FIRE HAZARDS

•  Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. 

Never  permit  smoking,  open  flames,  sparks  or  heat  in  the 
vicinity while handling gasoline. 

•  Never  add  fuel  while  unit  is  running  or  hot. Allow  engine  to  cool 

completely before adding fuel.

•  Never  fill  fuel  tank  indoors. 

Comply  with  all  laws  regulating 

storage and handling of gasoline.

•  Do  not  overfill  the  fuel  tank.  Always  allow  room  for  fuel 

expansion. 

If  tank  is  over-filled,  fuel  can  overflow  onto  a  hot 

engine and cause FIRE or an EXPLOSION. Never store generator 
with fuel in tank where gasoline vapors might reach an open flame, 
spark or pilot light (as on a furnace, water heater or clothes dryer). 
FIRE or EXPLOSION may result. Allow unit to cool entirely before 
storage.

•  Wipe  up  any  fuel  or  oil  spills  immediately.  Ensure  that  no 

combustible materials are left on or near the generator. Keep the 
area  surrounding  the  generator  clean  and  free  from  debris  and 
keep  a  clearance  of  five  (5)  feet  on  all  side  to  allow  for  proper 
ventilation of the generator.

•  Do not insert objects through unit’s cooling slots.

•  Never

  operate  the  generator  if  connected  electrical  devices 

overheat, if electrical output is lost, if engine or generator sparks or 
if flames or smoke are observed while unit is running.

•  Keep a fire extinguisher near the generator at all times. 

STANDARDS INDEX

1.  National Fire Protection Association (NFPA) 70: The NATIONAL 

ELECTRIC CODE (NEC) available from www.nfpa.org

2.  National  Fire  Protection  Association  (NFPA)  5000:  BUILDING 

CONSTRUCTION  AND  SAFETY  CODE  available  from  www.
nfpa.org

3.  International Building Code available from www.iccsafe.org
4.  Agricultural  Wiring  Handbook  available  from  www.rerc.org  , 

Rural Electricity Resource Council P.O. Box 309 Wilmington, OH 
45177-0309

5.  ASAE  EP-364.2  Installation  and  Maintenance  of  Farm  Standby 

Electric Power available from www.asabe.org, American Society 
of  Agricultural  &  Biological  Engineers  2950  Niles  Road,  St. 
Joseph, MI 49085

This  list  is  not  all  inclusive.  Check  with  the  Authority  Having  Local 
Jurisdiction  (AHJ)  for  any  local  codes  or  standards  which  may  be 
applicable to your jurisdiction. 

MODEL NO:

SERIAL NO:

Unit ID Location

MODEL

DATA

DECAL

Safety Rules

 

 

3

Содержание 0065141C

Страница 1: ...r www generac com or 1 888 436 3722 DEADLY EXHAUST FUMES ONLY use OUTSIDE far away from windows doors and vents NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS SAVE this Manual Provide this...

Страница 2: ...nits Only 11 Maintenance 11 3 1 Performing Scheduled Maintenance 11 3 2 Maintenance Schedule 11 3 3 Product Specifications 11 3 4 General Recommendations 12 3 5 Service Air Filter 13 3 6 Valve Clearan...

Страница 3: ...g technique that the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the generat...

Страница 4: ...tical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator...

Страница 5: ...ntilation of the generator Do not insert objects through unit s cooling slots Never operate the generator if connected electrical devices overheat if electrical output is lost if engine or generator s...

Страница 6: ...Refer to Figure 1 and install the Frame Foot and Rubber Bumpers as shown Slide the Rubber Bumper studs through the Frame Foot then install the Locking Flange Nuts Slide the Hex Head Bolts through the...

Страница 7: ...Amp single phase 60 Hz electrical lighting appliance tool and motor loads 3 Circuit Breakers AC Each receptacle is provided with a push to reset circuit breaker to protect the generator against elect...

Страница 8: ...off when the engine is running This signifies that the meter is tracking hours of operation 2 3 CONNECTION PLUGS 2 3 1 120 VAC 20 AMP GFCI DUPLEX RECEPTACLE This is a 120 Volt outlet protected agains...

Страница 9: ...n of the generator The generator MUST be operated outdoors This exhaust system must be properly maintained Do nothing that might render the exhaust system unsafe or in noncompliance with any local cod...

Страница 10: ...rt the largest motor 2 Add to that figure the running watts of all other connected loads The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at on...

Страница 11: ...g open flames sparks or heat in the vicinity while handling gasoline 1 Use regular UNLEADED gasoline with the generator engine Do not use any gasoline with more than 10 added ethanol Do not use E85 ga...

Страница 12: ...in to the Run position If engine falters move choke knob back out to 1 2 Choke position until the engine runs smoothly and then to Run position 2 9 1 MANUAL START This generator is also equipped with...

Страница 13: ...er input is protected by a 1 5 Amp replaceable in line fuse Figure 12 Battery Charger Jack BATTERY CHARGER INPUT 3 1 PERFORMING SCHEDULED MAINTENANCE It is important to perform service as specified in...

Страница 14: ...on the generator internal windings will eventually decrease the insulation resistance of these windings 3 4 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surfaces clean A soft bristle br...

Страница 15: ...before re installing it NOTE To order a new air filter please contact the nearest authorized service center at 1 888 436 3722 Figure 15 Air Filter KNOB TO OPEN AIR BOX 3 6 VALVE CLEARANCE Intake 0 15...

Страница 16: ...e the unit in a clean dry place 3 9 OTHER STORAGE TIPS Do not store gasoline from one season to another Replace the gasoline can if it starts to rust Rust and or dirt in the gasoline will cause proble...

Страница 17: ...Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Turn Fuel Shut off ON 2 Clean or replace air filter 3 Fill fuel tank 4 Drain fuel tan...

Страница 18: ...MENT SERVICE PARTS Description Part No Oil Quart 0G0752 Spark Plug 0G84420101 Air Filter 0G84420151 Fuel Filter 0H1326 Battery 0G9449 Battery Fuse 0K3029 Spark Arrestor 0K3857 Maintenance Kit 005577 0...

Страница 19: ...17 Notes...

Страница 20: ...10 07 14 Printed in U S A 2014 Generac Power Systems Inc All rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from...

Страница 21: ...m o 1 888 436 3722 PELIGRO EMANACIONES DE ESCAPE MORTALES Use NICAMENTE EN EXTERIORES lejos de ventanas puertas y ventilaciones NO EST N DESTINADOS AL USO EN APLICACIONES CR TICAS DE SOPORTE A LA VIDA...

Страница 22: ...uci n del mantenimiento programado 11 3 2 Programa de mantenimiento 11 3 3 Especificaciones del producto 11 3 4 Recomendaciones generales 12 3 5 Servicio del filtro de aire 13 3 6 Luz de v lvulas 13 3...

Страница 23: ...cnica de funcionamiento que el fabricante no recomienda espec ficamente aseg rese de que sea seguro para otras personas Aseg rese tambi n de que el procedimiento m todo de trabajo o t cnica de funcio...

Страница 24: ...ciones suficientes puede causar inconsciencia o incluso la muerte El flujo adecuado y sin obstrucciones de aire de enfriamiento y ventilaci n resulta cr tico para el funcionamiento adecuado del genera...

Страница 25: ...use el generador si los dispositivos el ctricos conectados se recalientan si se pierde la salida el ctrica si el motor o el generador producen chispas o si se observan llamas o humo mientras la unida...

Страница 26: ...lte la Figura 1 e instale el pie del bastidor y los parachoques de caucho como se muestra Deslice los esp rragos de los parachoques de caucho a trav s del pie del bastidor e instale las contratuercas...

Страница 27: ...30 A monof sicos de 60 Hz 3 Disyuntores CA Cada tomacorriente cuenta con un disyuntor de pulsar para reconectar para proteger al generador contra sobrecargas el ctricas 4 Vaciado de aceite Se usa para...

Страница 28: ...llevando un registro de las horas de funcionamiento 2 3 ENCHUFES DE CONEXI N 2 3 1 TOMACORRIENTE DOBLE DE 120 VCA 20 A GFCI Es un tomacorriente de 120 V protegido contra sobrecargas por un disyuntor...

Страница 29: ...er inseguro al sistema de escape o que infrinja cualquier c digo y o norma local Siempre use en interiores una alarma de mon xido de carbono alimentada por bater a instalada conforme a las instruccion...

Страница 30: ...ios de consumo funcionando de todas las otras cargas conectadas La gu a de referencia de potencia en vatios se provee para asistir en la determinaci n de cu ntos elementos puede accionar el generador...

Страница 31: ...que se fume o que haya llamas abiertas chispas o calor en la zona mientras maneje gasolina 1 Use gasolina com n SIN PLOMO en el motor del generador No use ninguna gasolina con m s de 10 de etanol a a...

Страница 32: ...y luego a la posici n de funcionamiento Si el motor falla intermitentemente tire de la perilla del cebador nuevamente a la posici n de medio cebado hasta que el motor funcione suavemente y luego a la...

Страница 33: ...1 5 A sustituible Figura 12 Conector del cargador de bater a BATER A ENTRADA DEL CARGADOR 3 1 EJECUCI N DEL MANTENIMIENTO PROGRAMADO Es importante ejecutar el mantenimiento como se indica en el Progra...

Страница 34: ...el aislamiento de estos devanados 3 4 2 LIMPIEZA DEL GENERADOR Use un pa o h medo para limpiar las superficies exteriores Se puede usar un cepillo de cerdas suave para aflojar tierra compactada aceite...

Страница 35: ...es de volver a instalarla NOTA Para pedir un filtro de aire nuevo comun quese con el centro de servicio autorizado m s cercano llamando al 1 888 436 3722 Figura 15 Filtro de aire PERILLA PARAABRIR LA...

Страница 36: ...cuentren abiertas y sin obstrucciones 8 Almacene la unidad en un lugar limpio y seco 3 9 OTROS CONSEJOS SOBRE EL ALMACENAMIENTO No almacene gasolina de una estaci n a otra Sustituya el contenedor de g...

Страница 37: ...de admisi n se encuentra atorada abierta o cerrada 12 El motor ha perdido compresi n 1 Gire la v lvula de cierre de combustible a la posici n ON 2 Limpie o sustituya el filtro de aire 3 Llene el tanq...

Страница 38: ...cripci n N m de pieza Aceite cuarto de gal 0G0752 Buj a 0G84420101 Filtro de aire 0G84420151 Filtro de combustible 0H1326 Bater a 0G9449 Fusible de bater a 0K3029 Supresor de chispas 0K3857 Kit de man...

Страница 39: ...17 Notas Notas...

Страница 40: ...Impreso en EE UU 2014 Generac Power Systems Inc Todos los derechos reservados Las especificaciones est n sujetas a cambios sin aviso No se permite la reproducci n bajo ninguna forma sin previo consen...

Отзывы: