background image

Generac Portable Products 7200 Watt Mobile Backup Power System

3

• The generator produces a very powerful voltage that can

cause serious injury or death by electrocution. Never
touch bare wires or receptacles. Never permit a child or
any unqualified person to operate the generator.

• Never handle any kind of electrical cord or device while

standing in water, while barefoot or while hands or feet
are wet. Death or serious injury from electrocution may
result.

• Use a ground fault circuit interrupter (GFCI) in any damp

or highly conductive area (such as metal decking or steel
work).

• Never use worn, bare, frayed or otherwise damaged

electrical cords with the generator. Death, serious injury
and property damage from electrical shock may result.

• Gasoline is highly FLAMMABLE and its vapors are

EXPLOSIVE. Never allow smoking, open flames,
sparks or heat in the vicinity while handling
gasoline. 
Avoid spilling gasoline on a hot engine. Comply
with all laws regulating storage and handling of gasoline.

• Do Not overfill the fuel tank. Always allow room for fuel

expansion. If tank is overfilled, fuel can overflow
onto a hot engine and cause a FIRE or an
EXPLOSION.

• Never store a generator with fuel in the tank where

gasoline vapors might reach an open flame, spark or pilot
light (as on a furnace, water heater, clothes dryer). FIRE
or an EXPLOSION may result.

• The unit requires an adequate flow of cooling air for its

continued proper operation. Never operate the unit
inside any room or enclosure where the free flow of
cooling air into and out of the unit might be obstructed.
Allow at least 2 feet of clearance on all sides of generator,
even while operating unit outdoors, or you could damage
the unit.

• Never start, or stop the unit with electrical loads

connected to receptacles with the connected devices
turned ON. Start the engine and let it stabilize before
connecting any electrical loads. Disconnect all electrical
loads before shutting down the generator.

• Do Not insert any object through cooling slots of the

engine.You could damage the unit or injure yourself.

• Never operate the generator:

in rain; in any enclosed compartment; when connected
electrical devices overheat; if electrical output is lost; if
engine or generator sparks; if flame or smoke is observed
while unit is running; if unit vibrates excessively.

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure 1).

Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing nut
and to an earth–driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.

Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.

Figure 1 — Grounding Wing Nut

Grounding Wing  Nut

Содержание 1277-0

Страница 1: ...safety messages that follow this symbol to avoid possible injury or death Model No 1277 0 7 200 Watt Mobile Backup Power System Manual No B4678 Revision 2 06 20 2001 Visit our Generac website www gene...

Страница 2: ...erator is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured f...

Страница 3: ...of clearance on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected d...

Страница 4: ...rton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The Generator Power...

Страница 5: ...and the tires are at the proper inflation The operating range should be 15 40 PSI INSTALLING TRAY AND BATTERY NOTE The generator can be started manually If you choose not to use the electric start fea...

Страница 6: ...hot Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the generator engine Do...

Страница 7: ...foam precleaner to limit the amount of dirt and dust that gets in the engine Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a circuit breaker to prot...

Страница 8: ...ull slowly until slight resistance is felt Then pull rapidly one time only to start engine If engine starts proceed to step 7 If engine fails to start proceed to step 6 6 Move the choke lever to Half...

Страница 9: ...dew point your generator may experience icing of the carburetor and or the crankcase breather system In an emergency use the original shipping box as a temporary shelter Cut off all flaps Cut out one...

Страница 10: ...olts 7200 watts of power 7 2 kW at 30 Amps for 240 Volts The outlet is protected by a 30 Amp push to reset circuit breaker Use this plug to connect the unit to the Power Transfer System as described i...

Страница 11: ...general reference Some electric motors such as induction types require about three times more watts of power for starting than for running This surge of power lasts for only a few seconds when startin...

Страница 12: ...through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually de...

Страница 13: ...6 Bad spark plug 7 Water in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to Run 2 Clean or...

Страница 14: ...Generac Portable Products 7200 Watt Mobile Backup Power System 14 SCHEMATIC...

Страница 15: ...Generac Portable Products 7200 Watt Mobile Backup Power System 15 WIRING DIAGRAM...

Страница 16: ...Generac Portable Products 7200 Watt Mobile Backup Power System 16 EXPLODED VIEW MAIN UNIT...

Страница 17: ...6292 1 HHCS 10 Self Driller 38 77395 4 NUT Flange Lock M6 39 83465 4 GROMMET Tank 40 78831B 4 HHMS M6 1 0 x 60 SEMS 41 80270 1 VALVE Tank 42 78299 1 BUSHING Plastic Tank 43 B4363 1 CAP Fuel Gauge Item...

Страница 18: ...50 5 HB4122 1 ASSEMBLY Handle Hitch 6 HB3375 1 WELDMENT Fork Pivot 7 HB4115 1 ASSEMBLY Pivot 8 B4134 1 GRIP Handle 9 B4135 1 PIN Handle Release Item Part Qty Description 10 89635 2 SPACER Wheel 11 222...

Страница 19: ...BREAKER 30A Manual 2 Pole 13 23365 6 WASHER 8 Shakeproof 14 43437 1 OUTLET 120 240V 30A 15 43180 6 FLAT WASHER M4 16 22264 6 LOCK WASHER M4 Item Part Qty Description 17 51715 6 NUT M4 0 7 Hex 18 68759...

Страница 20: ...al maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloa...