11. SERIAL COMMUNICATIONS:
Type - Bi-directional 20 mA current loop, 20 mA source provided. (Powers up
to 7 units in a loop with internal current source.)
Baud Rate - Programmable 300 to 2400.
Maximum Address - 16 units.
(Actual number in a single loop is limited by
serial hardware specifications.)
Data Format - 10 bit frame, Odd parity
(one start bit, 7 data bits, one odd
parity bit, and one stop bit.)
Serial Hardware Specifications -
SO - Output Transistor Rating: V
max
= 30 VDC, V
SAT
= 1 V
max
at 20 mA
SI - Input Diode Rating: V
F
= 1.25 V
TYP
; 1.5 V
max
Note: The compliance voltage rating of the source must be greater than the
sum of the voltage drops around the loop.
12. OUTPUT(S):
Solid-State - Current sinking NPN open collector transistors. I
SNK
= 100 mA
max. @ V
CE
= 1 V. V
OH
= 30 VDC max. (Internal Zener diode protection).
Relays - Mounted on a field replaceable PC board. Form C contacts rated at 5
amps @ 120/240 VAC or 28 VDC (resistive load), 1/8 H.P. @ 120 VAC
(inductive load). The operate time is 5 msec nominal and the release time is 3
msec nominal.
Relay Life Expectancy - 100,000 cycles at Max. Rating.
(As load level
decreases, life expectancy increases.)
Programmable Timed Outputs - The timed outputs can be set from 0.01 to
599.99 seconds, ±(0.01% + 10 msec.).
13. CERTIFICATIONS AND COMPLIANCES:
SAFETY
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
for measurement, control, and laboratory use, Part 1.
IP65 Enclosure rating (Face only), IEC 529
Type 4 Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY:
Immunity to EN 50082-2
Electrostatic discharge
EN 61000-4-2 Level 2; 4 Kv contact
1
Level 3; 8 Kv air
Electromagnetic RF fields
EN 61000-4-3 Level 3; 10 V/m
80 MHz - 1 GHz
Fast transients (burst)
EN 61000-4-4 Level 4; 2 Kv I/O
Level 3; 2 Kv power
2
RF conducted interference
EN 61000-4-6 Level 3; 10 V/rms
150 KHz - 80 MHz
Power frequency magnetic fields EN 61000-4-8 Level 4; 30 A/m
Emissions to EN 50081-2
RF interference
EN 55011
Enclosure class A
Power mains class A
Notes:
1. Metal bezel of unit connected with ground from rear bezel screw to
metal mounting panel.
2. When the unit is DC powered, a power line filter (RLC#LFIL0000 or
equivalent) was installed, so as not to impair the function of the unit.
Refer to the EMC Compliance Installation section of the manual for
additional information.
14. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 50°C
Storage Temperature: -40 to 70°C
Operating and Storage Humidity:
85% max. RH (non-condensing) from 0°C to 50°C.
Altitude: Up to 2000 meters
15. CONSTRUCTION:
Metal die-cast bezel, plastic case. This unit is rated for NEMA 4/IP65 indoor
use. Installation Category II, Pollution Degree 2
16. WEIGHT: 2.1 lbs. (0.9 Kg)
DUAL COUNTER MODE [41 2]
MODE
X1
X2
X4
Uni or Bi-directional
9 KHz
4.5 KHz
Anti-Coincidence Add/Subtract
5 KHz
2.5 KHz
Separate Input
7.5 KHz
3.5 KHz
Quadrature
4.5 KHz
4 KHz
2.5 KHz