Generac Portable Products 7200 Watt Mobile Backup Power System
7
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp
Receptacles
120/240 Volt AC, 30 Amp
Receptacle
Light
Air Cleaner
Spark Arrester
Muffler
Hour Meter
Fuel Tank
Light Switch
DC Float
Charger Jack
Circuit
Breakers
Run–Stop Switch
Choke Lever
Engine Start Switch
120 Volt AC, 20 Amp Receptacles — May be used to
supply electrical power for the operation of 120 Volt AC,
20 Amp, single phase, 60 Hz electrical lighting, appliance,
tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
Air Cleaner — Uses a dry type filter element and foam
precleaner to limit the amount of dirt and dust that gets in
the engine.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Each receptacle is provided
with a circuit breaker to protect the generator against
electrical overload. Breakers are "push to reset" type.
DC Float Charger Jack — Plug the battery float charger
into this jack and into a building wall outlet to provide a
trickle charge during storage.
Engine Start Switch - Press to start the engine.
Fuel Tank — Capacity of eight (8) U.S. gallons.
Grounding Wing Nut — (Not shown, see page 3) Used
for proper grounding of unit.
Hour Meter — The hour meter records the total number
of hours the generator has been running and is used to
schedule maintenance tasks.
Light, Light Switch — The light provides light during a
power outage so that the generator can be connected to
the Power Transfer System safely.The light is turned on and
off with the Light Switch.
Recoil Starter — (Not shown) Used as backup method
of starting the engine.
Run/Stop Switch — Set this switch to "RUN" before
starting. Set switch to "STOP" to turn off engine.
Spark Arrestor Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrestor screen.
Содержание 1277-0
Страница 14: ...Generac Portable Products 7200 Watt Mobile Backup Power System 14 SCHEMATIC...
Страница 15: ...Generac Portable Products 7200 Watt Mobile Backup Power System 15 WIRING DIAGRAM...
Страница 16: ...Generac Portable Products 7200 Watt Mobile Backup Power System 16 EXPLODED VIEW MAIN UNIT...