Section 8 – Warranty

Standby Generator Set

Part No. 0G6781

Revision A (10/03/07)

Printed in U.S.A.

GENERAC POWER SYSTEMS STANDARD TWO-YEAR LIMITED WARRANTY

FOR STANDBY POWER SYSTEMS

NOTE: ALL UNITS MUST HAVE A START-UP INSPECTION PERFORMED BY AN AUTHORIZED GENERAC DEALER.

For a period of two (2) years or two thousand (2,000) hours of operation from the date of sale, which ever occurs first, Generac Power Systems, Inc. 
will, at its option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power Systems or an Authorized/Certified 
Generac Power Systems Dealer, or branch thereof, is found to be defective under normal use and service, in accordance with the warranty schedule 
set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Authorized/Certified Generac Power 
Systems Dealer, or branch thereof. This warranty applies only to Generac Power Systems Generators used in "Standby" applications, as Generac 
Power Systems, Inc. has defined Standby, provided said generator has been initially installed and/or inspected on-site by an Authorized/Certified 
Generac Power Systems Dealer, or branch thereof. Scheduled maintenance, as outlined by the generator owner's manual, must be performed by an 
Authorized/Certified Generac Power Systems Dealer, or branch thereof. This will verify service has been performed on the unit throughout the warranty 
period. This warranty is limited to and available only on Liquid-cooled units.

WARRANTY SCHEDULE

YEAR ONE — One hundred percent (100%) coverage on mileage, labor, and parts listed.
• ALL COMPONENTS — ENGINE, ALTERNATOR, AND TRANSFER SWITCH
YEAR TWO — One hundred percent (100%) coverage on parts listed.
• ALL COMPONENTS — ENGINE, ALTERNATOR, AND TRANSFER SWITCH PARTS ONLY

Gearbox Equipped Units - Limited Gearbox Coverage

YEARS ONE THROUGH FIVE — Parts and labor coverage on gearbox and components.
YEARS SIX THROUGH TEN — Parts only coverage on gearbox and components.

Guidelines:

Travel allowance is limited to 300 miles maximum, and 7.5 hours maximum (per occurrence), round trip, to the nearest authorized Generac Service 
Facility, and only applies to permanently wired and mounted units.
•  Any and all warranty repairs and/or concerns, must be performed and/or addressed by an Authorized/Certified Generac Power Systems Dealer, or 

branch thereof.

•  A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the generator set. If a Non-Generac Power 

Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the generator set, no warranty coverage shall apply.

•  All warranty expense allowances are subject to the conditions defined in Generac Power Systems Warranty, Policies, Procedures and Flat Rate Manual.
• Units that have been resold are not covered under the Generac Power Systems Warranty, as this Warranty is not transferable.
• Unit enclosure is only covered during the first year of the warranty provision.
• Use of Non-Generac replacement part(s) will void the warranty in its entirety.
•  Engine coolant heaters (block-heaters), heater controls and circulating pumps are only covered during the first year of the warranty provision.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

  1.  Any unit built/manufactured prior to July 1, 2004.
  2.  Costs of normal maintenance (i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up).
  3.  Any failure caused by contaminated fuels, oils, coolants/antifreeze or lack of proper fuels, oils or coolants/antifreeze.
 4.  

Units sold, rated or used for "Prime Power", "Trailer Mounted" or "Rental Unit" applications as Generac Power Systems has defined Prime Power, 
Trailer Mounted or Rental Unit. Contact a Generac Power Systems Distributor for Prime Power, Trailer Mounted or Rental Unit definition and 
warranty.

 5.  

Failures caused by any external cause or act of God such as, but not limited to, collision, fire, theft, freezing, vandalism, riot or wars, lightning, 
earthquake, windstorm, hail, volcanic eruption, water or flood, tornado, hurricane, terrorist acts or nuclear holocaust.

  6.  Products that are modified or altered in a manner not authorized by Generac Power Systems in writing.
  7.  Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence, or improper installation or sizing.
 8.  

Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the 
defective part(s).

  9.  Damage related to rodent and/or insect infestation.
 10.  Failure due to misapplication, misrepresentation, or bi-fuel conversion.
 11.  Telephone, facsimile, cellular phone, satellite, Internet, or any other communication expenses.
 12.  Rental equipment used while warranty repairs are being performed (i.e. rental generators, cranes, etc.).
 13.  Overtime, holiday, or emergency labor.
 14.  Modes of transportation deemed abnormal (refer to Generac Power Systems Warranty, Policies, Procedures and Flat Rate Manual).
 15.   Steel enclosures that are rusting due to improper installation, location in a harsh or saltwater environment or scratched where integrity of paint 

applied is compromised.

 16.   Any and all expenses incurred investigating performance complaints unless defective Generac materials and/or workmanship were the direct 

cause of the problem.

 17.  Starting batteries, fuses, light bulbs, engine fluids, and overnight freight cost for replacement part(s).

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, SPECIFICALLY, GENERAC POWER SYSTEMS 
MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limi-
tations on how long an implied warranty lasts, so the above limitation may not apply to purchaser/owner.

GENERAC POWER SYSTEMS ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT 
SHALL GENERAC POWER SYSTEMS BE LIABLE FOR ANY INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A 
DIRECT RESULT OF GENERAC POWER SYSTEMS, INC. NEGLIGENCE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to purchaser/ 
owner. Purchaser/owner agrees to make no claims against Generac Power Systems, Inc. based on negligence. This warranty gives purchaser/owner 
specific legal rights. Purchaser/owner also may have other rights that vary from state to state.

Generac Power Systems, Inc.  •  P.O. Box 8  •  Waukesha, WI 53187

Ph: (262) 544-4811  •  Fax: (262) 544-4851

Bulletin 0166290SBY / Printed in U.S.A.  6.04

Содержание 005366-6

Страница 1: ...Owner s Manual Standby Generator Models 005366 6 005367 6 This manual should remain with the unit www generac com POWER SYSTEMS INC ...

Страница 2: ...ol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment The manufacturer strongly recom mends that the operator read this Owner s Manual and thoroughly understand all instructions before using this equipment The manufacturer also strong ly recommends instructing other users to properly start a...

Страница 3: ... 1 9 2 Battery Chargers 7 Section 2 Installation 7 2 1 STANDBY GENERATOR INSTALLATION 7 2 1 1 NFPA Standards 7 2 1 2 Other Published Standards 8 2 2 BASIC STANDBY ELECTRIC SYSTEM 8 2 3 EMERGENCY CIRCUIT ISOLATION METHOD 8 2 4 TOTAL CIRCUIT ISOLATION METHOD 8 2 5 GROUNDING THE GENERATOR 8 2 6 GENERATOR AC NEUTRAL CONNECTIONS 9 2 7 TRANSFER SWITCH START SIGNAL CONNECTIONS 9 2 8 BATTERY INSTALLATION ...

Страница 4: ...enerator is installed operated and serviced in accordance with the manufacturer s instructions and recommendations Following installation do nothing that might render the unit unsafe or in noncompliance with the aforementioned codes standards laws and regulations The engine exhaust fumes contain carbon monox ide gas which can be DEADLY This dangerous gas if breathed in sufficient concentrations ca...

Страница 5: ... operating Failure to isolate the two electric system power sources from each other by such means will result in damage to the generator and may also result in injury or death to utility power workers due to backfeed of electrical energy Generators installed with an automatic transfer switch will crank and start automatically when normal UTILITY source voltage is removed or is below an acceptable ...

Страница 6: ...e according to NEMA MG1 22 All prototype tested models have passed three phase symmetrical short circuit test to ensure system protection and reliability 1 3 ENGINE PROTECTIVE DEVICES The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera ture oil pressure or rpm For that reason the engine has sever...

Страница 7: ...ications where extremely low ambient temperatures are possible to ensure the temperature of the diesel fuel is not allowed to fall below levels where gell ing could occur 1 6 SPECIFICATIONS 1 6 1 GENERATOR Refer to the data label on the generator for rated watts amperes frequency voltage phase and other pertinent information 1 6 2 ENGINE General Cylinders and Arrangement 5 in line Displacement 3 0...

Страница 8: ...D RECOMMENDATIONS Diesel Fuel System See Chapter 8 of Engine Generator Standby Electric Power Systems Installer s Guide and Reference Manual part 046622 1 7 GENERATOR AC LEAD CONNECTIONS The electrical wires in the unit s AC connection lower panel should be installed according to the number of leads and the voltage phase required for the application If there is any question regarding lead connecti...

