APPLICATION MODE OPERATION
Basic Weighing (F1)
Basic weighing mode – available in 17 units of measure. See Weighing Units page 7.
Counting Pieces
(Mode Key - F2)
Scroll to the F2 Mode, Press Enter Key, 0 pcs and SAMPLE 1.0000 will appear on the display. Press F2 Key
10 (blinking) will appear on the display along with SAMPLE QUANTITY. Press Up/Down Arrow Key to scroll
through preset sample quantity sizes (10, 20, 50 &100). There is also a user defined sample size display as
0000. Press Enter Key and use Up/Down and Right/Left Arrow Keys to program a custom sample size number.
Press Enter to accept and return to the main display. Press UNITS/ESC Key to Enter the Counting Pieces
Function. If you would like to use a container for your samples place the container on the weigh pan and
Press T/INSERT Key, NET will appear on the display.
Check Weighing (Mode Key – F3)
Scroll to the F3 Mode, Press Enter Key, MIN 100.000 (minimum weight) will appear on the display. Press
Up/Down Arrow Key to set a minimum weight value. Press Enter Key, MAX 100.000 (maximum weight) will
appear on the display. Press Up/Down Arrow Key to set a maximum weight value. Press Enter to accept and
return to the main display. If you would like to use a container for your sample place the container on the weigh
pan and Press T/INSERT Key, NET will appear on the display. In the Checking Weighing mode MIN will
appear when the sample is under the minimum weight value, MAX will appear when the sample is above the
maximum weight value and OK will appear with the sample is between the minimum and maximum weight
values.
Dosing (Mode Key – F4)
Scroll to the F4 Mode, Press Enter Key followed by the F2 Key, SAMPLE 1000.000 (blinking) will appear on
the display. Press Up/Down and Right/Left Arrow Keys to program the dose weight value. Press Enter Key,
TOLERANCE 000.000 (blinking) will appear on the display. Press Up/Down and Right/Left Arrow Keys to
program the dosing tolerance. Press Enter to accept and return to the main display. If you would like to use a
container for your samples place the container on the weigh pan and Press T/INSERT Key, NET will appear on
the display.
Deviations / % (Mode Key - F5)
Scroll to the F5 Mode, Press Enter Key, 0.0000 % and SAMPLE 1.0000 will appear on the display. Press F2
Key PUT 100 will appear on the display. Place the reference mass on the weigh pan and Press Enter Key.
The reference Sample Weight value will appear on the bottom of the display along with the % Icon.
Solids/Density Determination (Mode Key - F6)
The Density of Solids may be calculated using one of three methods (Products):
In (Distilled) WATER
In ETHANOL (100% Spirits, +/- 0.1% at 20°C)
OTHER (another liquid with a known density)
Press Mode Key and scroll to the F6 Mode, Press Enter Key PRODUCT will appear on the display. Press F2
Key and use Up/Down Arrow Key to scroll between WATER, ETHANOL and OTHER. Press Enter Key and
25.0 TEMP (flashing) will appear of the display. Press Up/Down Arrow Keys to program the appropriate
temperature of the liquid. When selecting the OTHER method you will need to program in the sample
Temperature and Density. Press Enter Key, 0.0000 and LIQUID DENS will appear on the display. Press
Up/Down Arrow Keys to program the know density of the liquid. Press Enter Key to save and exit to the
Density (Solids) Calculation Mode.
Page 8
Содержание GA- 225DC
Страница 26: ...Rev A July 2014 ...