Introduction and Safety

Owner’s Manual for CTF10 Light Tower

1

Section 1: Introduction and Safety

Introduction

Thank you for purchasing a Generac Mobile Products LLC 
product. This unit has been designed to provide high 
performance, efficient operation, and years of use when 
maintained properly. 

The information in this manual is accurate based on prod-
ucts produced at the time of publication. The manufacturer 
reserves the right to make technical updates, corrections, 
and product revisions at any time without notice.

Read This Manual Thoroughly

(000100a)

WARNING

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product
could result in death or serious injury.

If any section of the manual is not understood, contact your 
nearest Generac Mobile Products Authorized Service 
Dealer, or contact

 

Generac Mobile Products LLC at 1-800-

926-9768, or Generac Mobile Products Technical Service at  
1-800-926-9768 or

 

www.generacmobileproducts.com

with any questions or concerns.

The owner is responsible for proper maintenance and safe 
use of the equipment. Comply with regulations the 
Occupational Safety and Health Administration (OSHA) 
has established, or with equivalent standards. Also, verify 
that the unit is applied, used, and maintained in accordance 
with the manufacturer's instructions and recommendations. 
Do nothing that might alter safe application/usage and 
render the unit in noncompliance with the aforementioned 
codes, standards, laws, and regulations.

Save these instructions for future reference. This manual 
contains important instructions for the unit that should be 
followed during setup, operation and maintenance of the 
unit and battery. ALWAYS supply this manual to any 
individual that will use this machine.

How to Obtain Service

W

hen the unit requires servicing or repairs, contact a 

Generac Mobile Products Authorized Service Dealer (GMP 
ASD) for assistance. Service technicians are factory-trained 
and are capable of handling all service needs. For 
assistance locating a dealer, visit 

www.generacmobileproducts.com/parts-service/find-
service

. When contacting a GMP ASD about parts and 

service, always supply the complete model number and 
serial number of the unit as given on its data decal located 
on the unit. Record the model number and serial numbers 
in the spaces provided on the inside front cover of this 
manual.

Safety Rules

The manufacturer cannot anticipate every possible 
circumstance that might involve a hazard. The warnings in 
this manual, and on tags and decals affixed to the unit are, 
therefore, not all inclusive. If using a procedure, work 
method or operating technique that the manufacturer does 
not specifically recommend, verify that it is safe for others. 
Also make sure the procedure, work method or operating 
technique utilized does not render the equipment unsafe.

Throughout this publication, and on tags and decals affixed 
to the unit, DANGER, WARNING, CAUTION and NOTE 
blocks are used to alert personnel to special instructions 
about a particular operation that may be hazardous if 
performed incorrectly or carelessly. Observe them 
carefully. Their definitions are as follows:

(000001)

DANGER

Indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

(000002)

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.

(000003)

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

NOTE: 

Notes contain additional information important to 

a procedure and will be found within the regular text of 
this manual.

These safety alerts cannot eliminate the hazards that they 
indicate. Common sense and strict compliance with the 
special instructions while performing the action or service 
are essential to preventing accidents.

Содержание CTF10

Страница 1: ... REFERENCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For CTF10 Light Tower 010128 For technical assistance contact www generacmobileproducts com Technical Support 1 800 926 9768 ...

Страница 2: ...nance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to verify that all maintenance for safe operation is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operato...

Страница 3: ...er via Smartphone 13 Programming Timer via Control Panel 14 Setting the Clock 14 Programming the Timer 14 Internal Storage 15 Lifting and Transporting 15 Tying the Unit Down 15 Section 3 Operation Operation Configuration Guidelines 17 Light Tower Setup 17 Prestart Checklist 18 Raising the Mast 19 Turning Unit On 20 Turning Unit Off 20 Lowering the Mast 20 Section 4 Maintenance Daily Walk Around In...

Страница 4: ...iv Owner s Manual for CTF10 Light Tower This page intentionally left blank ...

Страница 5: ... requires servicing or repairs contact a Generac Mobile Products Authorized Service Dealer GMP ASD for assistance Service technicians are factory trained and are capable of handling all service needs For assistance locating a dealer visit www generacmobileproducts com parts service find service When contacting a GMP ASD about parts and service always supply the complete model number and serial num...

Страница 6: ...0231a WARNING 000234a WARNING Crushing hazard Verify unit is properly secured and on level ground An unsecured unit can suddenly roll or move causing death or serious injury CAUTION 000306 Equipment Damage Failure to perform a daily inspection could result in damage to the unit Electrical Hazards 000354 DANGER Electrocution In the event of electrical accident immediately shut power OFF and disconn...

Страница 7: ...ising and lowering the mast ALWAYS lower the mast when not in use The tower extends up to 32 ft 9 9 m Verify the area above trailer is open and clear of overhead wires and obstructions If for any reason any part of the mast hangs up or the winch cable develops slack while raising or lowering the tower STOP immediately Contact a Generac Mobile Products Authorized Service Dealer Service Safety This ...

Страница 8: ...shing or cleaning the unit Decal part numbers can be found in the parts manual atwww generacmobileproducts com ID Description ID Description 1 Forklift Pockets 8 Stopping point to prevent mast rotation 2 Help Tech Heavy Equipment Loss Prevention Technology 9 Generac Mobile Logo 3 Read the Manual 10 Warning Extracted Stabilizers 4 Made in Italy 11 Security pin 5 Lifting Point 12 Always extend the o...

Страница 9: ...10 1 1 6 11 009642 10 9 14 14 14 Introduction and Safety Owner s Manual for CTF10 Light Tower 5 Figure 1 2 Decal Locations 2 of 5 ...

Страница 10: ...1 13 6 5 009643 12 1 14 14 14 Introduction and Safety 6 Owner s Manual for CTF10 Light Tower Figure 1 3 Decal Locations 3 of 5 ...

Страница 11: ...10 6 009643 10 1 1 11 9 14 14 14 Introduction and Safety Owner s Manual for CTF10 Light Tower 7 Figure 1 4 Decal Locations 4 of 5 8 7 009644 7 6 Figure 1 5 Decal Locations 4 of 4 ...

Страница 12: ...Introduction and Safety 8 Owner s Manual for CTF10 Light Tower This page intentionally left blank ...

Страница 13: ...ng Tower Raising Manual Sections 6 Rotation Section degrees 340 Electrical Coiled Cable mm 11G2 5 Maximum Wind Stability mph km h 50 80 Weight Weight lbs kg 865 392 Raising and Lowering Rope Rope Type AZ150 06ACAR Specifications are subject to change without notice Refer to the product specification sheet for complete list Serial Number Locations Refer to Figure 2 1 to locate serial number A and n...

Страница 14: ...CTF10 Light Tower General Information Unit Dimensions 010192 B B A C D D Figure 2 2 A B C D CTF 10 Unit Dimensions Specifications are subject to change without notice 100 in 2 54 m 49 1 in 1 247 m 32 5 ft 9 9 m 99 6 in 2 5 m ...

Страница 15: ...cations A Command panel G Forklift pockets B Inspection door H Extractable stabilizers C Floodlights blocking rotation pin I Lifting hook D Floodlights J Safety pin E Telescopic mast K Floodlights rotation handle F Manual winch L Inspection door NOTE For grounding requirements follow local state or National Electrical Code NEC guidelines ...

Страница 16: ...t breakers Individual circuit breakers for the LED light fixtures F Light sensor intensity setting Sets light sensor lux threshold Used when Off Manual Timer Light Sensor selector is set to Light Sensor See Light Sensor for more information G Digital timer Sets timer schedule Used when Off Manual Timer Light Sensor selector is set to Timer See Timer for more information H Electrical ground connect...

Страница 17: ...g is less than or greater than the lux threshold See Table 1 Light Sensor LED for more information Table 1 Light Sensor LED LED Status Light Sensor Status Slow blinking Off Ambient lux is greater than threshold setting Steady On Ambient lux is less than threshold setting NOTE See Figure 2 6 When using the light sensor setting verify light sensor C is clean and exposed to ambient light 010136 C Fig...

Страница 18: ...d down to scroll through values on a page Move the joystick to the right to advance to the next page Year Day Month Hour Minute Daylight savings ON OFF 4 Move joystick right to advance to PIN OFF 5 Move joystick right to advance to END 6 Press joystick to exit settings menu Programming the Timer 1 See Figure 2 7 Press joystick N to advance to Settings A 2 Press joystick to advance to Program menu ...

Страница 19: ...red 3 Verify outriggers and jacks are fully retracted 4 Close and lock access doors and control panel 5 Figure 2 9 To lift unit use one of the following methods Attach slings chains or hooks directly to central lift point A Verify the LED fixtures will not be damaged when lifting Use a forklift Approach forklift pockets B with care Avoid approaching the unit at an angle as this can permanently dam...

Страница 20: ...16 Owner s Manual for CTF10 Light Tower General Information This page intentionally left blank ...

Страница 21: ...wer is required or a second unit will be connected via the 120 V GFCI receptacle connect the unit to a 120VAC 20A supply using the NEMA L5 20 plug NOTE Shore power cords are not included with this unit and must be supplied by the end user See Table 3 1 for recommended cable size and length Table 3 1 Recommended Shore Power Cable Size and Length Suggested Power Cables and Lengths 100 ft 30 5 m 10 3...

Страница 22: ...solved 000100a WARNING Consult Manual Read and understand manual completely before using product Failure to completely understand manual and product could result in death or serious injury Verify all maintenance procedures are up to date For more information refer to General Maintenance and Winch Use Operation and Maintenance Perform a walk around inspection Refer to Daily Walk Around Inspection V...

Страница 23: ...d may damage mast hardware IMPORTANT NOTE Do not use the mast as a hoist or for any other purpose other than supporting LED fixtures 1 Set up and level the unit See Light Tower Setup 2 Inspect mast cables for excessive wear or damage Verify steel cable is properly centered on each pulley 3 See Figure 3 4 Use winch B to slowly extend the mast making sure the coiled electrical cord is extending at t...

Страница 24: ...ry to leave some lights off if the export current exceeds 10 A Turning Unit Off IMPORTANT NOTE Contact a Generac Mobile Prod ucts Authorized Service Dealer immediately if the mast hangs up or the winch cable develops slack NOTE See Control Panel for the location of controls Check with personnel using lights and auxiliary power supplied by the unit and let them know the power is going to be turned ...

Страница 25: ...rying to start the unit Cleaning the Unit CAUTION 000325a Equipment damage Never spray water to clean unit Do not introduce water into generator widings terminals or fuel system during the cleaning process Doing so will result in equipment damage Always clean the unit after each use to remove dust grease mud or spilled fuel or oil Use soft clean rags to wipe the cabinet exterior and control panel ...

Страница 26: ...chanism Winch Mechanical Brake The mechanical brake generates heat when loads are lowered and the wire cable is powered out Care must be taken to avoid overheating the mechanical brake Whine or chatter associated with a new mechanical brake is normal and typically disappears with use Overheating the mechanical brake may result in permanent damage to or failure of the brake Replace any damaged brak...

Страница 27: ...nction box Pin connector LED driver connectors input output on each driver Mast light circuit breakers 4 Input power selector Switch Main breaker switch Faulty main breaker switch Replace main breaker switch Faulty mast light circuit breaker s Replace mast light circuit breaker s Faulty LED driver Verify driver input voltage from input connector is 120 VAC 10 VAC If output voltage from LED Driver ...

Страница 28: ...24 Owner s Manual for CTF10 Light Tower Troubleshooting This page intentionally left blank ...