BGS2T AT Command Set
4.10 AT^STPB
BGS2T_ATC_V01.301
Page 109 of 554
1/31/12
c
4.10
AT^STPB Transmit Parity Bit (for 7E1 and 7O1 only)
This command is intended only for use with 7E1 and 7O1. In addition to the 7E1 or 7O1 settings made with
specifies whether or not to transmit the parity bit over the air.
Syntax
Command Description
The test command returns the supported values of the parameter
The read command returns the current value of the parameter
The write command can be used to control the handling of the parity bit. If command fails, "+CME ERROR:
unknown" will be returned.
Parameter Description
0
(&F)
The parity bit will not be transmitted over the air and will be replaced with 0.
This mode is the default setting if 7E1 or 7O1 is activated with
.
1
In a data connection 8 bits will be transmitted, including the parity bit, i.e. the
parity bit will be properly transmitted over the air. The setting shall be used if
problems are encountered when BGS2T is running in the default 7E1 or 7O1
mode enabled with
. In this case,
=1 shall be set in addition
to the 7E1 or 7O1 settings selected with
.
Note
•
Command is usable if multiplexer is enabled but setting is ignored.
Test Command
AT^STPB=?
Response(s)
^STPB:
(list of supported
OK
Read Command
AT^STPB?
Response(s)
^STPB:
OK
Write Command
AT^STPB=
Response(s)
OK
ERROR
+CME ERROR:
PIN ASC0 MUX1 MUX2 MUX3
Last
-
+
±
±
±
-
-
<n>
(num)(&W)
Confidential / Released