Installation And User Manual RGB Central Control Panel
V1.5
INSTALLATION
Remove four screws at the corners of the central control panel and open the cover.
You will see
that the electronic card has a connection sockets on it.
1-
1st group light connection socket.
2-
2nd group light connection socket
3-
External timer connection socket (in case of
timer not being used, a jump wire should be used
here)
4-
Satellite panel connection socket
5-
Remote control pairing button
1-2.OUTPUT (Light) Connection
The connection sockets should be removed to connect the 4 light cables correctly and easily.
RGB + signs are located under the sockets and show the colour and energy of the lights to be
connected. Cable connection to the socket must be done properly to the colour cord end terminal
and energy cord end terminal of the lamp.
R :
Red / Should be connected to the red input terminal of the lamp
G :
Green / Should be connected to the green input terminal of the lamp
B :
Blue / Should be connected to the blue input terminal of the lamp.
+ :
+12V DC / Should be connected to the +12V DC input terminal of the lamp.
If the total power of the lamps is higher than 200W, the satellite panel must be used.
3.TIMER INPUT (EXTERNAL TIMER) Connection
An external timer can be connected when the lamps are
required to operate with certain time intervals. The N.O and COM
cord end terminals of the external timer are used. When it
reaches the desired time interval, it turns the contacts off and
switches on the device. In cases when an external timer won’t
be used/connected, this socket must be jumpered with a jump
wire.