Страница 9: ...ury or death to utility workers due to back feed of electrical energy If an open bottom is used the engine generator is to be installed over non combustible materi als and should be located such that combustible materials are not capable of accumulating under the generator set Only qualified competent installation contractors or electricians thoroughly familiar with applicable codes standards and ...

Страница 10: ... overloading the generator by keeping electrical loads below the wattage amperage capac ity of the generator If the generator is powering only critical loads within the wattage amperage capac ity during utility power outages consider using the emergency circuit isolation method Critical electrical loads are grouped together and wired into a separate Emergency Distribution Panel Load circuits power...

Страница 11: ...p in the connection box The conductors for the two wire start circuit must be in their own conduit Figure 2 3 Start Signal Connections 2 8 BATTERY INSTALLATION DANGER Standby generators installed with automatic transfer switches will crank and start automati cally when NORMAL UTILITY source voltage is removed or is below an acceptable preset level To prevent such automatic start up and pos sible i...

Страница 12: ...ting batteries to the generator set NOTE Damage will result if the battery connections are made in reverse 2 9 PREPARATION BEFORE START UP The instructions in this section assume that the standby generator has been properly installed ser viced tested adjusted and otherwise prepared for use by a competent qualified installation contractor Be sure to read the Safety Rules on Pages 2 and 3 as well as...

Страница 13: ...se wires to keep them clear of any moving generator set components 2 9 1 7 Rodent Protection Make sure the four three inch diameter cap plugs part 0A8785 are properly installed in the tie down holes in the side rails of the unit s base frame Figure 2 4 The cap plugs are shipped in a plastic bag located in the lower connection box These plugs are needed to prevent rodents from accessing the interio...

Страница 14: ...eration Drain water from fuel tank Retorque fan bolts Drain and refill gearbox If so equipped The following MUST be performed by an Authorized John Deere Dealer ONLY Check engine valve clearance Test fuel injection nozzles Test injection timing 4 1 2 4 Every Two Years Replace all rubber hoses Replace engine fan belts Inspect the Standby Generator System Drain flush refill cooling system 4 1 2 5 Ev...

Страница 15: ...equipment near the battery Battery electrolyte fluid is an extremely caus tic sulfuric acid solution that can cause severe burns Do not permit fluid to contact eyes skin clothing painted surfaces etc Wear protective goggles protective clothing and gloves when handling a battery If fluid is spilled flush the affected area immediately with clear water Do not dispose of the battery in a fire The batt...

Страница 16: ...rresponds to an identical number on the exploded view drawing 4 3 1 HOW TO ORDER PARTS To order a replacement part locate the part in the applicable exploded view Contact an Authorized Service Dealer call 800 333 1322 to locate one in the area and provide the following information The generator model number The generator identification code which indicates the specific generator assembly for each ...

Страница 17: ... HHC 1 4 20 X 1 2 G5 7 038057 1 GROMMET 7 8 X 1 16 X 3 4 8 0G6794 1 HARN REMOTE ANNUNCIATOR TO GEN 1 9 057593 2 CABLE TIE MOUNT BLACK 1 10 028793A 2 TIE WRAP UL 3 9 X 10 BLK 1 TAPE TIE WRAPS TO INSIDE OF PANEL IF MAIN WIRE HARNESS IS NOT INSTALLED NOTES TERMINAL BLOCK TIGHTENING TORQUE FOR PC BOARDS IS 5 IN LBS Section 5 Exploded Views and Parts Lists Standby Generator Set 20 light Remote Annuncia...

Страница 18: ...3 4 SCREW HHC M8 1 25 X 20 G8 8 8 022129 4 WASHER LOCK M8 5 16 9 022145 8 WASHER FLAT 5 16 ZINC 10 045771 4 NUT HEX M8 1 25 G8 YEL CHR 11 039294 3 CLAMP HOSE 44 2 31 3 25 2 12 061012 1 PLUG STD PIPE 1 8 SOCKET HEAD 1 13 0A4256 1 INDICATOR FILTER MINDER 14 066212 1 CLAMP HOSE 52 2 81 3 75 1 USED WITH VERIZON UNITS 2 USED WITH NON VERIZON UNITS 16 Section 5 Exploded Views and Parts Lists Standby Gen...

Страница 19: ...O 3 COUPLER 7 057646C 1 FLEX EXH 2 5 X 15 44 LONG 8 0E2668 1 ELBOW EXHAUST TURBO OUTLET 9 0E3495 3 SCREW SHC M10 1 25 X 25 G12 9 10 022237 3 WASHER LOCK 3 8 11 026073 1 PLUG STD PIPE 1 8 STEEL SQ HD 12 059557 2 CLAMP AIR CLEANER MOUNT 9 13 069599 2 MUFFLER SUPPORT 12 SUPPLY 3 NPT NIPPLE CUSTOMER TO 8 7 9 10 6 13 4 13 1 11 12 2 4 5 3 17 Section 5 Exploded Views and Parts Lists Standby Generator Set...

Страница 20: ...71 4 NUT HEX M8 1 25 G8 YEL CHR 7 043107 2 SCREW HHC M8 1 25 X 25 G8 8 8 0C7649 2 CLAMP HOSE 38 87 NOT SHOWN 9 035472 2 CLAMP HOSE 6 43 78 10 030340 1 HOSE 1 4 ID SAE 30R7 24 LG 11 055934AA 1 CLAMP VINYL 812 X 531 Z 12 063837 1 SCREW HHC M12 1 75 X 30 G10 9 13 051769 1 WASHER LOCK M12 14 049808 1 WASHER FLAT M12 18 Section 5 Exploded Views and Parts Lists Standby Generator Set Fuel Filter Drawing ...

Страница 21: ... HEX M6 X 1 0 G8 YEL CHR 7 0A4707E 1 ADAPTER 3 8 NPT M18 X 1 5 ITEM PART NO QTY DESCRIPTION 8 0F1449 1 CORE PLUG ADAPT 1 1 4 X 3 8 NPT 9 050967 2 HOSE COOL 5 8 ID 20R3 20 LG 10 0G0015 4 CLAMP HOSE 5 8 DOUBLE WIRE 11 077043A 1 CONDUIT FLEX 38 ID 21 12 0G5212B 2 VALVE 3 8 13 035467 2 NIPPLE CLOSE 3 8 NPT X 1 VIBRA 14 0C4905 2 BARBED EL 45 3 8 NPT X 5 8 OD 19 Section 5 Exploded Views and Parts Lists ...

Страница 22: ... 1 LEVEL 1 GUARD LH 3 0L JD 2 0F1114 1 LEVEL 1 GUARD RH 3 0L JD 3 0F1115 1 LEVEL 1 GUARD BOTTOM 3 0L JD 4 090388 14 SCREW HHTT M6 1 0 X 12 ZINC 20 Section 5 Exploded Views and Parts Lists Standby Generator Set Level One Drawing No 0F1103 A ...

Страница 23: ...SCRIPTION 1 0G36660ST03 2 TOP BOT AIR DUCT 2 0E2671 2 RH LH AIR DUCT RAD 0E1411 3 0C2454 14 SCREW THF M6 1 X 16 N WA Z JS 21 Section 5 Exploded Views and Parts Lists Standby Generator Set Air Duct Kit Drawing No 0G0519 B ...

Страница 24: ...22 22 Section 5 Exploded Views and Parts Lists Standby Generator Set Mounting Base Drawing No 0G3967 A ...

Страница 25: ...CU 24 026850 1 WASHER SHAKEPROOF EXT 1 4 STL 25 022097 1 WASHER LOCK M6 1 4 26 049813 1 NUT HEX M6 1 0 G8 YEL CHR 27 049814 1 SCREW HHC M10 1 5 X 25 G8 8 29 068485 1 SCREW HHC M12 1 25 X 20 G8 8 30 022195 1 WASHER LOCK 1 2 31 049808 1 WASHER FLAT M12 32 070022 3 WASHER LOCK M12 EXT 33 0536210147 1 ASSY WIRE 0 10 0 34 038805J 1 CABLE BATT BLK 1 X 30 00 35 0E2471 1 BATTERY BOX GROUP 27 W COVER 36 0G...

Страница 26: ...24 Section 5 Exploded Views and Parts Lists Standby Generator Set Base Tank Drawing No 0D5400V G ...

Страница 27: ...CREW SHC M8 1 25 X 14 G12 9 IN KIT 0D2734V 14D 097962 4 SCREW SHC M6 1 0 X 25 G12 9 IN KIT 0D2734V 14E 0E4351 1 GASKET ROCHESTER FUEL LEVEL GAUGE 14F 0E4352 1 GASKET ADAPTER PLATE 15 0A1492 1 CAP FUEL FILL 16 0D2670 1 NECK FUEL FILL STANDARD 4 17 063831 1 PLUG STD PIPE 1 25 NPT STEEL SQ HD 18 021178 1 VENT OEM 2 NPT 19 0A7238 1 NIPPLE PIPE 2 NPT X 3 5 BL IRON 20 072989J 2 3 NPT EMRG PRES VENT 21 0...

Страница 28: ...26 Section 5 Exploded Views and Parts Lists Standby Generator Set Enclosure Drawing No 0F1261 C Part 1 ...

Страница 29: ...M PART NO QTY DESCRIPTION 55 0C3157P 4 INSULATION TOP BOTTOM SIDE BRACE 56 0C3157Q 2 INSULATION SIDE SUPPORT 57 0C3157R 1 INSULATION FRONT BRACE TOP 58 0F1253 A 2 INTAKE OVER HEAD MODULE SIDE 59 0C3157T 2 INSULATION REAR CORNER POSTS 1 60 0F0130F 4 INSULATION OVERHEAD MODULE SIDE 61 078115 131 WASHER SELF LOCKING DOME 62 022127 2 NUT HEX 1 4 20 STEEL 64 0C3393 2 SHOULDER SCREW 65 0C3400 A 1 COVER ...

Страница 30: ...28 Section 5 Exploded Views and Parts Lists Standby Generator Set Enclosure Drawing No 0F1261 C Part 2 ...

Страница 31: ...66 0F1254 A 4 END CAP OVER HEAD MODULE SIDE 68 0C3397 2 FASTENER RATCHET 70 0F0153 A 9 SPLITTER 73 0F0774 A 1 BLOCK OFF OVERHEAD MODULE FRONT 77 0F0775 A 1 BLOCK OFF OVERHEAD MODULE REAR 80 0F1275A 1 INSULATION BLOCKOFF OVERHD FRONT 81 066760 1 STRIP SEALANT 1 8 X 1 578 5 84 0F0130K 1 INSULATION BLOCKOFF OVERHD REAR 85 0F0762 A 2 ANGLE WATER DEFLECTOR 88 0C9724 A R CAULK CLIMACEL CLEAR 89 077992 2...

Страница 32: ...30 Section 5 Exploded Views and Parts Lists Standby Generator Set H panel Drawing No 0G5375D A ...

Страница 33: ...NTEGRATED SW NOT SHOWN ITEM PART NO QTY DESCRIPTION COMPONENTS INCLUDED IN WIRE HARNESS A 0F1263 1 ADPTR RH SIDE WICKMANN 178 6191 B 0F1262 4 HOLDER FUSE WICKMANN 178 6150 C 0F1264 1 ADPTR LH SIDE WICKMANN 178 6192 D 0E9049A 2 ASSY PCB G PANEL RELAY 24VDC E 055911 1 BLOCK TERM 20A 12 X 6 X 1100V COMPONENTS NOT INCLUDED IN 0G4141E OR WIRE HARNESS 50 056739 REF RELAY CONTACTOR 12VDC 51 022287 REF SC...

Страница 34: ...32 Section 5 Exploded Views and Parts Lists Standby Generator Set Alternator Connection Box Drawing No 0G0297 B ...

Страница 35: ...ERFACE 1PH 120 240V 2 24 022129 6 4 WASHER LOCK M8 5 16 ITEM PART NO QTY DESCRIPTION 2 25 022145 12 8 WASHER FLAT 5 16 M8 ZINC 2 26 042907 6 4 SCREW HHC M8 1 25 X 16 G8 8 4 27 0F7185 REF MOUNT GOV CONTROL H 100 28 047411 4 SCREW HHC M6 1 0 X 16 G8 8 29 022097 4 REF WASHER LOCK M6 1 4 30 022473 4 REF WASHER FLAT 1 4 M6 ZINC 31 022127 REF NUT HEX 1 4 20 STEEL 32 022287 REF SCREW HHC 1 4 20 X 3 4 G5 ...

Страница 36: ...34 Section 5 Exploded Views and Parts Lists Standby Generator Set Engine Drawing No 0G0300 A ...

Страница 37: ...5 X 20 G8 8 27 022145 2 WASHER FLAT M8 5 16 ZINC 28 022129 6 WASHER LOCK M8 5 16 ITEM PART NO QTY DESCRIPTION 29 052647 12 SCREW SHC M10 1 5 X 25 G12 9 30 022131 20 WASHER FLAT M10 3 8 ZINC 12 USED TO MOUNT TO STATOR 31 046526 28 WASHER LOCK M10 12 USED TO MOUNT TO STATOR 32 070263 5 SCREW HHC M16 2 0 X 35 G10 9 33 0A1646 5 WASHER FLAT M16 34 070265 5 WASHER LOCK M16 35 052858 1 NUT TOP LOCK FL M8...

Страница 38: ...36 Section 5 Exploded Views and Parts Lists Standby Generator Set Radiator Drawing No 0G3946 C ...

Страница 39: ...D STR MA 3 8 NPT X 1 4 33 0C2267 3 SCREW HHTT M5 0 8 X 12 BP 34 022152 2 WASHER LOCK 10 35 023762 2 WASHER SHAKEPROOF EXT 10 STL 36 030150 REF NIPPLE PIPE 3 8 NPT X 3 37 027738A REF PIPE TEE 3 8 NPT ITEM PART NO QTY DESCRIPTION 38 0E0502 REF TEMPERATURE SENDER DELPHI 40 0F6749 1 ADAPTER 3 8 TO 3 8 BRASS 41 030340 1 HOSE 1 4 ID SAE 30R7 10 LG 42 0F0381 REF KIT STANDARD FAN GUARD A 0E9241 1 FAN GUAR...

Страница 40: ...38 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 1 ...

Страница 41: ...39 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 2 39 ...

Страница 42: ...40 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 3 ...

Страница 43: ...41 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 4 ...

Страница 44: ...42 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 5 ...

Страница 45: ...43 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 6 ...

Страница 46: ...44 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 7 ...

Страница 47: ...45 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 100 Alternator Drawing No 0F8214 B Part 8 ...

Страница 48: ...46 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 200 Alternator Drawing No 0G6978 A Part 1 ...

Страница 49: ...47 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 200 Alternator Drawing No 0G6978 A Part 2 ...

Страница 50: ...48 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 200 Alternator Drawing No 0G6978 A Part 3 ...

Страница 51: ...49 Section 6 Electrical Data Standby Generator Set Wiring Diagram H 200 Alternator Drawing No 0G6978 A Part 4 ...

Страница 52: ...50 Section 6 Electrical Data Standby Generator Set Electrical Schematic H 200 Alternator Drawing No 0G6977 A Part 1 ...

Страница 53: ...51 Section 6 Electrical Data Standby Generator Set Electrical Schematic H 200 Alternator Drawing No 0G6977 A Part 2 ...

Страница 54: ...52 Section 6 Electrical Data Standby Generator Set Electrical Schematic H 200 Alternator Drawing No 0G6977 A Part 3 ...

Страница 55: ...53 Section 6 Electrical Data Standby Generator Set Electrical Schematic H 200 Alternator Drawing No 0G6977 A Part 4 ...

Страница 56: ...54 Section 7 Installation Diagram Standby Generator Set Drawing No 0G6990 A ...

Страница 57: ...55 Section 7 Installation Diagram Standby Generator Set Drawing No 0G6990 A ...

Страница 58: ...sponsibility if your non road diesel engine or a part component thereof has failed due to abuse neglect improper maintenance or unapproved modifications or the use of counterfeit and or grey market parts not made sup plied or approved by Generac Your engine is designed to operate on diesel fuel only Use of any other fuel may result in your engine no longer operating in compliance with federal or C...

Страница 59: ...e first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by Generac according to Subsection 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions rel...

Страница 60: ...r of the warranty provision THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING 1 Any unit built manufactured prior to July 1 2004 2 Costs of normal maintenance i e tune ups associated part s adjustments loose leaking clamps installation and start up 3 Any failure caused by contaminated fuels oils coolants antifreeze or lack of proper fuels oils or coolants antifreeze 4 Units sold rated or used for Pri...

Отзывы: