Section 5: Drawings and Diagrams
16
Homelink Upgradeable Manual Transfer Switch Owner’s Manual
This page intentionally left blank.
Страница 1: ...rvice support product support lookup Pour le fran ais visiter http www generac com service support product support lookup Register your Generac product at WWW GENERAC COM 1 888 GENERAC 888 436 3722 MO...
Страница 2: ...product contains or emits chemicals known to the state of California to cause cancer birth defects and other reproductive harm 000004 WARNING California Proposition 65 Engine exhaust and some of its...
Страница 3: ...ng Branch Circuit Conductors Canadian Installations 7 Installing Breakers 7 Breakers Listed for Use 7 Portable Generator Grounding Requirements 7 Automatic Upgrade Kit Installation 7 Section 4 Operati...
Страница 4: ...iv Homelink Upgradeable Manual Transfer Switch Owner s Manual This page intentionally left blank...
Страница 5: ...MODIFY THIS MANUAL AT ANY TIME Safety Rules The manufacturer cannot anticipate every possible circumstance that might involve a hazard The warnings in this manual and on tags and decals affixed to the...
Страница 6: ...death serious injury and equipment damage 000195 DANGER Electrocution equipment and property damage Handle transfer switches carefully when installing Never install a damaged transfer switch Doing so...
Страница 7: ...heating equipment where the sum of motor full load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent...
Страница 8: ...e the following NFPA 70 National Electrical Code UL 1008 STANDARD FOR SAFETY AUTOMATIC TRANSFER SWITCHES UL67 Panel boards NOTE To ensure code compliance it is essential to use the latest version of a...
Страница 9: ...to the bottom plate For installations where side clearance exceeds 12 inches on both sides remove the screw that secures the bottom plate to the box For wiring entry into the back of the PIB install...
Страница 10: ...ct which branch circuits will be protected by the generator in the normal power panel board 2 Turn the circuit breaker in the normal power panel board to the off position 3 Remove the ungrounded hot c...
Страница 11: ...tion requirements for the wiring method s selected NOTE The two foot pre wire whip can be shortened if needed or removed and replaced with field wiring The factory installed branch circuits and circui...
Страница 12: ...er onto the neutral terminal bar in the transfer switch E in Figure 3 5 10 Terminate the normal power feeder conductors to N1 and N2 on the transfer mechanism F in Figure 3 5 11 Terminate the panelboa...
Страница 13: ...roceeding verify the position of the switch by observing the position of manual operation handle in Figure 4 1 If the handle is DOWN the contacts are closed in the NORMAL UTILITY position no further a...
Страница 14: ...The generator now powers all LOAD circuits Check generator operation under load as follows Turn on electrical loads to the full rated wattage amperage capacity of the generator DO NOT OVERLOAD With m...
Страница 15: ...r Light on the transfer switch will turn off 15 Disconnect the generator portable power cord 16 Store the generator as suggested by the manufacturer 17 Transfer switch testing is complete and ready fo...
Страница 16: ...f turning the unit off for longer than 24 hours remove the F1 fuse from the generator controller To turn the generator ON 1 Reinstall F1 fuse if necessary 2 Put the generator back into AUTO and allow...
Страница 17: ...3 Section 5 Drawings and Diagrams Installation Drawing No 0K8843 A 7 08mm 0 3 4 42mm 0 2 R4mm R0 2 R7mm R0 3 KNOCKOUT SUITABLE FOR 3 4 1 CONDUIT SIZE IF 2 FT WHIP NOT INCLUDED 292mm 11 5 279mm 11 0 37...
Страница 18: ...ion Drawing No 0K8845 A Manual Transfer Connections 100A OR 200A SERVICE HOUSE MAIN CIRCUIT BREAKER 50A 2 POLE 8 CIRCUIT TRANSFER SWITCH NEUT N2 N1 E1 E2 GND GND NEUT POWER INLET BOX NOTE WHEN UTILIZE...
Страница 19: ...r s Manual 15 Interconnection Drawing No 0K8844 C Automatic Transfer Connections 100A OR 200A SERVICE HOUSE MAIN CIRCUIT BREAKER 50A 2 POLE T1 N2 N1 23 194 E2 E1 GND T1 N2 N1 23 194 E2 E1 N1 N2 GENERA...
Страница 20: ...Section 5 Drawings and Diagrams 16 Homelink Upgradeable Manual Transfer Switch Owner s Manual This page intentionally left blank...
Страница 21: ......
Страница 22: ...c All rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45...