background image

Owner’s Manual for DF7500 Dust Suppression System

19

Operation

Automatic Oscillation

NOTE: 

Transport  locks  must  be  disengaged  before

using oscillation system. See 

Using Transport Locks

.

See 

Figure 3-7

.  When  the  oscillation  system  is  set  to

ON,  blower  rotation  is  controlled  by  the  placement  of
limiting  pins  (A).  Oscillation  range  can  be  adjusted  by
moving  limiting  pins  to  any  hole  (B)  in  the  deck.  When
micro  switch  (C)  contacts  a  limiting  pin  the  blower
reverses direction.

Figure 3-7. Automatic Oscillation

1. Turn OFF oscillation system. See 

Control Panel

.

2. Manually  rotate  blower  to  the  extreme  the  blower

should rotate to the left.

3. Install  limiting  pin  (B)  into  nearest  hole  (B)  to  the

left of micro switch (C).

4. Manually  rotate  blower  to  the  extreme  the  blower

should rotate to the right.

5. Install  limiting  pin  (B)  into  nearest  hole  (B)  to  the

right of micro switch (C).

6. Turn ON oscillation system. See 

Control Panel

.

NOTE: 

When  shutting  down  the  unit,  switch  off

automatic  oscillation  first.  See 

Stopping the Unit

  for

proper shutdown sequence.

Using the Transmitter

The operator using the radio control system must:

Understand transmitter and machine functions.

Visually  follow  machine  movements  activated  by
transmitter.

Switch  off  transmitting  unit  whenever  suspending
the job. 

Remember  the  transmitter  can  activate  machine
movements even in indoor locations away from the
receiving unit.

Never leave the transmitter unattended.

Avoid using radio control inside shielded areas.

Replace batteries when discharged.

NOTE: 

If  radio  control  fails  at  any  time,  switch  control

switch (A) to MANUAL CONTROL.

1. See 

Figure 3-8

Move control switch (A) to RADIO

CONTROL.

2. Verify  emergency  switch  (B)  is  in  the  out,  armed

position.  If  emergency  switch  is  not  armed,  twist
counterclockwise to reset.

 

Figure 3-8. Control Panel

3. See 

Figure 3-9

. Switch main on-off switch (A) on

back of transmitter to ON.

Figure 3-9. Transmitter

4. Select fan on/off (B), pump on/off (C), oscillation on/

off (D), tilting up/down (E), or fan and pump on (F). 

NOTE: 

If LED (G) does not flash or flashes weakly when

a button is pressed, the battery needs to be replaced.

NOTE: 

Pushing  the  stop  button  on  the  control  panel

immediately disables all radio control.

5. Use  macro  button  (G)  to  automatically  switch  off

oscillation, pump, and fan in the proper shutdown
sequence.

008805

C

A

B

008780

B

A

G

A

009034

B

C

D

E

F

G

Содержание DF7500

Страница 1: ...NCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For DF7500 Dust Suppression System 009111 For technical assistance contact www generacmobileproducts co...

Страница 2: ...ance Proper maintenance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to ver...

Страница 3: ...ol Panel Components and Functions 10 Unit and Serial Number Locations 10 Connecting Water Supply 11 Connecting Power Supply 11 Using Transport Locks 12 Disengaging Transport Locks 12 Engaging Transpor...

Страница 4: ...2 Owner s Manual for DF7500 Dust Suppression System This page intentionally left blank...

Страница 5: ...dealer go to https www gener acmobileproducts com parts service find service When contacting an ASD about parts and service always supply the complete model and serial number of the unit as given on t...

Страница 6: ...maintain this equipment Failure to follow proper installation requirements could result in death serious injury and equipment or property damage CAUTION 000229 Equipment or property damage Do not blo...

Страница 7: ...rd people or animals Shut unit OFF immediately if people or animals enter the work area Failure to do so could result in death or serious injury DANGER Electrocution DO NOT use the unit if electrical...

Страница 8: ...ay from heavy traffic prior to transporting the unit Maximum recommended speed for highway towing is 45 mph 72 km h Recommended off road tow ing speed is 10 mph 16 km h or less depending on terrain Wh...

Страница 9: ...igure 1 1 Safety Decal Locations IMPORTANT NOTE See original trailer operating manual for trailer safety and operating decal information Table 1 1 Decal Descriptions ID Description 1 Electric Shock Ha...

Страница 10: ...6 Owner s Manual for DF 7500 Dust Suppression System Introduction and Safety This page intentionally left blank...

Страница 11: ...et Water Filter micron mesh 180 80 Number of Nozzles 24 Rotation Angle Range degrees 335 Tilt Angle degrees 0 40 Noise Level DB 22 ft 7 m 84 Maximum Horizontal Range without wind ft m 98 131 30 40 Max...

Страница 12: ...t Safety Locks E Control Panel J Electrical Socket 009032 A A B A C D E F G H I J G F E D C B A H J K L N M I Control Panel Components and Functions A Manual Control Switch B Oscillation System Switch...

Страница 13: ...requirements will void warranty Water supply must meet the following requirements Water must be greater than 15 gallons per minute 52 liters per minutes and no less than 14 psi 1 bar Water supply hose...

Страница 14: ...e to socket D Figure 2 9 Electrical Connection A 009111 000145 DANGER Electrocution In the event of electrical accident immediately shut power OFF Use non conductive implements to free victim from liv...

Страница 15: ...2 Engage transport locks See Using Transport Locks 3 Remain aware of people and objects around the unit while preparing maneuvering and lifting the unit When lifting the unit attach any slings chains...

Страница 16: ...12 Owner s Manual for DF7500 Dust Suppression System General Information This page intentionally left blank...

Страница 17: ...in death or serious injury 000152 DANGER Electrocution Verify electrical system is properly grounded before applying power Failure to do so will result in death or serious injury 000104 DANGER Electro...

Страница 18: ...sing automatic oscillation system must be set up prior to operation See Automatic Oscillation NOTE If the fan does not start and phase controller error lamp G is lit turn phase controller switch H to...

Страница 19: ...using the radio control system must Understand transmitter and machine functions Visually follow machine movements activated by transmitter Switch off transmitting unit whenever suspending the job Re...

Страница 20: ...20 Owner s Manual for DF7500 Dust Suppression System Operation This page intentionally left blank...

Страница 21: ...chance of someone inadvertently trying to start the unit Inspecting the Unit If the unit is stored outside check for water inside the cabinet and control panel cover before each use If wet dry the uni...

Страница 22: ...enance Cleaning Inlet Filter 1 See Figure 4 5 Unscrew and remove water inlet B 2 Remove filter cartridge 3 Tap cartridge on a solid surface and blow with com pressed air to remove sediment 4 Install c...

Страница 23: ...GMP ASD A A B Problem Possible Cause Solution Water Pump Doesn t Work Pump dry Air in water system Insufficient water inlet pressure Open main water tap Open water control valves Verify sufficient wat...

Страница 24: ...24 Owner s Manual for DF7500 Dust Suppression System Maintenance and Troubleshooting This page intentionally left blank...

Страница 25: ...Owner s Manual for DF7500 Dust Suppression System 25 Maintenance and Troubleshooting This page intentionally left blank...

Страница 26: ...26 Owner s Manual for DF7500 Dust Suppression System Maintenance and Troubleshooting This page intentionally left blank...

Страница 27: ......

Страница 28: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Mobile Products LLC Generac Mobile Products LLC 215 Pow...

Отзывы: