Generac Mobile CTF10 Скачать руководство пользователя страница 24

20

Owner’s Manual for CTF10 Light Tower

Operation

5. See 

Figure 3-6

. Insert safety pin (G) into mast hole 

(H) and secure with hairpin (I). 

006035

G

H

010138

I

Figure 3-6. Mast Pin

Turning Unit On

DANGER

Electrocution. DO NOT use the unit if
electrical cord is cut or worn through. Doing
so will result in death or serious injury.

(000263a)

NOTE: 

See 

Control Panel

 for the location of controls 

and power inlets.

1. Verify main circuit breaker and mast light circuit 

breakers are in the OFF position. 

1. If required, connect an earth ground to the electri-

cal ground connection on the control panel. See 

Control Panel

 for more information. 

1. Plug in any equipment or an additional light tower.
2. Press the input selector power switch to select 

either a 15 A or 20 A power source. Switch position 
MUST match the connected input source. See 

Operation Configuration Guidelines

 for more 

information.

3. Connect shore power. See 

Table

 

3-1: 

Recommended Shore Power Cable Size and 
Length

.

4. Turn main circuit breaker switch ON.
5. Select the desired operating mode:

Manual

Timer

Light Sensor

6. Turn each mast light circuit breaker ON.
7. Start auxiliary equipment. 

NOTE: 

It may be necessary to leave some lights off if the 

export current exceeds 10 A.

Turning Unit Off

IMPORTANT NOTE: 

Contact a Generac Mobile Prod-

ucts Authorized Service Dealer immediately if the mast 
hangs up or the winch cable develops slack.

NOTE: 

See 

Control Panel

 for the location of controls.

Check with personnel using lights and auxiliary power 
supplied by the unit and let them know the power is going 
to be turned off. Verify the power shutdown will not create 
hazards by turning off equipment that may be in use 
(lights, tools, etc.).

1. Turn OFF and disconnect any auxiliary equipment.
2. Switch individual mast light breakers OFF.
3. Switch Off/Manual/Timer/Light Sensor selector to 

OFF (O).

4. Switch main circuit breaker to OFF (O) position.
5. Disconnect the shore power cord.

Lowering the Mast

WARNING

Personal Injury. Stop immediately if the mast hangs 
up or the winch cable develops slack. Excess slack 
could cause the mast to collapse, resulting in personal 
injury or equipment damage.

(000265)

1. Shut off lights. See 

Turning Unit Off

.

2. Remove mast safety pin.
3. Lower the mast.
4. Use the winch handle to lower the mast to its 

lowest position. Verify the electrical cord does not 
get caught in, or pinched by,  the mast while it is 
being lowered.

IMPORTANT NOTE: 

Contact a Generac Mobile Prod-

ucts Authorized Dealer immediately if the mast hands up 
or the winch cable develops slack.

Содержание CTF10

Страница 1: ... REFERENCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For CTF10 Light Tower 010128 For technical assistance contact www generacmobileproducts com Technical Support 1 800 926 9768 ...

Страница 2: ...nance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to verify that all maintenance for safe operation is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operato...

Страница 3: ...er via Smartphone 13 Programming Timer via Control Panel 14 Setting the Clock 14 Programming the Timer 14 Internal Storage 15 Lifting and Transporting 15 Tying the Unit Down 15 Section 3 Operation Operation Configuration Guidelines 17 Light Tower Setup 17 Prestart Checklist 18 Raising the Mast 19 Turning Unit On 20 Turning Unit Off 20 Lowering the Mast 20 Section 4 Maintenance Daily Walk Around In...

Страница 4: ...iv Owner s Manual for CTF10 Light Tower This page intentionally left blank ...

Страница 5: ... requires servicing or repairs contact a Generac Mobile Products Authorized Service Dealer GMP ASD for assistance Service technicians are factory trained and are capable of handling all service needs For assistance locating a dealer visit www generacmobileproducts com parts service find service When contacting a GMP ASD about parts and service always supply the complete model number and serial num...

Страница 6: ...0231a WARNING 000234a WARNING Crushing hazard Verify unit is properly secured and on level ground An unsecured unit can suddenly roll or move causing death or serious injury CAUTION 000306 Equipment Damage Failure to perform a daily inspection could result in damage to the unit Electrical Hazards 000354 DANGER Electrocution In the event of electrical accident immediately shut power OFF and disconn...

Страница 7: ...ising and lowering the mast ALWAYS lower the mast when not in use The tower extends up to 32 ft 9 9 m Verify the area above trailer is open and clear of overhead wires and obstructions If for any reason any part of the mast hangs up or the winch cable develops slack while raising or lowering the tower STOP immediately Contact a Generac Mobile Products Authorized Service Dealer Service Safety This ...

Страница 8: ...shing or cleaning the unit Decal part numbers can be found in the parts manual atwww generacmobileproducts com ID Description ID Description 1 Forklift Pockets 8 Stopping point to prevent mast rotation 2 Help Tech Heavy Equipment Loss Prevention Technology 9 Generac Mobile Logo 3 Read the Manual 10 Warning Extracted Stabilizers 4 Made in Italy 11 Security pin 5 Lifting Point 12 Always extend the o...

Страница 9: ...10 1 1 6 11 009642 10 9 14 14 14 Introduction and Safety Owner s Manual for CTF10 Light Tower 5 Figure 1 2 Decal Locations 2 of 5 ...

Страница 10: ...1 13 6 5 009643 12 1 14 14 14 Introduction and Safety 6 Owner s Manual for CTF10 Light Tower Figure 1 3 Decal Locations 3 of 5 ...

Страница 11: ...10 6 009643 10 1 1 11 9 14 14 14 Introduction and Safety Owner s Manual for CTF10 Light Tower 7 Figure 1 4 Decal Locations 4 of 5 8 7 009644 7 6 Figure 1 5 Decal Locations 4 of 4 ...

Страница 12: ...Introduction and Safety 8 Owner s Manual for CTF10 Light Tower This page intentionally left blank ...

Страница 13: ...ng Tower Raising Manual Sections 6 Rotation Section degrees 340 Electrical Coiled Cable mm 11G2 5 Maximum Wind Stability mph km h 50 80 Weight Weight lbs kg 865 392 Raising and Lowering Rope Rope Type AZ150 06ACAR Specifications are subject to change without notice Refer to the product specification sheet for complete list Serial Number Locations Refer to Figure 2 1 to locate serial number A and n...

Страница 14: ...CTF10 Light Tower General Information Unit Dimensions 010192 B B A C D D Figure 2 2 A B C D CTF 10 Unit Dimensions Specifications are subject to change without notice 100 in 2 54 m 49 1 in 1 247 m 32 5 ft 9 9 m 99 6 in 2 5 m ...

Страница 15: ...cations A Command panel G Forklift pockets B Inspection door H Extractable stabilizers C Floodlights blocking rotation pin I Lifting hook D Floodlights J Safety pin E Telescopic mast K Floodlights rotation handle F Manual winch L Inspection door NOTE For grounding requirements follow local state or National Electrical Code NEC guidelines ...

Страница 16: ...t breakers Individual circuit breakers for the LED light fixtures F Light sensor intensity setting Sets light sensor lux threshold Used when Off Manual Timer Light Sensor selector is set to Light Sensor See Light Sensor for more information G Digital timer Sets timer schedule Used when Off Manual Timer Light Sensor selector is set to Timer See Timer for more information H Electrical ground connect...

Страница 17: ...g is less than or greater than the lux threshold See Table 1 Light Sensor LED for more information Table 1 Light Sensor LED LED Status Light Sensor Status Slow blinking Off Ambient lux is greater than threshold setting Steady On Ambient lux is less than threshold setting NOTE See Figure 2 6 When using the light sensor setting verify light sensor C is clean and exposed to ambient light 010136 C Fig...

Страница 18: ...d down to scroll through values on a page Move the joystick to the right to advance to the next page Year Day Month Hour Minute Daylight savings ON OFF 4 Move joystick right to advance to PIN OFF 5 Move joystick right to advance to END 6 Press joystick to exit settings menu Programming the Timer 1 See Figure 2 7 Press joystick N to advance to Settings A 2 Press joystick to advance to Program menu ...

Страница 19: ...red 3 Verify outriggers and jacks are fully retracted 4 Close and lock access doors and control panel 5 Figure 2 9 To lift unit use one of the following methods Attach slings chains or hooks directly to central lift point A Verify the LED fixtures will not be damaged when lifting Use a forklift Approach forklift pockets B with care Avoid approaching the unit at an angle as this can permanently dam...

Страница 20: ...16 Owner s Manual for CTF10 Light Tower General Information This page intentionally left blank ...

Страница 21: ...wer is required or a second unit will be connected via the 120 V GFCI receptacle connect the unit to a 120VAC 20A supply using the NEMA L5 20 plug NOTE Shore power cords are not included with this unit and must be supplied by the end user See Table 3 1 for recommended cable size and length Table 3 1 Recommended Shore Power Cable Size and Length Suggested Power Cables and Lengths 100 ft 30 5 m 10 3...

Страница 22: ...solved 000100a WARNING Consult Manual Read and understand manual completely before using product Failure to completely understand manual and product could result in death or serious injury Verify all maintenance procedures are up to date For more information refer to General Maintenance and Winch Use Operation and Maintenance Perform a walk around inspection Refer to Daily Walk Around Inspection V...

Страница 23: ...d may damage mast hardware IMPORTANT NOTE Do not use the mast as a hoist or for any other purpose other than supporting LED fixtures 1 Set up and level the unit See Light Tower Setup 2 Inspect mast cables for excessive wear or damage Verify steel cable is properly centered on each pulley 3 See Figure 3 4 Use winch B to slowly extend the mast making sure the coiled electrical cord is extending at t...

Страница 24: ...ry to leave some lights off if the export current exceeds 10 A Turning Unit Off IMPORTANT NOTE Contact a Generac Mobile Prod ucts Authorized Service Dealer immediately if the mast hangs up or the winch cable develops slack NOTE See Control Panel for the location of controls Check with personnel using lights and auxiliary power supplied by the unit and let them know the power is going to be turned ...

Страница 25: ...rying to start the unit Cleaning the Unit CAUTION 000325a Equipment damage Never spray water to clean unit Do not introduce water into generator widings terminals or fuel system during the cleaning process Doing so will result in equipment damage Always clean the unit after each use to remove dust grease mud or spilled fuel or oil Use soft clean rags to wipe the cabinet exterior and control panel ...

Страница 26: ...chanism Winch Mechanical Brake The mechanical brake generates heat when loads are lowered and the wire cable is powered out Care must be taken to avoid overheating the mechanical brake Whine or chatter associated with a new mechanical brake is normal and typically disappears with use Overheating the mechanical brake may result in permanent damage to or failure of the brake Replace any damaged brak...

Страница 27: ...nction box Pin connector LED driver connectors input output on each driver Mast light circuit breakers 4 Input power selector Switch Main breaker switch Faulty main breaker switch Replace main breaker switch Faulty mast light circuit breaker s Replace mast light circuit breaker s Faulty LED driver Verify driver input voltage from input connector is 120 VAC 10 VAC If output voltage from LED Driver ...

Страница 28: ...24 Owner s Manual for CTF10 Light Tower Troubleshooting This page intentionally left blank ...

Страница 29: ...Owner s Manual for CTF10 Light Tower 25 Section 6 Wiring Diagrams AC Wiring 6 0 OFF 1 MAN 2 TIMER 3 CREP 1 5 4 ...

Страница 30: ...26 Owner s Manual for CTF10 Light Tower Wiring Diagrams This page intentionally left blank ...

Страница 31: ......

Страница 32: ...ights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Mobile Products LLC Generac Mobile Products LLC 215 Power Drive Berlin WI 54923 GeneracMobileProducts com 800 926 9768 920 361 4442 ...

Отзывы: