background image

Figure 8. Connector panel of the RAM-XL amplifier.

Figure 7. Selecting ISS setting.

Single-wire mode of AES/EBU is the 

default and the older dual-wire mode is 
automatically detected if used at the source. 

The standard AES/EBU cable carries 

two channels of audio, called A and B. As 
a default, both A and B subchannels are 
reproduced by the monitor. GLM software 
is used to set up the monitor to specific 
channel assignments. 

RAM-XL Amplifier  

Power Button

The power button in the middle of the 
RAM-XL amplifier front panel controls 
several functions. 

A short press of the power button turns 

the RAM-XL on or off. Turning on, the power 
button light flashes rapidly, and lights 
on steadily when the turn-on has been 
completed.  Testing modes are explained 
later in this manual.

Setting ISS™ 

The Intelligent Signal Sensing™ (ISS™) 
puts the monitor to a power-saving 
stand-by mode automatically. The factory 
setting for ISS is "OFF." The ISS can be 
activated using the GLM software (see 
Figure 5). When ISS is active, if no audio 
signal is sensed during the selected time, 
the monitor powers down. The monitor will 
power up again once a signal is detected. 
The ISS setting is applied to all ISS-enabled 
monitors in the currently selected Setup. 

Connectors on the RAM-XL

 

“MAINS INPUT” Connector

Connect to the mains supply of 100 - 120 

VAC or 220 - 240 VAC 50/60 Hz.

 “DIGITAL IN AES/EBU” Connector

The monitor defaults to reproducing an 
analog input signal. The digital audio 
AES/EBU input is selected automatically 
when a valid digital audio signal is 
presented. Use GLM software to define 
the AES/EBU subframe to monitor. 

 “DIGITAL THRU AES/EBU” Connector

This output carries an unaltered copy of 
the digital audio signal and can be used 
for daisy-chaining the signal to up to three 
additional SAM monitors or subwoofers.  

“ANALOG IN” Connector

The maximum input level of the analog 
input is +25.0 dBu. The analog input must 
not be overloaded, otherwise distortion 
will result. When the maximum input is 
exceeded, the enclosure front panel light 
turns red, indicating the overload. 

The sensitivity of the monitor 

system is set using the GLM software. 
Coming from the factory, the analog 
input is set to the highest sensitivity, 
resulting in a sound output of 100 dB 
SPL for a -6 dBu analog input signal.  

“CONTROL NETWORK” Connectors

The RJ45 sockets connect the monitor 
to the proprietary Genelec Loudspeaker 
Manager™ (GLM™) network. Do not 
connect to Ethernet LAN. 

“Loudspeaker Connectors” Group

“LED” Connector
This RJ45 socket is a connection for the 
front panel warning LED.

LOUDSPEAKER CONNECTORS

WOOFER

MIDRANGE / TWEETER

WARNING

ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT TO WATER OR MOISTURE.

RACCORDÉ À LA TERRE.

AVERTISSEMENT

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. CET APPAREIL DOIT ÊTRE

RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS EXPOSER À L'EAU OU

L'HUMIDITÉ. AUCUN COMPOSANT À L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR.

LAITE ON LIITETTÄVÄ SUOJAMAADOITUSKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN.

APPARATET MÅ TILKOPLES JORDET STIKKONTAKT. APPARATEN SKALL ANSLUTAS TILL

JORDAT UTTAG.

CONNECT ONLY TO GENELEC NETWORK

CONTROL NETWORK

MAINS INPUT

50 / 60 Hz 1000 W

100 - 120 V~

220 - 230 V~

ANALOG

IN

DIGITAL IN

AES/EBU

DIGITAL THRU

AES/EBU

SERIAL NUMBER

RAM-XL AMPLIFIER

MODULE

www.genelec.com

MADE IN FINLAND

USE EARTHED MAINS CONNECTION ONLY.

THIS AMPLIFIER HAS BEEN CALIBRATED FOR USE WITH THE LOUDSPEAKER MARKED WITH

THE SAME SERIAL NUMBER. DO NOT MIX THE CALIBRATED AMPLIFIER/LOUDSPEAKER

PAIRS ! TURN OFF POWER BEFORE DISCONNECTING LOUDSPEAKER CONNECTIONS !

NOTE !

LED CONNECTOR

This device complies

with FCC Part 15 and

Canadian ICES-003

radio frequency Class

A emission

requirements. Refer

to operating manual

for full information.

2

1

3

THRU

IN

1

1

2

3

3

2

-

GND
+

ANALOG

SIGNAL

INPUT

CONNECTOR

DIGITAL SIGNAL

INPUT AND THRU

CONNECTORS

CONTROL

NETWORK

CONNECTORS

LED

CONNECTOR

COOLING FAN

(GRILLE NOT SHOWN)

WOOFER AND

MIDRANGE/TWEETER

CONNECTORS

MAINS INPUT

CONNECTOR

“Woofer” Connector
A standard four-pole Speakon cable 
connects to the woofers.

“Midrange/Tweeter” Connector
A standard four-pole Speakon cable 
connects to the midrange and tweeter.

CAUTION! 

The ”Woofer” and ”Midrange/

Tweeter” connectors on the RAM-XL 
amplifier can output hazardously high 
voltages. To ensure safety, the wiring 
connected to these connectors must be 
installed by a qualified and trained person.

Front Panel Light Functions

The green light on the DCW panel of 
a 1236A enclosure indicates normal 
operation. A yellow light indicates certain 
activities when the GLM control software 
is used. The light turns red in an overload 
condition. The overload light (red) is 
activated by several events:

•  Exceeding the maximum input of the 

analog input

•  Reaching close to the digital input 

maximum (high likelihood of digital 
clipping)

•  Overload of drivers or amplifier, or 

clipping in the power amplifier 

•  An error detected in the AES/EBU 

audio data

If a red warning light appears on the 
monitor, turn the source level down. Ensure 
that there are no bit errors in the AES/EBU 
digital audio data transmission.

Содержание SAM 1236A

Страница 1: ...Genelec 1236A Smart Active Monitor Operating Manual 1236A ...

Страница 2: ... following cable kit One mains cable Two 10 m 32 ft 9 in 4 pole Speakon cables One 10 m 32 ft 9 in RJ45 cable One 5 m 16 ft 4 in RJ 45 cable The 10 m cables are designed to go between the amplifier and the monitor enclosure If you need to make custom length cables for this please connect the Speakon cables pin to pin and see Table 1 for recommended wire gauges Amplifier Positioning The RAM XL ampl...

Страница 3: ...d the enclosure with a facing panel this should be fixed to the wall Leave a gap of about 5 10 mm in between the enclosure and the panel Fill this gap with a soft rubber gasket to allow for possible enclosure movement Ensure that the speaker cables can reach the rear of the enclosure If a light e g wooden but heavily braced wall is used the monitor enclosure should be mounted on vibration isolator...

Страница 4: ...d from the socket Set up and Use The 1236A is set up using the GLM software The setup is fast and consists of the following steps Figure 6 GLM network cabling audio cabling not shown Link all monitors and subwoofers in a daisy chain by running CAT5 RJ45 network cables from the Network Adaptor to the CONTROL NETWORK connectors of the RAM XL modules and then on to the remaining monitors in the contr...

Страница 5: ...Connector This RJ45 socket is a connection for the front panel warning LED LOUDSPEAKER CONNECTORS WOOFER MIDRANGE TWEETER WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE RACCORDÉ À LA TERRE AVERTISSEMENT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ CET APPAREIL DOIT ÊTRE RISQUE DE CHOC ÉLECTR...

Страница 6: ... of increased heat load due to a blockage In an extreme case the amplifier may automatically shut off Safety Considerations Although this product has been designed in accordance with international safety standards to ensure safe operation and to maintain the monitor under safe operating conditions the following warnings and precautions must be observed Servicing and adjustment must only be perform...

Страница 7: ...perienced radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship The guarantee can be extended by three years by registering the product at www genelec com Refer to supplier for full sales a...

Страница 8: ...nitor enclosure dimensions Height Width Depth 960 mm 373 4 in 1180 mm 461 2 in 650 mm 255 8 in Amplifier dimensions Height Width front plate Width casing Depth 3U 132 mm 53 16 in 483 mm 19 in 425 mm 163 4 in 286 mm 111 4 in 1236A Bass amplifier short term output power Midrange amplifier short term output power Treble amplifier short term output power 2 x 1000 W 2 x 400 W 250 W Long term output pow...

Отзывы: