background image

5

Mounting Options

The vibration insulating Isolation Positioner/Decoupler™ (Iso-

Pod™) table stand allows tilting of the monitor for correct 

alignment of the acoustic axis. The stand can be attached 

to three points on the enclosure, allowing vertical and two 

horizontal positions. Aim the monitor so that its acoustic axis 

point towards the listening position (see Figure 3). Vertical 

orientation is preferable, as this eliminates acoustical cancellation 

problems around the crossover frequency. Place the monitors 

symmetrically at equal distances from the listening position. If 

possible, place the listening position on the left-right centerline 

of the room (see Figure 4). When a monitor far away (1 to 2.2 

m, 3-7 ft) from the acoustically hard wall behind the monitor, an 

acoustic reflection from the wall may cause cancellation of low 

frequencies and reduce bass output. 

Acoustic reflections from objects like desks, cabinets, computer 

monitors etc. can cause unwanted colouration and blurring of 

the sound image. Minimise these by placing the monitors away 

from acoustically reflective surfaces. Putting the monitors on 

stands behind and above a mixing console usually improves the 

response over placing monitors on a meter bridge. Symmetrical 

positioning of the sound reflecting objects maintains a balanced 

soundstage (see Figure 4).

A wide variety of ceiling and wall mounts are available through 

your Genelec dealer. The 8340A can be fitted with König & 

Meyer monitor mounts using two M6 x 10 mm threaded holes 

on the enclosure back. There is an M10 x 10 mm threaded 

hole in the base of the monitor. Do not use this thread for 

mounting the monitor on a microphone stand. Monitor stands 

typically have an incompatible 3/8” UNC thread. A wide 

selection of accessories is available for Genelec monitors. 

Consult the Genelec Accessories Catalogue at www.genelec.

com or your local distributor/dealer for information.

Front Panel Light

Normally, the light on the front panel is green, indicating normal 

operational mode. Red and yellow colours are used to indicate 

special situations. See Table 2 above. 

Use with Subwoofers 

Genelec recommends using the 7300 series subwoofers. For 

more detailed system configuration and matching products, 

please consult the on-line Genelec Product Selection Tool at 

www.genelec.com.

Maintenance

There are no user serviceable parts inside the monitor. 

Maintenance or repair must only be done by a Genelec certified 

service. 

Table 2. Monitor front panel light indications summary

Colour

Indication

Solid greed

Normal state, normal operation

Blinking green

GLM is adjusting the monitor

Green blink every 10 sec.

Monitor is an ISS power saving sleep 

state

Red blink

Power amplifier overload protection is 

active (audio is modified because of 

protection)

Solid red

Monitor is muted

Yellow

Monitor is not in the active (playing) 

group

Yellow blinking

Overheat protection is active (audio is 

modified because of protection)

overloading the monitor. If the AES/EBU cable is operated in 

dual-wire mode, the monitor detects this automatically and the 

channel selection switches have no effect.

Level

The Level switches scale down the monitor output level in 10 dB 

steps. The effects of these switches add up and combine with 

the effect of the rotary level adjustment control. The combined 

total setting range is 42 dB.

Stored

Stored switch selects the use of the controls on the monitor’s 

back panel or the settings stored inside the monitor memory 

using the GLM system calibration software. Setting the Stored 

switch to OFF position selects the settings defined by the 

monitor’s own controls. Setting the Stored switch to ON position 

selects the use of internally stored GLM settings. Using the 

Stored option overrides all adjustments done with the monitor’s  

own controls.

Operating Environment

These monitors are designed for indoor use only. The permissible 

ambient temperature is 15-35 degrees Celsius (50-95°F) and 

relative humidity 20% to 80% (non-condensing). When the 

product has been stored or transported in cool environment and 

is taken into a warm room, wait 0.5-1 hours before opening any 

packing to prevent condensation of humidity before connecting 

to mains power. Sufficient cooling must be ensured. The 

minimum clearance is 50 mm (2 in) behind, above and on both 

sides of the monitor. The space must be ventilated sufficiently 

to dissipate the heat. 

Mounting and Placing Monitors 

Содержание SAM 8340A

Страница 1: ...8340A Operating Manual ...

Страница 2: ...fers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup and the use of GLM in the GLM System Operating Manual The setup is fast and consists of ...

Страница 3: ...nd 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control The Bass Tilt control switches swiches 3 and 4 offer three at tenuation levels for the bass response below 800 Hz usually necessary when the monitors are placed near room boundaries The ...

Страница 4: ...Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Figu...

Страница 5: ...ubwoofers Genelec recommends using the 7300 series subwoofers For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance There are no user serviceable parts inside the monitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour I...

Страница 6: ...d Genelec service The monitor enclosure must not be opened Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not...

Страница 7: ...l drivers are magnetically shielded 165 mm 61 2 in cone 19 mm 3 4 in metal dome Weight 8 4 kg 18 5 lb Dimensions Height Width Depth Height with Iso Pod 350 mm 1313 16 in 237 mm 93 8 in 223 mm 813 16 in 365 mm 143 8 in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If...

Страница 8: ...gital input sensitivity 100 dB SPL at 1 m Digital input gain sensitivity rotary control AES EBU Single Wire AES EBU Single Wire 16 24 bits 32 192 kHz 30 dBFS Adjustable from 6 to 6 dBu Control network Type Connection Proprietary GLM network 2 RJ45 CAT5 cables Crossover frequency 2 6 kHz GLMTM software frequency response adjustment Parametric notch filters Shelving filters 16 2 LF and 2 HF System r...

Отзывы: