Genelec SAM 8340A Скачать руководство пользователя страница 7

7

Figure 10. The curves above show the horizontal directivity 

characteristics of the 8340A. 

Figure 11. The curves above show the vertical directivity 

characteristics of the 8340A. 

SYSTEM SPECIFICATIONS

8340A

Lower cut-off frequency, –6 dB

< 38 Hz

Upper cut-off frequency, –6 dB

> 22 kHz

Accuracy of frequency response, ± 1.5 dB

45 Hz – 20 kHz

Maximum short term sine wave acoustic output on axis in half space, averaged from  

100 Hz to 3 kHz at 1 m 

≥ 110 dB SPL 

Maximum long term RMS acoustic output in the same conditions with IEC weighted 

noise (limited by driver protection circuit) at 1 m 

100 dB SPL

Maximum peak acoustic output per pair in a listening room with music material at 1 m  

≥ 118 dB

Self generated noise level in free space at 1 m on axis (A-weighted)

≤ 5 dB

Harmonic distortion at 90 dB SPL at 1 m on axis 

Freq:  50…100 Hz 

 

> 100 Hz

< 2 %

< 0.5 %

Drivers

Bass

Treble

All drivers are magnetically shielded

165 mm (6

1

/

2

 in) cone

19 mm (

3

/

4

 in) metal dome 

Weight

8.4 kg (18.5 lb)

Dimensions 

Height 

Width

Depth

Height with Iso-Pod™

 

350 mm (13

13

/

16

 in)

237 mm (9

3

/

8

 in)

223 mm (8

13

/

16

 in)

365 mm (14

3

/

8

 in)

accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference 

by one or more of the following measures: 

•  Reorient or relocate the receiving antenna. 

•  Increase the separation between the equipment and receiver. 

•  Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected. 

•  Consult the dealer or an experienced radio/TV technician for 

help 

•  Modifications not expressly approved by the manufacturer 

could void the user’s authority to operate the equipment 

under FCC rules.

Содержание SAM 8340A

Страница 1: ...8340A Operating Manual ...

Страница 2: ...fers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup and the use of GLM in the GLM System Operating Manual The setup is fast and consists of ...

Страница 3: ...nd 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control The Bass Tilt control switches swiches 3 and 4 offer three at tenuation levels for the bass response below 800 Hz usually necessary when the monitors are placed near room boundaries The ...

Страница 4: ...Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Figu...

Страница 5: ...ubwoofers Genelec recommends using the 7300 series subwoofers For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance There are no user serviceable parts inside the monitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour I...

Страница 6: ...d Genelec service The monitor enclosure must not be opened Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not...

Страница 7: ...l drivers are magnetically shielded 165 mm 61 2 in cone 19 mm 3 4 in metal dome Weight 8 4 kg 18 5 lb Dimensions Height Width Depth Height with Iso Pod 350 mm 1313 16 in 237 mm 93 8 in 223 mm 813 16 in 365 mm 143 8 in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If...

Страница 8: ...gital input sensitivity 100 dB SPL at 1 m Digital input gain sensitivity rotary control AES EBU Single Wire AES EBU Single Wire 16 24 bits 32 192 kHz 30 dBFS Adjustable from 6 to 6 dBu Control network Type Connection Proprietary GLM network 2 RJ45 CAT5 cables Crossover frequency 2 6 kHz GLMTM software frequency response adjustment Parametric notch filters Shelving filters 16 2 LF and 2 HF System r...

Отзывы: