Cinterion
®
EHS6 AT Command Set
7.19 AT+CRC
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 157 of 513
7.19
AT+CRC Incoming Call Indication Format
controls the format of the incoming call indication.
Syntax
Unsolicited Result Codes
URC 1
RING
Incoming call indication if
=0.
URC 2
+CRING:
Incoming call indication if
=1.
Parameter Description
[0]
(&F)(P)
Disable extended format.
1
Enable extended format.
Using this mode may lead to connection failures, if the Customer Application
expects URCs in a another format (e.g. set by default).
“REL ASYNC“
Asynchronous non-transparent
“FAX“
Facsimile
Test Command
AT+CRC=?
Response(s)
+CRC:
(list of supported
OK
ERROR
Read Command
AT+CRC?
Response(s)
+CRC:
OK
ERROR
Write Command
AT+CRC=
]
Response(s)
OK
ERROR
PIN
Last
Reference(s)
-
+
-
3GPP TS 27.007
<mode>
(num)(&V)(&W)
<type>
(str)