background image

• Reflections from nearby boundaries
(Floor, ceiling, walls) interfering with direct
sound.

Incorrect vertical speaker alignment can
cause interference dips at the upper
crossover frequency (around 3.2kHz).
Hence care should be taken aiming the
speaker correctly towards the listening
position. (See Fig 2.)

4.  OVERLOAD INDICATORS

4.  OVERLOAD INDICATORS

4.  OVERLOAD INDICATORS

4.  OVERLOAD INDICATORS

4.  OVERLOAD INDICATORS

Each speaker is provided with two LED's
marked 'CLIP PROTECT (FAULT)' and
'READY'. The green 'READY' LED indi-
cates that the amplifier system power is
switched on, and that the speaker is
ready for use. The red 'CLIP PROTECT
(FAULT)' LED indicates that the amplifier
system is overloaded or that the driver
protection circuit is activated. If the red
LED lights, reduce the signal level so that
the LED stops blinking. If this LED stays lit
constantly, then the amplifier thermal
protection circuitry has activated. Let the
amplifier cool down, and ensure that the
amplifier is adequately ventilated.

5.  MAINTENANCE

5.  MAINTENANCE

5.  MAINTENANCE

5.  MAINTENANCE

5.  MAINTENANCE

There are no user serviceable parts within
the amplifier unit. Any maintenance of the
unit should only be undertaken by quali-
fied service personnel.

 Ensure that only fuses of the appropriate
voltage and current ratings are used if a
fuse has to be replaced.

REMEMBER to disconnect the power
supply by removal of the mains cable
before changing a fuse.

Clean the amplifier unit's air filter every six
months, or more frequently in dusty envi-
ronments. The air filter is located behind
the grille, found to the left of the front
panel. The air filter can be cleaned with a
vacuum cleaner without removing the
grille.

6.  SAFETY CONSIDERATIONS

6.  SAFETY CONSIDERATIONS

6.  SAFETY CONSIDERATIONS

6.  SAFETY CONSIDERATIONS

6.  SAFETY CONSIDERATIONS

Although the 1034BC has been designed
in accordance with international safety
standards, to ensure safe operation and
to maintain the instrument under safe

Signal Source

Use a signal source which is suitable for
the type of analyzer being used. 

Do not

use a noise generator which is integrated
into a mixing console, since these signal
generators tend to have a very coarse
spectrum content and are not intended to
be used for measurement purposes.

Analyzer

Any professional quality real time analyzer
or tracking plotter can be used. (

1

/

or 

1

/

1

octave analysis is usually sufficient for
frequency response balancing)

3.4  NEAR FIELD MEASUREMENT.

This measurement gives an indication of
the direct sound radiation of the loud-
speaker below 1kHz.

• Set the microphone 1m away from the
loudspeaker on the acoustic axis. (See
Fig 1)

• Measure the frequency response of
the speaker, and adjust the tone controls
to achieve a flat frequency response
below 1kHz.

Make sure that any sound reflecting ob-
jects such as chairs etc. are removed
from the close proximity of the loud-
speaker.

3.5  LISTENING POSITION MEASURE-
MENT.

Once the near field frequency response
measurement has been made, the fre-
quency response at the listening position
can be determined by the same means.
When comparing the results, the following
items should be noted.

High frequency roll-off

This is due to the following physical fac-
tors:

• Increasing room and air absorption
with higher frequencies.

• Increasing loudspeaker and micro-
phone directivity with increasing fre-
quency.

Low frequency irregularities.

These are caused by

• Insufficient standing wave absorption
in the control room.

operating conditions, the following warn-
ings and cautions should be observed.

Servicing and adjustment should only be
performed by qualified service personnel.
Opening the amplifier's front panel is
strictly prohibited except by such persons
who are aware of the hazards involved.

It is forbidden to use this product with an
unearthed mains cable, which may lead
to personal injury.

Warning!

This equipment is capable of delivering
sound pressure levels in excess of 85dB,
which may cause permanent hearing
damage.

7.  GUARANTEE

7.  GUARANTEE

7.  GUARANTEE

7.  GUARANTEE

7.  GUARANTEE

This product is guaranteed for a period of
ONE year against faults in materials or
workmanship. Refer to supplier for full
sales and guarantee terms.

Содержание 1034BC

Страница 1: ...ingManual OperatingManual Genelec 1034BC Genelec 1034BC Genelec 1034BC Genelec 1034BC Genelec 1034BC Control Room Monitoring System Control Room Monitoring System Control Room Monitoring System Control Room Monitoring System Control Room Monitoring System ...

Страница 2: ... and the bass re sponse extends down to 27 Hz The high frequency response extends up to 22kHz 3dB The amplifier unit contains a 3 channel active crossover driver overload protec tion circuits and 4 separate power ampli fiers producing 2 x 400W 350W and 120W of short term power in the bass midrange and treble channels respec tively The crossover filter incorporates tone controls to enable the user ...

Страница 3: ...ORS The speaker connector cable extends 100 mm 4 from the rear panel of the loudspeaker Therefore a space at least 100 mm 4 deep must exist to allow for the cable connectors behind the loud speaker The dimensions of the recess should be at least 100x150x120 mm 4 x51 2 x43 4 as shown in Fig 5 Note that the connectors are positioned off centre Ensure that there are no sharp bends on the speaker cabl...

Страница 4: ...e front panel of the amplifier unit However an accu rate left right balance is obtained when the trimmer is set to the fully clockwise cal position Leaving the input sensitivity trimmer in the cal position is therefore recommended To obtain the maximum sound pressure level of 123 dB SPL with the input sensi tivity set to 6 dBu a signal level of 20 dBu is required 3 2 ADJUSTMENT OF THE TONE CON TRO...

Страница 5: ...nal source which is suitable for the type of analyzer being used Do not use a noise generator which is integrated into a mixing console since these signal generators tend to have a very coarse spectrum content and are not intended to be used for measurement purposes Analyzer Any professional quality real time analyzer or tracking plotter can be used 1 3 or 1 1 octave analysis is usually sufficient...

Страница 6: ...output Bass 100 dB Mid 100 dB Treble 100 dB Mains voltage 100 200 or 115 230V Voltage operating range at 230V setting 207 244 V 10 6 115V setting 104 122 V 10 6 Powerconsumption Idle 70 W Full output 1000 W Amplifierweight 30 kg 66 lb Amplifier dimensions Height 310 mm 123 16 Width 483 mm 19 Depth 250 mm 913 16 Input connector XLR female pin 1 gnd pin 2 pin 3 Inputimpedance 10 kOhm balanced Input ...

Отзывы: