APPENDIX “D” - GEMINI COUNTER/RATE MODE FUNCTION COMMAND CODE SUMMARY
CODE
MODE
DESCRIPTION
COMMENTS
51
OUTPUT ASSIGNMENT
(+) Preset Tracking Disabled
(-) Preset Tracking Enabled
Preset 1 tracks Preset 2
+/-1
Output 1 to Rate A, Output 2 to Counter B
+/-2
Outputs 1 & 2 to Counter B
+/-3
Outputs 1 & 2 to Rate A
Automatically selects code [56,1].
52
OUTPUT 1 TERMINATION MODES
(+) Normal Phase
Output normally “OFF”, turns “ON” at preset.
(-) Reverse Phase*
Output normally “ON”, turns “OFF” at preset.
+/-1
Terminate at Output 2 Start (Gemini 4200 only)
Only available when [51 2]
+/-2
Terminate at Output 2 End (Gemini 4200 only)
Only available when [51 2]
+/-3
Terminate at Manual Reset
+/-4
Terminate at Manual Reset End
+/-5
Terminate after Timed Output 1
+/-6
Boundary
53
TIMED OUTPUT 1 VALUE
Range 0.01 to 599.99 sec.
54
GEMINI 4200 OUTPUT 2 TERMINATION MODES
(+) Normal Phase
Output normally “OFF”, turns “ON” at preset.
(-) Reverse Phase*
Output normally “ON”, turns “OFF” at preset.
+/-1
Terminate at Output 1 Start
Only available when [51 2]
+/-2
Terminate at Output 1 End
Only available when [51 2]
+/-3
Terminate at Manual Reset
+/-4
Terminate at Manual Reset End
+/-5
Terminate after Timed Output 2
+/-6
Boundary
Automatically selects code [56 1]
55
GEMINI 4200 TIMED OUTPUT 2 VALUE
Range 0.01 to 599.99 sec.
56
COUNTER RESET MODES
(+) Maintained
Unit remains reset as long as reset is activated.
(-) Momentary*
Unit will reset instantly and will start counting again
even if reset is still activated.
*
Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.