Operation
Owner’s Manual for MLT Light Tower
17
The most recent alarm or code is the first to be
listed, with the time/date of the alarm or code at the
bottom of the screen. The controller stores up to
117 codes. When full, the controller will
automatically remove the oldest file. These codes
will not be lost when the control power switch is
powered off.
Figure 3-8. History Screen
NOTE:
To view the display screen longer, push the
PAGE SELECT until you reach the Ready screen. Then
press the
or
buttons to navigate to the screens you
want. The screens will display for approximately 45
seconds.
MDC Fault Reset
When a fault condition occurs, the engine will shut down
automatically and the screen will show the fault that has
caused the shutdown. To resume operation, the fault
condition must be resolved. To reset the controller and
resume operation, press FAULT RESET button.
MDC Operational Status
MDC Alarm Management
No. Engine State
Description
1
AfterCool
Engine aftercooling, cooling pump
output is closed.
2
Cooling
The unit is cooling before stop.
3
Cranking
Engine is cranking.
4
EmergMan
Emergency manual gen-set opera-
tion.
5
Init
Autotest during controller power on.
6
Loaded
The unit is running at nominal speed
and GCB OPEN/CLOSE is closed.
7
Not Ready
The unit is not ready to start.
8
Pause
Pause between start attempts.
004528
9
Prestart
Prestart sequence in process, pre-
start output is closed.
10
Ready
The unit is ready to run.
11
Running
The unit is running at nominal
speed.
12
Shutdown
Shutdown alarm is activated.
13
Starting
Starting speed is reached and the
idle timer
is running.
14
Stop
Stop.
No. Electrical State
Description
1
StabilTO
Stabilization timeout.
No.
Type
Description
1
Sensor fail
(FLS)
Sensor fail is detected when mea-
sured value is 6% out of the selected
characteristic. Sensor fail is indicated
by ##### symbol instead of measured
value.
2
Warning
(WRN)
When warning comes up, refer to list
of alarms.
3
Shutdown
(SD)
When the shutdown alarm comes up,
the digital controller opens outputs
GCB CLOSE/OPEN, FUEL, SOLE-
NOID, STARTER and PRESTART to
stop the engine immediately.
No. Engine State
Description