Generac Power Systems MC10000 Скачать руководство пользователя страница 17

Generac Portable Products MC10000 Extended Life Generator

17

Item Part #

Qty Description

1

NSP

1

ENGINE, Generac Power

Systems

2

93074

1

SHIELD, Heat Engine

3

77304

2

SUPPORT, Engine

4

90916

1

SHIELD, Heat-Stator

5

80270

1

VALVE, Fuel Shut-Off

6

78299

1

BUSHING, Fuel Valve

7

B4325

1

CAP, Fuel Tank

8

38353

8

MOUNTS, Vibration

9

78831B

4

CAPSCREW, M6-1.0 x 60mm

10

93615

1

TANK, Fuel

11

92558

1

CRADLE

12

83465

4

GROMMET, Fuel Tank

Mounting

13

56892

3

CRIMPTITE,  10-24 x 3/8"

14

23152

8

CAPSCREW, 3/8-16 x 3/4"

15

22237

16 WASHER, 3/8" Lock

16

22241

8

NUT, 3/8-16 Hex

17

75246

4

3/8-16 x 1-1/4" Lg. Self-

Tapping

18

22129

2

WASHER, M8-Lock

19

39253

2

CAPSCREW, M8-1.25 x 16

Hx Hd

20

92557

1

ASSEMBLY, Control Panel

21

96867

1

ASSEMBLY, Stepper Motor

23

18553621 1

ASSEMBLY, Ground Wire

24

86292

5

CAPSCREW, #10, Self Driller

25

23762

1

WASHER, #10 Shakeproof

26

79661N

1

DECAL, Engine

27

B4986

1

DECAL, Ground

28

92982

1

DECAL, Danger

29

92563

1

DECAL, Control Panel

Item Part #

Qty Description

30

93016

1

DECAL, Side Panel

31

NSP

1

DECAL, Data Plate

32

77816

1

DECAL, Caution Hot Muffler

33

95349

1

PLATE, Adjusting

34

95348

1

BELL CRANK

37

93826

1

DECAL, Start Instructions

38

75477

2

SCRW, M5-0.8 x 20 Phillips

Hd

39

96716

3

WASHER, Nylon 

40

95921

1

LINKAGE, Bell Crank to

Throttle

41

95920

1

LINKAGE, Stepper Motor to

Bell Crank

42

33141

1

CAPSCRW,10-32 x 3/4" Hex

Hd

43

51713

1

WASHER, M5 Flat

44

49226

1

WASHER, M5 Lock

45

62265

2

GROMMET, Rubber

47

22261

1

WASHER, 3/8 Internal

Shakeproof

49

96378

1

SPACER

50

96717

1

SPRING

51

81886

1

DECAL, STA-BIL

52

73054

1

DECAL, Fuel Shut Off

Items Not Shown

B4428

1

Generator Owner’s Manual

37806

1

125V 30A Plug

43438

1

120/240V 30A Plug

65787

1

Battery Charge Cable

93568

1

125V 30A Plug

GENERATOR PARTS LIST

Содержание MC10000

Страница 1: ...will eliminate the danger Always have at least two feet of clearance on all sides of the generator even while operating the unit outdoors DANGER You must isolate the generator from the electric utilit...

Страница 2: ...ected electrical loads Operating at excessively low speeds imposes a heavy load and when adequate engine power is not available may shorten engine life SAFETY RULES This generator set was designed and...

Страница 3: ...e unit might be obstructed Allow at least 2 feet of clearance on all sides of unit or you damage could result Never start or stop the unit with electrical loads connected to receptacles AND with the c...

Страница 4: ...50 Amp Receptacle May be used to supply electrical power for the operation of 120 240 Volt AC 50 Amp single phase 60 Hz electrical loads Air Cleaner Used to limit the amount of dirt and dust that get...

Страница 5: ...cable Oil fill spout Spark arrestor screen BEFORE STARTING THE ENGINE Add Engine Oil NOTE When adding oil to the engine crankcase in the future use only high quality detergent oil rated with API serv...

Страница 6: ...n page 12 Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur OPERATING THE GENERATOR CAUTION Never start or stop the unit with electrical loads connected to...

Страница 7: ...rks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely caustic sulfuric acid so...

Страница 8: ...up to 2400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volts at 20 Amps or greater 120 Volt AC 20 Amp Locking Receptacle Use a NEMA L5 20 plug with this receptacle Connect...

Страница 9: ...circuit breaker 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volts AC at 30 Amps or greater Figure 7 You can use the sa...

Страница 10: ...y still feel a shock but the GFCI should cut current off quickly enough so that a person in normal health should not suffer any serious electrical injury DANGER The GFCI will not protect you against t...

Страница 11: ...you to determine how many items the generator can operate at one time Device Running Watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charg...

Страница 12: ...ation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings To Clean the Generator Use a damp cloth or a soft bristle brush to...

Страница 13: ...aner 2 Clean or replace air cleaner 3 Out of gasoline 3 Fill fuel tank 4 Stale gasoline 4 Drain gas tank fill with fresh fuel 5 Spark plug wire not connected 5 Connect wire to spark plug to spark plug...

Страница 14: ...Generac Portable Products MC10000 Extended Life Generator 14 SCHEMATIC...

Страница 15: ...Generac Portable Products MC10000 Extended Life Generator 15 WIRING DIAGRAM...

Страница 16: ...Generac Portable Products MC10000 Extended Life Generator 16 GENERATOR EXPLODED VIEW...

Страница 17: ...Wire 24 86292 5 CAPSCREW 10 Self Driller 25 23762 1 WASHER 10 Shakeproof 26 79661N 1 DECAL Engine 27 B4986 1 DECAL Ground 28 92982 1 DECAL Danger 29 92563 1 DECAL Control Panel Item Part Qty Descript...

Страница 18: ...7 B55275 3 GUARD Fan 8 BB2700 1 CASTING Adapter 9 24114 4 NUT 5 16 24 Hex 10 22237 4 WASHER 3 8 Lock Item Part Qty Description 11 23152 4 CAPSCREW 3 8 16 x 3 4 Hex Head 12 92381 1 ASSEMBLY Rotor 10 KW...

Страница 19: ...f 18 66822 1 12V DC Outlet Bracket 19 43182 4 M3 Lock Washer 20 75207A 2 30A Circuit Breaker 21 78653 1 RUN STOP Switch Item Part Qty Description 22 93986 4 M3 0 5x20mm Mach Screw 23 91526 4 M5 0 8 x...

Страница 20: ...enerator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or sto...

Отзывы: