background image

GENANO L

TD

 

 

GENANO ®TECHNOLOGY                                                  G310 LOG_ UM_ENG V2.3 

TT /JSan

 

GENANO 310 OPERATING INSTRUCTION                                                Page 5

 

Genano Ltd. 

 

Tel.   +358 (9) 7743 870 

Kimmeltie 3 

 

Fax. +358 (9) 7743 8711 

FIN-02110 ESPOO 

 

email: [email protected] 

www.genano.fi 

 
 

INSTALLATION AND OPERATING INSTRUCTIONS 

 

 
PARTS AND INDICATIONS OF SYMBOLS 

 

A.  BOTTOM BASIN (basin for flush water / clean water container)

 

 

 

B.  SIGNAL LIGHTS  
 

-

 

OPERATION 
Green light 

 

-

 

AUTOMATIC WASH/DRYING 
Green light

 

 

-

 

CLOSE BASIN 
Green light

 

 

-

 

ERROR/SERVICE 
Red light

 

 

-

 

FILL WATER 
Yellow light

 

 
 

C.  OPERATION SWITCHES 

 

-

 

MAIN SWITCH (ON/OFF)  

 
 

 

-

 

POWER WASH  

 
 

 

 

 

 

-   FAN SETTINGS/CAPASITY 

 
 
 

 
BEFORE USE 

 

This product should always be transported in a vertical position. If transported horizon-
tally let device dry 8 hours in vertical position before switching on. 
 
Standing vertically on a stable, even base or wall mount.

 

 

ATTENTION: NEVER USE HORIZONTALLY

 
 

 

 

 

A) 

B) 

 

C) 

 

 

OK

 

 

 

 

 

 

 

 

 

100m

3

/h

 

to

 

250 m

3

/h 

*Maximum air volume 
output may vary depending 
on air purification needs and 
version type

 

 

 

Содержание 310

Страница 1: ...CHNOLOGY GENANO 310 AIR PURIFICATION DEVICE OPERATING INSTRUCTION This manual is for the Genano 310 log Version GENANO LTD Kimmeltie 3 FI 02110 Espoo FINLAND Tel 358 0 9 7743 870 Fax 358 0 9 7533 130 www genano fi info genano fi ...

Страница 2: ...DOOR CLIMATE 3 IMPORTANT SAFETY INSTRUCTIONS 3 CONTENTS 4 TECHNICAL FEATURES 4 INSTALLATION AND OPERATING INSTRUCTIONS 5 PARTS AND INDICATIONS OF SYMBOLS 5 BEFORE USE 5 INSTALLATION 6 WASHING LIQUID 6 POSITIONING 6 WALL MOUNTING 7 OPERATION OF THE DEVICE 7 NORMAL OPERATION 7 RUNNING OUT OF WASHING LIQUID 8 ERROR SERVICE 9 RESETTING PROGRAM SETTINGS 9 POWER WASH 9 GAS ABSORPTION PLATE 10 WARRANTY 1...

Страница 3: ...fficially certified that the cleaning results exceed 98 for atmospheric particles and microbs in the 0 003 10µm range IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance When using an electric air cleaning device basic precautions should always be followed including the following DANGER To reduce the risk of electric shock 1 Do not reach for a plug of an air purifier de...

Страница 4: ...e contains 1 gas absorber to han dle gas emissions Make sure filter is changed annually TECHNICAL FEATURES Use Indoor air environment only Dimensions 450mm x 385mm x 1470mm Weight approx 55kg Chassis Aluminum zinc coated steel Capacity 100 250m3 h Operating voltage 200 240V 50 60Hz Power consumption 140W max Cleaning range 0 001µm Ambient temperature 5 60 C Humidity level of air 0 95 Positioning s...

Страница 5: ...ON Green light AUTOMATIC WASH DRYING Green light CLOSE BASIN Green light ERROR SERVICE Red light FILL WATER Yellow light C OPERATION SWITCHES MAIN SWITCH ON OFF POWER WASH FAN SETTINGS CAPASITY BEFORE USE This product should always be transported in a vertical position If transported horizon tally let device dry 8 hours in vertical position before switching on Standing vertically on a stable even ...

Страница 6: ... main cable into a grounded power socket 5 Push the main switch into ON position LOCK THE BOTTOM BASIN WHEN OPERATED NEAR CHILDREN OR PETS WASHING LIQUID Genonex is premixed so just pour into watering container and pour in container g Take 1 5 liters of distilled water and 1 dcl of Genano MFI washing fluid and mix in the watering can provided POSITIONING When position your unit please try to obser...

Страница 7: ...hold ers on the back of the 310 unit picture 2 OPERATION OF THE DEVICE NORMAL OPERATION Genano 310 is cleaning air when OK light is illuminated The device efficiently collects atmospheric particles on the collection surfaces Washing of the collection surfaces takes place automatically once a week Important It is recom mended to let the unit be continuously ON to ensure the weekly washing During th...

Страница 8: ...al lights The 310 will continue its normal air cleaning operation even if one automatic wash cycle is missed due to a lack of washing mixture However the device stops the air cleaning opera tion if washing liquid water is still not added after week to the wash water container Fill up the water container according to instructions given in the info sheet Do not switch the unit OFF The yellow FILL WA...

Страница 9: ...RESETTING PROGRAM SETTINGS 1 Switch the unit OFF and wait about 20 seconds 2 Switch ON POWER WASH The power wash function can be performed by using the power wash switch check c op eration switches on page 5 This operation is useful if the air cleaning operation is inter rupted due to increased dirtiness of the collection surface The flashing ERROR SERVICE light illustrates the device is extremely...

Страница 10: ...PTION PLATE Besides particles the Genano air cleaner can also remove gases Using a gas absorption plate different kinds gases can be removed from the indoor air e g traffic originated sulphur and nitrogen oxides as well as ozone The typical exchange period of the gas absorption plate is 12 months Gas absorber replacement can only be performed by service personnel authorised by Genano Ltd ATTENTION...

Страница 11: ...O LTD GENANO TECHNOLOGY G310 LOG_ UM_ENG V2 3 TT JSan GENANO 310 OPERATING INSTRUCTION Page 11 Genano Ltd Tel 358 9 7743 870 Kimmeltie 3 Fax 358 9 7743 8711 FIN 02110 ESPOO email info genano fi www genano fi ...

Страница 12: ...vice simply contact the nearest Authorized Genano Service Loca tion It is suggested that for your protection you return shipments of products by insured transport insurance prepaid Damage occurring during shipment is not covered by this warranty NOTE No other warranty written or oral is authorized by Genano Ltd Finland This warranty gives you specific legal rights and you may also have other right...

Страница 13: ...heavily moist atmosphere water or other liquid 4 Do not place or store an air purifier device where it can fall or be pulled over 5 Unplug this air purifier device before moving or transport to another location 6 When discarding material used in this air purifier device follow instructions issued by local au thorities for disposal 7 Ensure that wall socket is grounded 8 Lock the bottom basin when ...

Страница 14: ...t an authorized repair service Red SERVICE ERROR light is continuously on Wait several hours Execute Power wash Reset default program settings Switch the unit OFF and wait about 20 seconds then restart If error continues after resetting contact an authorized repair service Device is leaking water It is possible that device leaks water if transported horizontally Wait 8 hours before first use Check...

Отзывы: