background image

personnel. The monitor enclosure or 
the amplifier enclosure must not be 
opened.

2.  Do not use this product with a 

mains cable with no protective earth 
conductor, or a mains connection 
without the protective earth contact, 
as this may lead to personal injury.

3.  To prevent fire or electric shock, 

do not expose the unit to water or 
moisture. 

4.  Do not place any objects filled with 

liquid, such as vases or water pipes 
on the amplifier or near it. 

5.  Note that the amplifier is not 

completely disconnected from the AC 
mains service unless the mains power 
cord is removed from the amplifier 
or the mains outlet. Easy access to 
either end of the power cord must be 
ensured at all times.

6.  Free flow of air around the amplifier 

is necessary to maintain sufficient 
cooling. Do not obstruct airflow 
around the amplifier.

WARNING! 

The Genelec 1238DF monitor is capable of 
producing sound pressure levels in excess 
of 85 dB, which may cause permanent 
hearing damage.

Symbols

WEEE Directive 2012/19/EU

Power/standby switch

Maintenance

No user serviceable parts are to be found 
within the monitor enclosure or the RAM-L 
amplifier unit. Any maintenance or repair of 
the monitor should only be undertaken by 
qualified service personnel. 

Guarantee

The Genelec 1238DF is supplied with a 
two year guarantee against manufacturing 
faults or defects that might alter the 

Figure 6. Flush mounting the speaker in 
a wall constructed of wood

Figure 7. Flush mounting the speaker in 
a wall constructed of concrete

Figure 8. Flush mounting the speaker 
in a wall constructed of a combination 
of materials.

CONCRETE

STRUCTURE

VIBRATION

ISOLATORS

f ~ 2-8 Hz

MULTI-LAYERED WALL

(WOOD, CONCRETE, BRICKS)

VIBRATION

ISOLATORS

f ~ 2-8 Hz

CONCRETE WALL

SAND

BAGS

VIBRATION

ISOLATORS

f ~ 2-8 Hz

HEAVY WOODEN WALL

ABSORBING

MATERIAL

Testing Mode

Once on, when the power button is 
pressed for a long time, the RAM-L enters 
a mode for system testing. This special 
mode is intended for system debugging 
and testing. When the RAM-L is turned 
off, the special mode is reset. Upon 
restarting the RAM-L the current standard 
settings stored by GLM software are 
restored. 

Test mode selection blinks the power 

button light (see Table 2). A special mode 
is activated by a long press on the power 
button. In a special mode the power button 
light remains on but blinks off 1-4 times 
indicating the mode currently selected. 

The testing modes are not intended for 

continued operation. Use GLM software to 
set up permanent settings for 1238DF.  

Safety Considerations

The 1238DF has been designed in 
accordance with international safety 
standards. To ensure continued safe 
operation and to maintain the monitor 
under safe operating conditions, the 
following warnings and precautions must 
be observed:

1.  Servicing and adjustment must only 

be performed by qualified service 

FACING PANEL

FIXED TO THE WALL

(50-100 mm / 2-4")

RUBBER GASKET

(5-10 mm / ¼-½")

SPEAKER

WALL

Figure 9. Covering the gap between 
the wall and the monitor enclosure.

Содержание 1238df

Страница 1: ...Genelec 1238DF Smart Active Monitor Operating Manual 1238DF ...

Страница 2: ...ssible ambient temperature is 15 35 degrees Celsius 50 95 F and permissible relative humidity between 20 and 80 Humidity condensation on the product is not allowed during use For instance if the product has been stored or transported in a cool environment and then taken into a warm room it must be allowed to warm up to the ambient temperature before connecting to mains power Mounting Consideration...

Страница 3: ...ng Figure 1 The location of the acoustic axis L R C 30 0 RS LS 100 120 0 0 Figure 2 Recommended placement and alignment of monitors in a 5 chan nel system ITU R BS 775 1 Figure 4 Connector panel of the RAM L amplifier LED CONNECTOR CONNECT ONLY TO GENELEC NETWORK ANALOG IN DIGITAL IN AES EBU DIGITAL THRU AES EBU MAINS INPUT 50 60 Hz 750 W 100 230 V SERIAL NUMBER MIDRANGE TWEETER WOOFER LOUDSPEAKER...

Страница 4: ...ghts on steadily when the turn on has been completed Testing modes are explained later in this manual Setting ISS The Intelligent Signal Sensing ISS puts the monitor to a power saving stand by mode automatically The factory setting for ISS is OFF The ISS can be activated using the GLM software see Figure 5 When ISS is active if no audio signal is sensed during the selected time the monitor powers ...

Страница 5: ...he speaker in a wall constructed of wood Figure 7 Flush mounting the speaker in a wall constructed of concrete Figure 8 Flush mounting the speaker in a wall constructed of a combination of materials CONCRETE STRUCTURE VIBRATION ISOLATORS f 2 8 Hz MULTI LAYERED WALL WOOD CONCRETE BRICKS VIBRATION ISOLATORS f 2 8 Hz CONCRETE WALL SAND BAGS VIBRATION ISOLATORS f 2 8 Hz HEAVY WOODEN WALL ABSORBING MAT...

Страница 6: ...rect the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Modifications not expressly approved by the manufacturer...

Страница 7: ... 15 30 45 50 100 55 60 65 70 75 80 85 90 95 d B r A Figure 10 Horizontal directivity characteristics of the 1238DF Figure 11 Vertical directivity characteristics of the 1238DF Figure 12 Horizontal directivity characteristics of the 1238DF The lower curve is the monitor s power response ...

Страница 8: ...e 25 mm 1 in metal dome Weight Monitor enclosure Amplifier 36 kg 79 lb 6 kg 13 lb Dimensions monitor enclosure Height Width Depth 610 mm 24 in 470 mm 181 2 in 257 mm 101 8 in Amplifier dimensions Height front panel Height amplifier casing Width front panel Width amplifier casing Depth 3U 132 mm 53 6 in 80 mm 31 8 in 483 mm 19 in 425 mm 163 4 in 252 mm 915 16 in 1238DF Bass amplifier short term out...

Отзывы: