background image

6

Figure 7. The curves above show the effect of the “Bass 

Tilt”, “Treble Tilt”, “Desktop Low Frequency” and “Bass 

Roll-Off” controls on the free field response of the 8340A. 

Figure 8. The upper curve group shows the horizontal di-

rectivity characteristics of the 8340A measured at 1 m. The 

lower curve shows the system’s power response.

20

20k

50

100

200

500

1k

2k

5k

10k

Hz

Genelec Oy 8340 horizontal off axis response level (dBr) vs freq (Hz) 10 Mar 16

60°

15°

30°

45°

50

100

55

60

65

70

75

80

85

90

95

d

B

r

A

20

20k

50

100

200

500

1k

2k

5k

10k

Hz

Genelec Oy 8340A

1 April 2016

80

85

90

d

B

r

A

BASS ROLL-OFF

TREBLE TILT

80

85

90

80

85

90

DESKTOP LF

BASS TILT

Figure 9. The curve above shows the delay variation of the 

8340A as a function of frequency.

20k

50

100

200

500

1k

2k

5k

10k

Hz

Genelec Oy 8340

29 April 2016

ms

5

0

10

15

35

20

25

30

40

Safety Considerations

Although the 8340A has been designed in accordance with in-

ternational safety standards, to ensure safe operation and to 

maintain the monitor under safe operating conditions, the fol-

lowing warnings and precautions must be observed:

•  Servicing and adjustment must only be performed by a 

certified Genelec service. The monitor enclosure must not 

be opened.

•  Do not use this product with an unearthed mains cable or 

a mains connection without the protective earth contact as 

this may lead to personal  injury.

•  To prevent fire or electric shock, do not expose the unit to 

water or moisture. 

•  Do not place any objects filled with liquid, such as vases on 

the monitor or near it. 

•  Note that the amplifier is not completely disconnected 

from the AC mains service unless the mains power cord is 

removed from the amplifier or the mains outlet.

•  Free flow of air behind the monitor is necessary to maintain 

sufficient cooling. 

•  Do not obstruct airflow around the monitors.

WARNING! 

These monitors are capable of producing sound pressure levels 

in excess of 85 dB, which may cause permanent hearing dam-

age.

Guarantee

The Genelec 8340A is guaranteed for two years against 

manufacturing faults or defects altering performance. Refer to 

the reseller for full sales and guarantee terms.

Compliance to FCC Rules

Note: This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and can 

radiate radio frequency energy and, if not installed and used in 

Содержание SAM 8340A

Страница 1: ...8340A Operating Manual ...

Страница 2: ...fers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup and the use of GLM in the GLM System Operating Manual The setup is fast and consists of ...

Страница 3: ...nd 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control The Bass Tilt control switches swiches 3 and 4 offer three at tenuation levels for the bass response below 800 Hz usually necessary when the monitors are placed near room boundaries The ...

Страница 4: ...Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Figu...

Страница 5: ...ubwoofers Genelec recommends using the 7300 series subwoofers For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance There are no user serviceable parts inside the monitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour I...

Страница 6: ...d Genelec service The monitor enclosure must not be opened Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not...

Страница 7: ...l drivers are magnetically shielded 165 mm 61 2 in cone 19 mm 3 4 in metal dome Weight 8 4 kg 18 5 lb Dimensions Height Width Depth Height with Iso Pod 350 mm 1313 16 in 237 mm 93 8 in 223 mm 813 16 in 365 mm 143 8 in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If...

Страница 8: ...gital input sensitivity 100 dB SPL at 1 m Digital input gain sensitivity rotary control AES EBU Single Wire AES EBU Single Wire 16 24 bits 32 192 kHz 30 dBFS Adjustable from 6 to 6 dBu Control network Type Connection Proprietary GLM network 2 RJ45 CAT5 cables Crossover frequency 2 6 kHz GLMTM software frequency response adjustment Parametric notch filters Shelving filters 16 2 LF and 2 HF System r...

Отзывы: