Generac Portable Products MC10000 Extended Life Generator
4
KNOW YOUR GENERATOR
Read this owners manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
12 Volt DC Receptacle
Use this receptacle with
battery charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp GFCI Receptacle
May be
used to supply electrical power for the operation of 120
Volt AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads.
120 Volt AC, 20 Amp Locking Receptacle
May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle
May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle
May be used to supply electrical power for the
operation of 120 and/or 240 Volt AC, 30 Amp, single
phase, 60 Hz electrical lighting, appliance, tool and
motor loads.
120/240 Volt AC, 50 Amp Receptacle
May be used
to supply electrical power for the operation of 120/240
Volt AC, 50 Amp, single phase, 60 Hz electrical loads.
Air Cleaner
Used to limit the amount of dirt and
dust that gets in the engine.
Choke Lever
Used when starting a cold engine.
Circuit Breakers
(AC) Each receptacle is provided
with a "push to reset" circuit breaker to protect the
generator against electrical overload.
Fuel Tank
Holds 5 U.S. gallons of unleaded fuel.
Grounding Lug
Use this connection to properly
ground the generator.
Hour Meter
Displays actual unit operating time -
used to schedule routine maintenance.
Idle Control Switch
The idle control runs the
engine at normal (high) speeds when there is a load
present and runs the engine at idle (low) speeds when
a load is not present.
Ignition Switch
Must be set to ON () position to
start generator. To turn off generator, set switch to the
STOP (o) position.
Recoil Start Handle
Used to start the unit.
Spark Arrestor Muffler
(not shown) Exhaust
muffler lowers engine noise and is equipped with a
spark arrestor screen.
120 Volt AC, 20 Amp
GFCI Receptacle
Idle Control Switch
Ignition Switch
Hour Meter
Choke Lever
120 Volt AC, 30 Amp
Locking Receptacle
120 Volt AC, 20 Amp
Locking Receptacle
120/240 Volt AC,
50 Amp Receptacle
Circuit Breakers (AC)
120/240 Volt AC, 30 Amp
Locking Receptacle
12 Volt DC Receptacle
Air Cleaner
Fuel Tank
Grounding Lug
Recoil Start Handle