Operation
28
Owner’s Manual for MLT6SMDS - MLT6SKDS Light Tower
is extending at the top sections of the mast. Stop
extending the mast when the colored mark (C) on
the second mast section is visible as seen in Detail
C.
IMPORTANT NOTE: A limit switch on the main mast
section will disconnect power to the electric winch to
prevent overextending the mast.
IMPORTANT NOTE: Contact a GMP ASD immedi-
ately if the mast hangs up or the winch cable devel-
ops slack.
Raising the Mast—Power Zone-
DLA (If Equipped)
NOTE:
Units with the Power Zone-DLA do not have a
mast switch for the electric winch.
1.
Set up and level the unit. See
2.
Turn the control power switch to on.
3.
See
and
. Press the up/down
arrows (A) until the mast screen is shown.
Figure 3-4. Power Zone Controller
Figure 3-5. Raising the Mast Screen
4.
Press the SELECT button (B); the UP/DOWN on
the display will begin to flash. Press the arrows as
needed until the mast is at the desired height. See
. Do not extend past the colored mark
(C).
5.
Press SELECT again to exit the mast control
screen.
IMPORTANT NOTE: Contact a GMP ASD immedi-
ately if the mast hangs up or the winch cable devel-
ops slack.
DANGER
Electrocution. DO NOT use the unit if
electrical cord is cut or worn through. Doing
so will result in death or serious injury.
(000263a)
WARNING
(000266)
Tipping hazard. Extend the outriggers and level the unit
before raising the mast. Keep the outriggers extended while
the mast is up. Failure to do so could cause the unit to tip
and fall and could result in death or serious injury.
WARNING
Tipping hazard. Do not extend the mast beyond the
colored mark on the second mast section. The unit
can become unstable and tip or fall, causing injury.
(000262)
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
(000279)
Personal injury or equipment damage. Do not raise
or lower the mast while the unit is operating.
Doing so can break the lenses and cause the
lamps to shatter.
WARNING
Select
002353
A
B
Содержание MAGNUM MLT6SKDS
Страница 46: ...Maintenance 42 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 52: ...Wiring Diagrams 48 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower AC Wiring Diagram MLT6SKDS With Power Zone...
Страница 65: ...Service Log Owner s Manual for MLT6SMDS MLT6SKDS Light Tower 61 This page intentionally left blank...
Страница 66: ...Service Log 62 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 67: ......