EFN EFB_Rev.01 01-2014
pag. 52
7.6
– USE
-
Press the
key to display the set-point and change it if necessary;
press the
key just once to display the set temperature, which can be changed by pressing and holding
for 3 sec the same key and then using the up and down arrow keys.
-
A manual defrost can be selected; press and hold for 3 sec the
key and if the evaporator temperature is no
higher than +8°C, a manual defrost phase is activated. This phase ends either when the time of 20’ has elapsed
or when the temperature measured by the evaporator sensor is (+8/+5°C Tn/BT). The automatic defrost,
manage
d by the thermostat, takes place once every 8H for a max. of 20’ during which time the readout dEF is
shown on the display.
-
With the keypad active, press keys
and
just once to display the maximum and minimum temperature
respectively, which are recorded by the sensor inside the cabinet. The displayed values are preceded by the
readouts LO and HY respectively. To reset this stored value, press and hold for 3 sec the
key at the
time it is displayed. On the display this reset is preceded by the readout RST (reset).
7.6.1
– SPECIAL USE
-
With the keypad active, press and hold for 3 sec the
key to activate the CONTINUOUS CYCLE phase.
This phase lasts (1H) at a temperature (-2/-21°C TN/BT). These values are factory set in the controller. Unlike
the normal refrigerating phase, in this case the symbol
on the display is lit. When the set time (1H) has
elapsed, the symbol will go out and the appliance will start once again to operate with the previous set point.
7.6.2
– LONG IDLE PERIODS
Turn the machine OFF by pressing
for three seconds, then unplug.
Clean the machine thoroughly (see paragraph 8.2) and make sure the door is left open at the end of the operation and
throughout the idle period.
Содержание EFB/01
Страница 2: ...EFN EFB_Rev 01 01 2014 pag 2...
Страница 7: ...EFN EFB_Rev 01 01 2014 pag 7 1 2 DICHIARAZIONE DI CONFORMITA...
Страница 34: ...EFN EFB_Rev 01 01 2014 pag 34 1 2 DECLARATION OF CONFORMITY...
Страница 61: ...EFN EFB_Rev 01 01 2014 pag 61 1 2 KONFORMIT TSERKL RUNG...
Страница 87: ...EFN EFB_Rev 01 01 2014 pag 87 1 2 D CLARATION DE CONFORMIT...
Страница 112: ...EFN EFB_Rev 01 01 2014 pag 112...
Страница 113: ...EFN EFB_Rev 01 01 2014 pag 113 NOTE...
Страница 114: ...EFN EFB_Rev 01 01 2014 pag 114 NOTE...