Cinterion
®
EHS6 AT Command Set
20.5 AT^SSCNT
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 479 of 513
20.5
AT^SSCNT Start and Stop Pulse Counter
The
write command serves to read, start, restart and stop the pulse counter.
Syntax
Unsolicited Result Code
^SSCNT:
The URC applies only to the Start-Stop mode set with
=0. It is delivered once the
pulse counter result was requested with
=2 or the pulse counter was stopped with
=3. The
URC indicates the number of pulses counted.
Parameter Description
This parameter can only be used after configuring the pulse counter with
by using
= 1 to
open pulse counter, otherwise the
read and write command will return error. The
types
0, 1 and 2 apply only to the Start-Stop counter mode set with
0
Reset and start pulse counter from 0.
1
Restart pulse counter and continue counting from the
value of the
last run.
2
Read out current
value.
Test Command
AT^SSCNT=?
Response(s)
^SSCNT:
(list of supported
OK
Read Command
AT^SSCNT?
Response(s)
^SSCNT:
OK
If an error occurs:
ERROR
+CME ERROR:
<err>
Write Command
AT^SSCNT=
Response(s)
If
=0 or 1:
OK
If
=2 or 3:
OK
"
" URC with parameter
If an error occurs:
ERROR
+CME ERROR:
<err>
PIN
Last
-
+
-
<action>
(num)