8.1 - OPTICAL SIGNALS
This function activates the optical signals (turn indicator flashes) to confirm system arming/disarming
operations.
If the vehicle already has optical lock/unlock signals, the turn indicators alarm flashes
should be disabled.
8.2 - ACOUSTIC SIGNALS
8.3 - PASSIVE ARMING
8.4 - DOOR SWITCH POLARITY SELECTION
This function activates the acoustic signals (siren chirps) to confirm system arming/disarming
operations.
This function arms the system 60 sec. after ignition is switched OFF and the last door is opened and
closed.
will cause the procedure to
interrupt; it will resume once the door is closed
This function modifies the alarm input signal (positive or negative) according to the signal generated
door switch.
Opening a door during the 60-second passive arming countdown
by the
.
!
9.0 - SYSTEM PROGRAMMING EXAMPLE
In both cases, the system will move on to the next function.
Repeat the above steps to enable or disable other functions.
When the last function is programmed, in addition to the confirmation tone, to
the system gives 2 low-pitched chirps, 1 high-pitched chirp and the
turn indicators flash twice.
indicate the end of
the programming procedure,
A quick
a long low pitched chirp and 2 flashes of the turn indicators will confirm the
system is in programming mode.
high-pitched chirp,
Beep
Boop
Press once
to enable the
function.
A quick high-pitched chirp will confirm operation.
The LED will flash according to the selected
BUTTON “ON”
OR
Press once
to disable the
function.
A long low-pitched chirp will confirm operation.
The LED will flash according to the selected
BUTTON “OFF”
DOUBLE PULSE UNLOCK QUICK ACTIVATION:
NB:
- Disconnect the alarm system power supply and ground the Green/Black wire.
- Connect the alarm power supply; 3 quick high-pitched chirps will confirm operation.
- Remove the Green/Black wire from ground.
To reset the default setting, repeat the above steps; 1 low-pitched chirp will confirm the operation.
8.5
If this feature is enabled, 2 unlocking pulses will be supplied to unlock all doors at the same time.
This is useful in case separate actions are required to open the driver door and then the other doors.
- DOUBLE PULSE UNLOCK
To enter in programming mode proceed as follows:
• With the alarm system disarmed, turn ignition key “ON”.
• Wait approx. 2 sec. for the LED to light up.
• While the LED is ON, press remote control button “1”.
Press Gemini remote control button “ON” to enable a programmable function and
button “OFF” to disable it.
ON
OFF
8.0 - SYSTEM PROGRAMMING
The table below applies to the system programmed in “standard configuration”.
Every time you enter in programming mode, the alarm system resets to the default settings.
FUNCTION
STATUS
LED FLASHES
Enabled
Disabled
Disabled
Enabled
Disabled
Arming/disarming optical signals
Arming/disarming acoustic signals
System passive arming
Door input - positive
Double pulse unlock
S
A lack of power during electrical system maintenance, will not affect the programming.