGESCHLOSSEN NEUTRO CONECTADO AL BASTIDOR POSITION NEUTRE LORSQUE FIXÉ AU CADRE CARBON MONOXIDE DANGER GEFAHR PELIGRO DANGER Débrancher la batterie avant de faire l en...

Страница 14: ...JDQFKH ODV FDGHQDV GH VHJXULGDG HQ IRUPD FUX DGD QJDQFKH DO YHKtFXOR OD FDGHQD GH HPHUJHQFLD SDUD DYHUtDV 5HYLVH ODV OXFHV GHO UHPROTXH 6 33 1 681 1 LUH OH PDQXHO GH O XWLOLVDWHXU 8WLOLVHU XQ DWWHODJH FRQYHQDQW DX SRLGV QRPLQDO EUXW GH OD UHPRUTXH UULPHU VROLGHPHQW OD UHPRUTXH DX YpKLFXOH WUDFWHXU 3RVHU OHV FKDvQHV GH VpFXULWp HQ OHV FURLVDQW L HU OD FKDvQH GH UHPRUTXDJH DX YpKLFXOH 9pULILHU OHV I...

Страница 15: ... Engine qt L 4 1 3 9 4 1 3 9 Oil Incl Filter qt L 3 5 3 4 3 5 3 4 Maximum Run Time Lights Only hr 190 190 Generator Make Model Marathon Electric 201CSA5430 Marathon Electric 201CSA5411 Power Output kW kVA 1 4 1 4 2 4 2 4 Output Voltage V 120 1Ø 120 1Ø Output Amperes A 11 6 20 Frequency Hz 60 60 AC Distribution Circuit Breaker Size A 15 20 Lighting Lighting Type Light emitting diode LED Light emitt...

Страница 16: ...e Products LLC DATE 00 0000 GVWR PNBV 000KG 0000LBS COLD INF PRESS PRESS DE V I N N I V 00000000000000000 TYPE TRAILER MODEL XXX000 GAWR PNBE TIRE PNEU RIM JANTE GONF A FROID KPA PSI LPC SGL DUAL EACH AXLE THIS VEHICLE CONFORMS TO ALL APPLICABLE STANDARDS PRESCRIBED UNDER THE U S FEDERAL MOTOR VEHICLE SAFETY STANDARDS FMVSS AND CANADIAN MOTOR VEHICLE SAFETY REGULATIONS IN EFFECT ON THE DATE OF MAN...

Страница 17: ...move jack from tongue weldment Hold jack vertically and extend until weldment on jack is aligned with tongue weldment 4 See Figure 2 3 Install jack and secure with clevis D Figure 2 3 Jack Installed 5 See Figure 2 2 Remove pins B and C 6 See Figure 2 4 Using both hands slowly lower trailer tongue into tow position NOTE Varying levels of effort may be required depending on terrain Figure 2 4 Lower ...

Страница 18: ...levels of effort may be required depending on terrain Figure 2 7 Pivot Trailer Tongue Into Storage Position 5 See Figure 2 8 Install pins B and C at locations shown to secure trailer tongue in storage position Figure 2 8 Install Pins and Rotate Jack 6 Remove clevis and remove jack A from tongue weldment 7 Completely retract jack 8 Rotate jack 90 counterclockwise place jack on tongue weldment and i...

Страница 19: ...Owner s Manual for Mobile Light Tower 15 General Information Unit Dimensions Figure 2 9 Unit Dimensions A B C D E 118 in 3 m 101 in 2 6 m 23 ft 7 m 10 ft 3 05 m 57 in 1 45 m A B C E D 009807 ...

Страница 20: ...ation Component Locations Figure 2 10 Component Locations Front and Left Side A Grounding stud E Tongue jack B Outrigger and Jack 2 locations F Mast rotation knob C Fuel fill G Winch D Tie down point 4 locations H Light 4 locations 008645 B F C D E D G H A ...

Страница 21: ... 17 General Information Figure 2 11 Component Locations Rear and Right Side J Central lift point M Tandem tow mount optional not shown K Engine radiator access hood N Hood latch L Forklift pocket P Key start controller J K L L M N P 008646 ...

Страница 22: ...trols export power if equipped C Light fixtures ON OFF switch One switch controls power to all light fixtures D Not used E Standard units Not used Units with electric winch Mast UP DOWN switch F Not used G Not used H 120 V duplex receptacle I Engine hour meter Displays how many hours engine has run J Engine ignition switch K Main circuit breaker A D E I J C F G B K H ...

Страница 23: ...ounding stud B is located on the rear frame of the trailer near the left side outrigger For ground ing requirements follow local state or National Electrical Code NEC guidelines 5 See Details C D Pull the locking pins C on the outriggers D and pull each outrigger out until the spring loaded locking pin snaps back into place Pull the locking pin on each outrigger jack F and rotate each jack 180 so ...

Страница 24: ...ing at the top sections of the mast Stop extending the mast when the colored mark D on the second mast section is visible as seen in Detail D Figure 3 2 Pulley Locations Manual Winch IMPORTANT NOTE Contact a GMASD immediately if the mast hangs up or the winch cable develops slack DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or ser...

Страница 25: ... A limit switch on the main mast section will disconnect power to the electric winch to prevent overextending the mast IMPORTANT NOTE Contact a GMASD immediately if the mast hangs up or the winch cable develops slack DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or serious injury 000263a WARNING 000266 Tipping hazard Extend the out...

Страница 26: ...and condition Inspect the engine fan belt guard Inspect the engine exhaust system for loose or rusted components Verify all covers are in place and secure Starting the Unit NOTE If the engine was run out of fuel or the fuel tank was drained it may be necessary to purge the fuel lines Refer to the engine operator s manual supplied with the unit 1 See Figure 2 12 Verify main circuit breaker and circ...

Страница 27: ...receptacle for powering accessories or tools Figure 3 8 Customer Convenience Receptacle The receptacle and a corresponding circuit breaker are located on the control panel See Figure 2 12 The receptacle is powered available for use when the engine is running and the main circuit breaker is ON I Load Limit and Overload Lights on Load limit 1 100 W Lights off Load limit 2 400 W Drawing more than the...

Страница 28: ...until the white arrows are aligned and the metal stop tabs are touching c Tighten the mast rotation knob Lowering the Mast Electric Winch If Equipped NOTE On key switch models key must be in RUN to operate electric winch 1 Press and hold the upper winch control switch downward to collapse the mast to its lowest position Verify the electrical cord does not get caught in or pinched by the mast while...

Страница 29: ...sing an internal valve and obstructing intake air Shutdown is triggered automatically by an output from the controller or manually by pulling the T handle B The reset knob C rotates 90 to block airflow If the knob is parallel to the pipe centerline as shown the valve is open If the knob is perpendicular to the pipe centerline the valve is closed and airflow is blocked Test the PAS Test the PAS at ...

Страница 30: ...ing to the unit in front B Inspect for proper operation of the directional and brake lights Connect the towing chains to the tie down locations C Avoid sharp turns when towing Do not cross any obstacles more than 12 in 30 5 cm deep Tandem tow speeds a Paved highway 45 mph 72 km h b Graded gravel 25 mph 40 km h c Cross country 10 mph 16 km h Telemetry If Equipped The digital telemetry option enable...

Страница 31: ... d Thirdpass tightento90 120ft lbs 122 162Nm NOTE After the first road use torque the lug nuts in sequence 8 Maximum recommended speed for highway towing is 45 mph 72 km h Recommended off road towing speed is not to exceed 10 mph 16 km h or less depending on the terrain Lifting the Unit Proceed as follows to prepare the unit for lifting 1 Verify the equipment being used to lift the unit is in good...

Страница 32: ...When securing the unit for transportation verify the equipment being used to fasten the unit is in good condition and has sufficient strength to hold the unit in place during transport See Figure 3 17 Use the tie down points C as shown Figure 3 17 Tie Down Points C 002538 ...

Страница 33: ...e of unauthorized use Cleaning the Unit Always clean the unit after each use to remove dust grease mud or spilled fuel or oil Use soft clean rags to wipe the cabinet exterior and control panel Low pressure compressed air less than 40 psi 276 kPa can also be used to remove dust and debris from the cabinet interior This unit contains sensitive electronic components that can be damaged by high pressu...

Страница 34: ... change intervals on the MLTS equipped with the Mitsubishi L2E Tier 4 engine be extended to 1 000 hours after initial break in The engine comes from the factory with a larger sump that holds 3 6 qts 3 4 L of engine oil After the initial 50 hour break in and oil change the sump coupled with the larger oil filter allows the engine to operate up to 1 000 hours between routine oil changes Hot humid or...

Страница 35: ...dically inspect all connections to verify they are tight and free of corrosion Inspect the cable for visible damage every time the winch is operated Examples of damage are cuts knots crushed or frayed portions and broken strands Replace cable immediately if damaged Failure to replace a damaged cable could result in breakage Regularly inspect the brake for slippage or drift This is detected visuall...

Страница 36: ... until fresh grease is visible around the nozzle of the grease gun 4 Wipe any excess grease from the axle hub with a clean cloth and replace the rubber plug The minimum recommended lubrication is every 12 months or 12 000 miles 19 312 km More frequent lubrication may be required under extremely dusty or damp operating conditions Every six months or depending on usage check for play in each bearing...

Страница 37: ...ion High coolant temperature shutdown Low coolant level Add coolant if needed Allow engine to cool then check coolant level in radiator Restart engine and check coolant temperature Stop engine immediately if coolant temperature is 210 F 99 C or more Blockage in radiator Inspect radiator shroud and ducting for blockage and remove any foreign matter Leakage in coolant hoses engine block or water pum...

Страница 38: ...ns inside the mast junction box and each mast light housing socket Damaged or loose electrical cord Inspect the mast electrical cord for damage and check the cord connections inside the control box Faulty fuel filter With engine running and lights off measure voltage and frequency at the GFCI receptacle Voltage should indicate 120VAC 5 and frequency should indicate 60 7 Hz 5 If frequency and volta...

Страница 39: ...Owner s Manual for Mobile Light Tower 35 Section 6 Wiring Diagrams Mast Junction Box Wiring and Light Connections 008713 1 3 2 4 ...

Страница 40: ...36 Owner s Manual for Mobile Light Tower Wiring Diagrams AC Analog 1 of 2 ...

Страница 41: ...Owner s Manual for Mobile Light Tower 37 Wiring Diagrams AC Analog 2 of 2 ...

Страница 42: ...38 Owner s Manual for Mobile Light Tower Wiring Diagrams DC Analog ...

Страница 43: ...T WT WT BK WT VI YL WT AMBER L AMBER R MARKER MARKER VI YL BK WT TO FUEL CKT BN BN BN WT WT WT RING GND LICENSE PLATE PANEL LIGHT BK WT BK WT BK BK WT WT BK BN BN WT BK BN BN BN WT BK BN WT BN WT WT BN BN SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPADE WT BN YL GN B C A D SPADE SPADE SPADE C B A D SPADE SPADE SPLICE SPLICE SPADE SPADE SPADE SPADE SPADE SPADE SPADE SPLICE SP...

Страница 44: ...40 Owner s Manual for Mobile Light Tower Wiring Diagrams This page intentionally left blank ...

Страница 45: ...Owner s Manual for Mobile Light Tower 41 Wiring Diagrams This page intentionally left blank ...

Страница 46: ...42 Owner s Manual for Mobile Light Tower Wiring Diagrams This page intentionally left blank ...

Страница 47: ......

Страница 48: ...ights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Mobile Products LLC Generac Mobile Products LLC 215 Power Drive Berlin WI 54923 GeneracMobileProducts com 800 926 9768 920 361 4442 ...

Отзывы: