![Gemalto Cinterion EHS6 Скачать руководство пользователя страница 397](http://html.mh-extra.com/html/gemalto/cinterion-ehs6/cinterion-ehs6_command-manual_2206684397.webp)
Cinterion
®
EHS6 AT Command Set
16.5 AT^SAIC
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 397 of 513
16.5
AT^SAIC Audio Interface Configuration
configures the audio interface. The write command works in all audio modes from 1 to 10.
Syntax
Parameter Description
Input and output selection
1
(P)
Digital input and output
The Digital Audio Interface (DAI) can only be enabled when DAI resources are
available (
="GPIO/mode/DAI","std"). Otherwise the
write
command will respond "+CME ERROR: operation not allowed".
Parameter is mandatory if
0
(P)
Master mode
1
Slave mode
Parameter is mandatory if
=1 (digital).
0
(P)
Long frame
1
Short frame
Test Command
AT^SAIC=?
Response(s)
^SAIC:
(list of supported
s),,,,(list of supported
s), (list of supported
s), (list of
supported
s), (list of supported
OK
Read Command
AT^SAIC?
Response(s)
^SAIC:
,"","","",
,
OK
ERROR
+CME ERROR:
<err>
Write Command
AT^SAIC=
,
Response(s)
OK
ERROR
+CME ERROR:
<err>
PIN
Last
-
+
-
<io>
(num)
<mode>
(num)
<frame_mode>
(num)