10
Figure 8. Balanced analogue input pin-out (left) and daisy-chaining cables in the
analogue input Euroblock connector (right).
GENELEC SMART IP MANAGER SOFTWARE
Acoustic calibration, zone setup, input selection and loudspeaker management
are done using Genelec Smart IP Manager software. This is a software intended
for AV installers. Genelec recommends using the Application Programming
Interface (API) inside the loudspeaker to be used with house automation systems
for the end-user control.
Download Smart IP Manager at https://www.genelec.com/smartipmanager
https://www.genelec.com/smart-ip-manager and follow screen instructions to
install. For detailed use of the Genelec Smart IP manager software, please refer
to Smart IP Manager operating manual.
Zone settings
A zone is a collection of loudspeakers working as a system. The settings
collectively applied to a selection of loudspeakers called the Zone includes
mute
zone level control
settings profile selection
Normally, level is adjusted at the stream source. In the Smart IP manager
software, the output level of the Zone or a complete system can be set by
adjusting the level in the Smart IP Manager software using the ‘-‘ and ‘+’ buttons.
Each zone can have up to five different Profiles. A Profile contains a collection of
settings including settings of all acoustical controls, the input selection and the
level and delay alignments. These are first designed and stored in each
loudspeaker. Then, each zone can work as a system. Selecting a Profile will
collectively recall all setting stored under this profile in each loudspeaker
belonging into this Zone.