3. Transport and Storage 

 

  All

 

products are packed in sturdy packing. During transport measures should 

be adopted in order to prevent impacts, hits. 

  Storage must be off the floor, covered with a sealed dust protector. 

  While commissioning, Genebre, S.A. recommend a visual inspection in order to 

                detect any anomaly caused during the transport, handling or during the 
                storage.

 

 

 
4. Pre-Installation Inspection 

 

  Verify the product nameplate to insure correct model number, before installation or 

use. 

  If there is any discrepancy, please contact with our local distributor, or Genebre, 

S.A., to solve that discrepancy. 

 

 

 
5. External Electrical Connections 

 
                                      

 

 

 

 
 
 
 

         Safety instructions on chapter 2 must be observed. Work on electrical system 
         or equipment must only be carried out by skilled electrician.

 

 
 
 
 
 

 

Under no circumstances should any modification or alteration be carried out 
on the actuator as this could very well invalidate the conditions which the 
device was designed. 

As electric device, during electrical operation certain parts inevitably carry 
lethal voltages and currents (ELECTRICAL RISKS). 

 

 

 

Содержание 5810 04

Страница 1: ...italet de Llobregat Barcelona Spain genebre genebre es www genebre es GENEBRE S A FECHA DE REVISI N 07 05 2019 NUMERO DE REVISI N 2 INSTALLATION OPERATION MAINTENANCE MANUAL Digital Positioning System...

Страница 2: ...RO DE REVISI N 2 INSTRUCTIONS FOR INSTALLATION OPERATION MAINTENANCE MANUAL 1 Product Description 3 2 Safety Instructions 3 3 Transport and Storage 4 4 Pre Installation Inspection 4 5 External Electri...

Страница 3: ...gn position input is converted to a digital numerical value and is continuously compared with the position of potentiometer which is mechanically fitted to the valve shaft The programme in the microch...

Страница 4: ...ling or during the storage 4 Pre Installation Inspection Verify the product nameplate to insure correct model number before installation or use If there is any discrepancy please contact with our loca...

Страница 5: ...LS Close Limit Switch 250 VAC 10A OLS Open Limit Switch 250 VAC 10A CTS Aux Close Torque Switch 250 VAC 10A OTS Aux Open Torque Switch 250 VAC 10A ACLS Aux Close Limit Switch 250 VAC 10A AOLS Aux Open...

Страница 6: ...LS Close Limit Switch 250 VAC 10A OLS Open Limit Switch 250 VAC 10A CTS Aux Close Torque Switch 250 VAC 10A OTS Aux Open Torque Switch 250 VAC 10A ACLS Aux Close Limit Switch 250 VAC 10A AOLS Aux Open...

Страница 7: ...NTS UNLESS SPECIAL PRECISE ADJUSTMENTS ARE REQUIRED 7 Signal Control 7 1 Signal Types The signal types can be 4 20 mA or 0 10V DC If there is no instruction for the input signal Genebre set the signal...

Страница 8: ...N A Off On Without signal valve position full close N C Note The standard configuration for Genebre is the 4 switches in Off 7 3 Auto Setting If actuator is properly mounted on application please che...

Страница 9: ...Flicker Automatic Calibration V Red Light On Lost Signal W Red Light On Over Torque X Red Light On Blocked or Reverse Y Red Light On Calibration Error 9 Maintenance These actuators are free maintenanc...

Отзывы: