background image

Figure 1. The location of the acoustic axis. 

and frequency response. 

The monitor enclosure has its acoustical 

axis midway between the midrange and 
treble drivers. This axis should be used 
as the listening and measuring axis of the 
system. (See Figure 1 and 2).

The typical listening distance varies 

between 2 and 3.5 m (6½ and 11½ ft) from 
the monitors. The monitor should be aimed 
so that the vertical acoustical axes of the 
two monitors meet midway between the 
standing and seated listening position (1.4 
m – 4 ft 7 in from the floor). This allows 
the correct frequency response to be 
received by a standing or seated person. 
The monitors should not be mounted too 
high as this increases the required vertical 
tilt of the monitor and reduces the optimum 
listening area.

The ceiling, side walls and especially the 

rear wall should be acoustically absorbent 
at low frequencies. The monitor mounting 
wall should be acoustically hard and 
therefore reflective. The monitor mounting 
wall should be angled so that the monitors 
are correctly aimed. Great care should be 
taken over how the monitor is mounted into 
the solid and sturdy wall structure.

Note the following:

A space 50…100 mm (2…4 in) wide can be 
left around the monitor enclosure.

Cover the space around the enclosure 

with a facing panel, this should be fixed 
to the wall. Leave a gap of about 5…10 
mm (¼…½ in) between the enclosure and 
the panel. Fill this gap with a soft rubber 
gasket to allow for possible enclosure 
movement. Ensure that the speaker cables 
can reach the rear of the enclosure. If a 
light (e.g. wooden), but heavily braced, 
wall is used, the monitor enclosure should 
be mounted on vibration isolators with a 
resonant frequency of around 2…8 Hz, to 
prevent vibrations from being transmitted 
to the wall and impairing the low frequency 
performance. The space around the 
enclosure should be filled with absorbent 
mineral wool or foam plastic. The walls 
must be well braced.

For a solid wall (e.g. concrete), the 

enclosure may be directly mounted to the 
wall without vibration isolators. The space 
around the enclosure should be filled with 
mineral wool or sand bags.

Discontinuities in the enclosure mounting 

Cable gauge

Max. length

2,0 mm

2

 (14 AWG)

30 m (100 ft)

3,3 mm

2

 (12 AWG)

40 m (130 ft)

5,3 mm

2

 (10 AWG)

60 m (200 ft)

Table 1. Recommended cable thicknesses 
for different lengths of speaker cable

Figure 2. Monitor enclosure  
mounting. 

Figure 3. Monitor enclosure mounting 
details. 

Figure 4. Eliminating discontinuities. 

Figure 5. Recess needed for speaker 
cable connectors (front view). 

830 mm

32 3/4 in

508 mm

20 in

858 mm

33 3/4 in

480 mm

18 7/8 in

>2

m

>2

m

299 mm

11 3/4 in

200 mm

7 7/8 in

681 mm

26 13/16 in

31

1

m

m

12

1/4

in

180

mm

7

3/32

in

469

mm

18

1/2

in

Содержание SAM 1236A

Страница 1: ...Genelec 1236A Smart Active Monitor Operating Manual 1236A ...

Страница 2: ... following cable kit One mains cable Two 10 m 32 ft 9 in 4 pole Speakon cables One 10 m 32 ft 9 in RJ45 cable One 5 m 16 ft 4 in RJ 45 cable The 10 m cables are designed to go between the amplifier and the monitor enclosure If you need to make custom length cables for this please connect the Speakon cables pin to pin and see Table 1 for recommended wire gauges Amplifier Positioning The RAM XL ampl...

Страница 3: ...d the enclosure with a facing panel this should be fixed to the wall Leave a gap of about 5 10 mm in between the enclosure and the panel Fill this gap with a soft rubber gasket to allow for possible enclosure movement Ensure that the speaker cables can reach the rear of the enclosure If a light e g wooden but heavily braced wall is used the monitor enclosure should be mounted on vibration isolator...

Страница 4: ...d from the socket Set up and Use The 1236A is set up using the GLM software The setup is fast and consists of the following steps Figure 6 GLM network cabling audio cabling not shown Link all monitors and subwoofers in a daisy chain by running CAT5 RJ45 network cables from the Network Adaptor to the CONTROL NETWORK connectors of the RAM XL modules and then on to the remaining monitors in the contr...

Страница 5: ...Connector This RJ45 socket is a connection for the front panel warning LED LOUDSPEAKER CONNECTORS WOOFER MIDRANGE TWEETER WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE RACCORDÉ À LA TERRE AVERTISSEMENT NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ CET APPAREIL DOIT ÊTRE RISQUE DE CHOC ÉLECTR...

Страница 6: ... of increased heat load due to a blockage In an extreme case the amplifier may automatically shut off Safety Considerations Although this product has been designed in accordance with international safety standards to ensure safe operation and to maintain the monitor under safe operating conditions the following warnings and precautions must be observed Servicing and adjustment must only be perform...

Страница 7: ...perienced radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship The guarantee can be extended by three years by registering the product at www genelec com Refer to supplier for full sales a...

Страница 8: ...nitor enclosure dimensions Height Width Depth 960 mm 373 4 in 1180 mm 461 2 in 650 mm 255 8 in Amplifier dimensions Height Width front plate Width casing Depth 3U 132 mm 53 16 in 483 mm 19 in 425 mm 163 4 in 286 mm 111 4 in 1236A Bass amplifier short term output power Midrange amplifier short term output power Treble amplifier short term output power 2 x 1000 W 2 x 400 W 250 W Long term output pow...

Отзывы: